Amp Check - Yamaha RX-V620 Service Manual

Hide thumbs Also See for RX-V620:
Table of Contents

Advertisement

AMP CHECK

Confirmation of Idling Current
1) No signal applied.
2) Non-loaded condition.
3) Aging is not neccessary.
Test Point
Item
MAIN L
R145
MAIN R
R150
R165
CENTER
0.1mV—10mV
R155
REAR L
R160
REAR R
*
Confirm that the idling current is 0.2mV — 15mV after 60 minutes.
Note)
If R105(L ch), R112(R ch), R133(C ch), R119(RL ch) or R126(RR ch) have already been
cut off and idling current does not flow, reconnect R105(1kΩ), R112(1kΩ), R133(1kΩ),
R119(1kΩ) or R126(1kΩ).
Q101, Q102, Q103, Q104 and Q105 are transistors for temperature correction. Apply silicone
grease to the contact surface with the heat sink.
Test Point
Rating (DC)
If the measured voltage exceeds 10.1mV, cut
the lead wire of R105(L ch), R112(R ch),
R133(C ch), R119(RL ch) or R126(RR ch) and
then check again if each measured value
satisfies the rating.
0.1mV — 10mV (DC)
R145 (L ch)
R150 (R ch)
R165 (C ch)
RX-V620/HTR-5460/RX-V620RDS
Note
0.1mV — 10mV (DC)
R155 (RL ch)
R160 (RR ch)
Cut OFF
R105 (L ch)/R112 (R ch)/
R133 (C ch)/R119 (RL ch)/
R126 (RR ch)
MAIN [1] P.C.B.
30

Advertisement

Table of Contents
loading

This manual is also suitable for:

Htr-5460Rx-v620rds

Table of Contents