Clear Data Mode Serial Port Driver; Restart System - 4xem IPVS1A User Manual

4xem ipvs1a video servers: user manual
Hide thumbs Also See for IPVS1A:
Table of Contents

Advertisement

Clear data mode serial port driver

This URL applies to the attached serial port device including supported PTZ cameras or
non-supported custom cameras. Note the serial port settings of custom cameras must be correctly
defined in advance.
Send command to device attached to COM
/cgi-bin/senddata.cgi?data=123456,ABCDEF&flush=yes&wait=1000&read=6
This hyperlink will inform Video Server to send out binary format commands to the COM with
"0x12, 0x34, 0x56" followed by "0xAB, 0xCD, 0xEF". Each comma separates the commands by
200 milliseconds. "flush=yes" means the receive data buffer of COM port must be cleared before
read. Then read 6 bytes after waiting for 1000 milliseconds. The read data can be up to 128 bytes
and will return as ASCII coded hexadecimal value, e.g., 0x41, 0x42, 0x43 read from COM port
will show in returned homepage as 414243 instead of ABC.
Restore factory default settings
/setup/restore.cgi
Video Server will automatically restart after restoring factory default configurations.

Restart system

/setup/reset.cgi
Restart Video Server without warning.