Arcoaire A Series Installation, Start-Up, Operating And Service And Maintenance Instructions page 13

Single stage, multi-speed ecm, non–condensing gas furnace input capacities: 45,000 thru 155,000 btuh
Table of Contents

Advertisement

N80ESN/N80ESL(Series A): Installation, Start–Up, Operating and Service and Maintenance Instructions
Wire Lead
Furnace
Color
Gray
Blue
1102420
Yellow
Orange
Red
Gray
Blue
1352420
Yellow
Orange
Red
Gray
Blue
1552420
Yellow
Orange
Red
1. A filter is required for each return-air inlet. Airflow performance included 3/4-in. (19 mm) washable filter (see accessory list). To determine airflow performance without this filter, assume an
additional 0.1 In. W.C. available external static pressure.
2. Adjust the blower speed tabs as necessary for the proper air temperature rise for each installation.
3. -- Indicates unstable operating conditions.
4. If the same motor speed tap is needed for heating and cooling, a Jumper Wire accessory kit is available. (See Specification sheet for the current Jumper Wire accessory part number). See
Function column for applicable limitations.
33 1/3
[845.9]
NOTES:
1. Two additional 7/8-in. (22 mm) diameter holes are located in the top plate.
2. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer's recommendations for equivalent diameters.
a. For 800 CFM-16-in. (406 mm) round or 14 1/2 x 12-in. (368 x 305 mm) rectangle.
b. For 1200 CFM-20-in. (508 mm) round or 14 1/2 x 19 1/2-in. (368 x 495 mm) rectangle.
c. For 1600 CFM-22-in. (559 mm) round or 14 1/2 x 22 1/16-in. (368 x 560mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Specification Sheet literature for specific use of single side inlets. The use of both side inlets, a combination of 1
side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Table 4 – Air Delivery - CFM (With Filter)* (Continued)
Function
Cooling. Do not use for heating.
Heating or alt Cooling
Alt Cooling or alt Heating
Alt Cooling. Do not use for heating.
Alt Cooling. Do not use for heating.
Cooling. Do not use for heating.
Heating or alt Cooling
Alt Cooling or alt Heating
Alt Cooling. Do not use for heating.
Alt Cooling. Do not use for heating.
Cooling. Do not use for heating.
Heating or alt Cooling
Alt Cooling or alt Heating
Alt Cooling. Do not use for heating.
Alt Cooling. Do not use for heating.
Fig. 17 – Dimensional Drawing
Test Airflow Delivery @ Various External Static Pressures
0.1
0.2
0.3
0.4
2250
2190
2130
2070
1995
1930
1865
1800
1540
1460
1385
1305
1345
1195
1135
1055
1335
1075
965
890
2065
2005
1940
1875
1825
1760
1695
1630
1760
1690
1625
1555
1620
1550
1480
1405
1325
1260
1185
1100
2205
2150
2090
2030
2055
1995
1935
1875
1860
1795
1730
1670
1495
1430
1355
1285
1295
1085
1000
910
13
0.5
0.6
0.7
0.8
2005
1950
1885
1820
1740
1670
1605
1535
1235
1165
1095
1035
980
920
845
770
820
735
660
580
1810
1740
1670
1600
1560
1490
1420
1350
1485
1415
1345
1275
1335
1260
1195
1130
1025
955
885
805
1965
1905
1840
1780
1810
1750
1690
1615
1605
1540
1470
1395
1210
1130
1065
995
835
765
670
600
0.9
1
1755
1685
1465
1400
955
890
695
620
505
440
1530
1470
1275
1205
1200
1130
1065
995
735
670
1710
1645
1540
1460
1320
1250
930
850
530
465
A190084