Page 3
Basic Safety Instructions Always read through and comply with the following safety instructions! All plants and locations of the Rohde & Schwarz group of companies make every effort to keep the safety standards of our products up to date and to offer our customers the highest possible degree of safety. Our products and the auxiliary equipment they require are designed, built and tested in accordance with the safety standards that apply in each case.
Page 4
Basic Safety Instructions Symbol Meaning Symbol Meaning Caution ! Hot surface Alternating current (AC) Protective conductor terminal Direct/alternating current (DC/AC) To identify any terminal which is intended for connection to an external conductor for protection against electric shock in case of a fault, or the terminal of a protective earth Earth (Ground) Class II Equipment...
Page 5
Basic Safety Instructions Operating states and operating positions The product may be operated only under the operating conditions and in the positions specified by the manufacturer, without the product's ventilation being obstructed. If the manufacturer's specifications are not observed, this can result in electric shock, fire and/or serious personal injury or death. Applicable local or national safety regulations and rules for the prevention of accidents must be observed in all work performed.
Page 6
Basic Safety Instructions 6. The product may be operated only from TN/TT supply networks fuse-protected with max. 16 A (higher fuse only after consulting with the Rohde & Schwarz group of companies). 7. Do not insert the plug into sockets that are dusty or dirty. Insert the plug firmly and all the way into the socket provided for this purpose.
Page 7
Basic Safety Instructions 2. Before you move or transport the product, read and observe the section titled "Transport". 3. As with all industrially manufactured goods, the use of substances that induce an allergic reaction (allergens) such as nickel cannot be generally excluded. If you develop an allergic reaction (such as a skin rash, frequent sneezing, red eyes or respiratory difficulties) when using a Rohde &...
Page 8
Basic Safety Instructions 2. Adjustments, replacement of parts, maintenance and repair may be performed only by electrical experts authorized by Rohde & Schwarz. Only original parts may be used for replacing parts relevant to safety (e.g. power switches, power transformers, fuses). A safety test must always be performed after parts relevant to safety have been replaced (visual inspection, protective conductor test, insulation resistance measurement, leakage current measurement, functional test).
Page 9
Basic Safety Instructions 3. If you use the product in a vehicle, it is the sole responsibility of the driver to drive the vehicle safely and properly. The manufacturer assumes no responsibility for accidents or collisions. Never use the product in a moving vehicle if doing so could distract the driver of the vehicle. Adequately secure the product in the vehicle to prevent injuries or other damage in the event of an accident.
Page 10
Instrucciones de seguridad elementales Instrucciones de seguridad elementales ¡Es imprescindible leer y cumplir las siguientes instrucciones e informaciones de seguridad! El principio del grupo de empresas Rohde & Schwarz consiste en tener nuestros productos siempre al día con los estándares de seguridad y de ofrecer a nuestros clientes el máximo grado de seguridad. Nuestros productos y todos los equipos adicionales son siempre fabricados y examinados según las normas de seguridad vigentes.
Page 11
Instrucciones de seguridad elementales Señalización de seguridad de los productos Las siguientes señales de seguridad se utilizan en los productos para advertir sobre riesgos y peligros. Símbolo Significado Símbolo Significado Aviso: punto de peligro general Tensión de alimentación de PUESTA EN MARCHA / PARADA Observar la documentación del producto Atención en el manejo de dispositivos de peso...
Page 12
Instrucciones de seguridad elementales Palabras de señal y su significado En la documentación del producto se utilizan las siguientes palabras de señal con el fin de advertir contra riesgos y peligros. Indica una situación de peligro que, si no se evita, causa lesiones graves o incluso la muerte.
Page 13
Instrucciones de seguridad elementales Seguridad eléctrica Si no se siguen (o se siguen de modo insuficiente) las indicaciones del fabricante en cuanto a seguridad eléctrica, pueden producirse choques eléctricos, incendios y/o lesiones graves con posible consecuencia de muerte. 1. Antes de la puesta en marcha del producto se deberá comprobar siempre que la tensión preseleccionada en el producto coincida con la de la red de alimentación eléctrica.
Page 14
Instrucciones de seguridad elementales 11. A menos que esté permitido expresamente, no retire nunca la tapa ni componentes de la carcasa mientras el producto esté en servicio. Esto pone a descubierto los cables y componentes eléctricos y puede causar lesiones, fuego o daños en el producto. 12.
Page 15
Instrucciones de seguridad elementales 5. Ciertos productos, como p. ej. las instalaciones de radiocomunicación RF, pueden a causa de su función natural, emitir una radiación electromagnética aumentada. Deben tomarse todas las medidas necesarias para la protección de las mujeres embarazadas. También las personas con marcapasos pueden correr peligro a causa de la radiación electromagnética.
Page 16
Instrucciones de seguridad elementales Baterías y acumuladores o celdas Si no se siguen (o se siguen de modo insuficiente) las indicaciones en cuanto a las baterías y acumuladores o celdas, pueden producirse explosiones, incendios y/o lesiones graves con posible consecuencia de muerte. El manejo de baterías y acumuladores con electrolitos alcalinos (p. ej. celdas de litio) debe seguir el estándar EN 62133.
Page 17
Instrucciones de seguridad elementales Eliminación/protección del medio ambiente 1. Los dispositivos marcados contienen una batería o un acumulador que no se debe desechar con los residuos domésticos sin clasificar, sino que debe ser recogido por separado. La eliminación se debe efectuar exclusivamente a través de un punto de recogida apropiado o del servicio de atención al cliente de Rohde &...
