Technical Data

Symbol ........................................................4000 counts
Measuring rate ............................................Approx. 3 measuring operations/second
measuring line length ..................................Approx. 80 cm each
Measuring impedance ................................>10MΩ (V range)
Operating voltage ........................................9V block battery
Working conditions ......................................0 - 40°C (<70%rF)
Operating altitude ........................................max. 3,000 m
Storage temperature....................................-10°C to +60°C (<80%rF)
Weight ........................................................approx. 335 g
Dimensions (LxWxH) ..................................170 x 78 x 48 (mm)
Over-voltage category ................................CAT III 600 V, Impurity level 2
Measurement tolerances
Statement of accuracy in ± (% of reading + display error in counts (= number of smallest points)). The accu-
racy is valid for one year at a temperature of +23°C ± 5°C, and at a relative humidity of less than 70 %, non-
condensing.
Direct voltage (DC)
Range
400 mV
4 V
40 V
400 V
600 V
Other Features
Alternate voltage (AC)
Range
400 mV
4 V
40 V
400 V
600 V
Other Features
60
Resolution:
0.001 V
Overload protection 600 V
Resolution:
0.001 V
Frequency range 50 – 400 Hz;
Effective average value with sinus voltage;
overload protection 600 V
400 mV area only through manual area selection!
Accuracy
0.1 mV
±(1,2 % + 5)
0.01 V
0.1 V
±(1,8% + 4)
1 V
Accuracy
0.1 mV
±(1,8% + 20)
±(1,2% + 5)
0.01 V
0.1 V
±(1,8% + 4)
1 V
±(2,2% + 5)