Gas Connection - Wolf ICBCG15 Installation Instructions Manual

Table of Contents

Advertisement

I N S TA L L AT I O N
I N S T R U C T I O N S
I N S TA L L AT I O N
O P T I O N S
M U LT I P L E C O O K T O P I N S TA L L AT I O N
If the gas cooktop is to be used with any
combination of additional cooktop units or
modules with a filler strip, the cut-out width is
calculated by adding the corresponding units'
cut-out dimensions plus 32 mm for each addi-
tional unit. Refer to the illustration below.
M U L T I P L E U N I T I N S T A L L A T I O N
IMPORTANT NOTE: When multiple units are
installed side by side, each unit must have its
own separate recommended electrical circuit.
When two or more modules are installed
together, an integrated module filler strip
(IFILLER/S) is recommended. Contact your
Wolf dealer for information on these accessory
components.
1518 mm - FOUR MODULES WIDTH OR
1511 mm - 762 mm COOKTOP AND TWO MODULES OR
1276 mm - 914 mm COOKTOP AND ONE MODULE
1130 mm - THREE MODULES WIDTH OR
1124 mm - 762 mm COOKTOP AND ONE MODULE
743 mm
TWO MODULES WIDTH
356 mm
CUT-OUT
495 mm
WIDTH
CUT-OUT
DEPTH
64 mm
FRONT OF COUNTERTOP
Countertop cut-out dimensions for installation of multiple cooktops
O P T I O N A L
I N S T A L L A T I O N S
Dimensions will vary
according to the specific
installation.

Gas connection:

The cooktop is adjusted to operate on
the gas type specified on the gas type
label located on the bottom of the unit.
If in doubt as to the type of gas avail-
able contact the network operator or gas
supplier for confirmation of gas type.
The cooktop
must be
connected to
the gas supply
with upstream
connection of
an isolation
valve in accor-
dance with the
respectively
valid regulations. We recommend that
the isolation valve be fitted prior to the
cooktop to enable isolation of the
cooktop from the gas supply. The valve
must be easily accessible at all times.
This appliance may be connected with a
hose assembly, class B or class D. If
connected with a hose assembly ensure
that the gas supply connection point is
accessible with the appliance installed.
The hose assembly must be as short as practical
and comply with relevent AS/NZ5601 requirements.
The hose must not be kinked, subjected to abrasion
or permanently deformed. The hose must not be near
of a metal hotplate, flue or underbench oven etc.
or in contact with any hot surfaces;; such as the base
The position of the inlet connection is
measured from bottom RH rear of unit,
50 mm centre line from rear and 65 mm
centre line from RH side.