• Please use approved power cord and production number of the product. provided by Philips all the time. If your power cord is missing, please contact with your local service 1.1 Safety precautions and center.
Page 4
1. Important be better than a 15-minute break not expose the monitor to dust, every two hours. Try to keep your rain, water, or excessive moisture eyes from eye strain while using the environment. screen for a constant period of time • If your monitor gets wet, wipe it with by : dry cloth as soon as possible.
1. Important Warning 1.2 Notational Descriptions Failure to activate a screen saver, or The following subsections describe a periodic screen refresh application notational conventions used in this may result in severe “burn-in” or “after- document. image” or “ghost image” symptoms that will not disappear and cannot be Notes, Cautions and Warnings repaired.
From the planning, design and production stages, Philips emphasizes the important of making products that can easily be recycled. At Philips, end- of-life management primarily entails This marking on the product or on participation in national take-back...
Top Victory Investments Ltd., and Top Victory Investments Ltd. is the warrantor in relation to this product. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V. and are used under license.
Page 8
2. Setting up the monitor Connecting to your PC USB hub Fast Charger USB AB Kensington anti-theft lock Note Display port input USB 2.4Ghz wireless devices, such as, wireless mouse, keyboard, DVI input and headphones, maybe have HDMI input interference by the high-speed signal of USB 3.1 devices, which may result VGA input in a decreased efficiency of the radio...
What is On-Screen Display (OSD)? Description of the control buttons On-Screen Display (OSD) is a feature in all Philips LCD monitors. It allows an end user to adjust screen performance or select functions of the monitors directly through an on-screen instruction window.
Page 10
2. Setting up the monitor The OSD Menu Resolution notification Below is an overall view of the structure This monitor is designed for optimal of the On-Screen Display. You can use performance at its native resolution, this as a reference when you want to 1920 ×...
2. Setting up the monitor Height adjustment 2.3 Remove the Base Assembly for VESA Mounting Before you start disassembling the monitor base, please follow the instructions below to avoid any possible damage or injury. 1. Extend the monitor base to its maximum height.
Page 12
2. Setting up the monitor Note This monitor accepts a 100mm x 100mm VESA-Compliant mounting interface. VESA Mounting Screw M4. Always contact manufacturer for wall-mount installation. 100mm 100mm...
EasyRead, Office, Photo, Movie, Game, How does it work? Economy, LowBlue Mode and Off. SmartImage is an exclusive, leading edge Philips technology that analyzes the content displayed on your screen. Based on a scenario you select, SmartImage dynamically enhances the contrast, color saturation and sharpness ...
Page 14
Developed for wellbeing, temperature of the monitor. Philips LowBlue Mode setting uses a smart software technology to • Office: Enhances text and dampens reduce harmful shortwave blue brightness to increase readability light.
3. Image Optimization 3.2 SmartContrast What is it? Unique technology that dynamically analyzes displayed content and automatically optimizes a Monitor's contrast ratio for maximum visual clarity and viewing enjoyment, stepping up backlighting for clearer, crisper and brighter images or dimming backlighting for clear display of images on dark backgrounds.
4. PowerSensor™ detection signal for distances up to 4. PowerSensor™ 120 cm or 47 inches. (Setting 4) • Since some dark colored clothing How does it work? tends to absorb infrared signals even when the user is within 100 cm • PowerSensor works on principle or 40 inches of the display, step up of transmission and reception of...
Page 17
4. PowerSensor™ Note A manually selected PowerSensor mode will remain operational unless and until it is readjusted or the default mode is recalled. If you find that the PowerSensor is excessively sensitive to nearby motion for some reason, please adjust to a lower signal strength. Keep sensor lens clean, if the sensor lens is dirty, wipe it with alcohol to avoid reducing of distance detection .
5.Technical Specifications 5. Technical Specifications Picture/Display Monitor panel type IPS Technology Backlight Panel size 25" W (63.4 cm) Aspect ratio 16:10 Optimum resolution 1920 x 1200 @ 60 Hz Contrast Ratio (typ.) 1,000:1 Pixel Pitch 0.279(H) mm x 0.282(V) mm Viewing angle 178°...
Page 19
5.Technical Specifications Power AC Input AC Input AC Input Consumption Voltage at Voltage at Voltage at 100VAC , 60Hz 115VAC , 60Hz 230VAC, 50Hz Normal operation 25.63W (typ.) 25.47W (typ.) 25.27W (typ.) Sleep (standby) <0.5W <0.5W <0.5W <0.3W <0.3W <0.3W Off (AC switch) AC Input AC Input...
Page 20
5.Technical Specifications Environmental and energy ROHS Packaging 100% recyclable Specific substances 100% PVC BFR free housing Cabinet Color Black Finish Texture Note This data is subject to change without notice. Go to www.philips.com/support to download the latest version of leaflet.
6.Power Management 6. Power Management If you have VESA DPM compliance display card or software installed in your PC, the monitor can automatically reduce its power consumption when not in use. If an input from a keyboard, mouse or other input device is detected, the monitor will 'wake up' automatically.
Pixel Defect Policy single black pixel. Other combinations of lit and dark sub pixels appear as Philips strives to deliver the highest single pixels of other colors. quality products. We use some of the industry's most advanced...
Page 24
Proximity of Pixel Defects Because pixel and sub pixels defects of the same type that are near to one another may be more noticeable, Philips also specifies tolerances for the proximity of pixel defects. Three adjacent lit sub pixels (one white pixel).
Page 25
In order to qualify for repair or replacement due to pixel defects during the warranty period, a TFT Monitor panel in a Philips flat panel monitor must have pixel or sub pixel defects exceeding the tolerances listed in the following tables.
Please contact our Philips Customer Service Representative or local contact center (by Consumer care number) for more details. Philips Customer Care Center number listed below.
• Disconnect the monitor from mains • First, ensure that the power button power source immediately for safety on the front of the monitor is in the • Contact with Philips customer OFF position, then press it to the service representative immediately. ON position.
Page 28
Service contact information listed in may cause "burn in", also known as Important information manual and "after-imaging " or "ghost imaging", contact Philips customer service on your screen. "Burn-in", "after- representative. imaging", or "ghost imaging" is a * Functionality different according to well-known phenomenon in LCD display.
• Shut down your computer, that the panel surface is not disconnect your old monitor and subjected to excessive shocks reconnect your Philips LCD monitor. and is protected from sharp or blunt objects. When handling the • Turn on your monitor and then turn monitor, make sure that there is on your PC.
Page 30
Can I connect my LCD monitor to image” or “ghost image” symptoms any PC, workstation or Mac? that will not disappear and cannot be Ans.: Yes. All Philips LCD monitors are repaired. The damage mentioned above fully compatible with standard is not covered under your warranty.
Page 31
“Attention” to show the unlock/lock status as shown below illustrators. Monitor control unlocked Monitor controls locked Q14: Where can I find Important Information manual mentioned in EDFU? Ans.: Important Information manual can be download on the Philips website support page.
Page 32
This product has been manufactured by and is sold under the responsibility of Top Victory Investments Ltd., and Top Victory Investments Ltd. is the warrantor in relation to this product. Philips and the Philips Shield Emblem are regis- tered trademarks of Koninklijke Philips N.V. and are used under license.
Need help?
Do you have a question about the 252B9/01 and is the answer not in the manual?
Questions and answers