Page 18
Customer Support Technical support – where and when you need it For quick, expert help with any Rohde & Schwarz equipment, contact one of our Customer Support Centers. A team of highly qualified engineers provides telephone support and will work with you to find a solution to your query on any aspect of the operation, programming or applications of Rohde &...
® Contents R&S TS-PIO3B Contents 1 Introduction.................... 7 General...........................7 Overview........................7 2 R&S TS-PIO3B..................10 General.........................10 Features........................10 View..........................10 Block Diagram and Mechanical Layout..............11 Display Elements of the Module................11 Functional Description....................12 2.6.1 Open Drain I/O Ports.....................12 2.6.2 TTL Port........................
Page 20
Mechanical Layout...................... 40 Display Elements of the Module................40 Functional Description....................41 5.7.1 Wiring of the open drain I/O ports and the analogue inputs of the R&S TS-PIO3B..41 5.7.2 Function of port P9.TIO of the R&S TS-PIO3B............. 43 5.7.3 SPI..........................
Page 22
Parallel Adapter Identification via Ports................ 70 7.2.2 Serial Adapter Identification via SPI-EEPROM............. 71 8 Installation of the Modules..............72 Installation of R&S TS-PIO3B and R&S TS-PTR............72 Installation of the R&S TS-PRIO4................73 Installation of the R&S TS-PTRF................73 Installation of the R&S TS-PXM1................74 9 Software....................
The present operating instructions provide all the information required for installing, programming and operating the following modules in the Test System Versatile Plat- form R&S CompactTSVP or R&S PowerTSVP: ● Digital I/O Module R&S TS-PIO3B ● Signal Transmission Module R&S TS-PTR ●...
Page 24
● Requires R&S TS-PIO3B or R&S TS-PTR Rear Transmission Module R&S TS-PRIO4 ● Routing of three 8-bit ports of the R&S TS-PIO3B to the TSVP rear panel. ● Requires R&S TS-PIO3B or R&S TS-PTR Switching Extension Module R&S TS-PXM1 ●...
Page 25
® Introduction R&S TS-PIO3B Overview Rear Slot A4 Rear Connector Analogbus Backplane Figure 1-1: Example configuration of the modules in an R&S TSVP User Manual 1512.3523.12 ─ 06...
2 R&S TS-PIO3B 2.1 General The Digital I/O Module R&S TS-PIO3B is a plug-in card for CAN slots of the R&S Com- pactTSVP or R&S PowerTSVP. The module provides digital, quasi-bidirectional lines, a TTL port, analog inputs, SPI signals and supply voltages. All the I/O signals are refer- enced to earth.
Figure 2-1: View of the Digital I/O Module R&S TS-PIO3B 2.4 Block Diagram and Mechanical Layout The R&S TS-PIO3B module is designed as a short plug-in card for installation on the front of the R&S CompactTSVP or R&S PowerTSVP test platforms. The X10 connector on the front either serves for the direct connection of devices under test or for connect- ing the R&S TS-PTRF adapter module.
® R&S TS-PIO3B R&S TS-PIO3B Functional Description 2.6 Functional Description 2.6.1 Open Drain I/O Ports Ports 0 – 7 (variant 02) and ports 0 – 4 (variant 04) have a width of 8 bits each and are wired at the pin as follows: Figure 2-3: Wiring of the open drain I/O ports The FET shown is integrated into a Texas Instruments TPIC6A595 chip.
® R&S TS-PIO3B R&S TS-PIO3B Functional Description ViInt32 port, ViPUInt8 pattern); Ports 5, 6 and 7 are not only available at X10 on the front but at the same time at X20 and thus connected to the backplane. Via the R&S TS-PXB2 or R&S TS-PRIO4 options, these ports can be routed to the rear panel of the R&S CompactTSVP or R&S...
® R&S TS-PIO3B R&S TS-PIO3B Functional Description If an R&S TS-PRTF is plugged into X10, port 9 is no longer available. In this case, port 9 is used internally for generating various signals for controlling the R&S TS-PTRF. The following function call writes port 9 (in this case, the parameter port must be set to...
MISO is read in as 0x69. Figure 2-6: Basic SPI cycle (8 bits) When a R&S TS-PTRF is connected to a R&S TS-PIO3B, the generation of an exter- nal Chip Select signal for SPI accesses is handled by the R&S TS-PTRF. This function- ality is described in chapter 7: Application Examples.
ViInt32 port); 2.6.5 Voltage Sources The R&S TS-PIO3B module provides +5 V and +12 V on X10. The voltages are fused through SMD slow-blowing fuses with a nominal value of 2 A /. Replace the fuses with fuses of the same type. Never bridge the fuses with a wire.
Page 33
® R&S TS-PIO3B R&S TS-PIO3B Functional Description Table 2-4: Fuse F3 Signal on the backplane Jumper X2 Fuse Signal on the X10 connec- tor on the front X20.D19 AUX2 X2.1 X2.2 X10.C28 AUX2 X20.A20 X10.B29 X1.B1 -12V_IN X2.3 X20.A19 Figure 2-7 shows the jumpers' position and default settings.
® R&S TS-PIO3B R&S TS-PIO3B Functional Description Figure 2-8: Position of fuses 2.6.6 Other Interface Signals CFG_AIN, AUX1, AUX2: Do not connect anything to these signals. They are for inter- nal use. CHA_GND: Chassis Ground: This pin is connected to the chassis earth.
The Signal Transmission Module R&S TS-PTR is a passive adapter module for routing signals through the TSVP. The module is mechanically compatible to the Digital I/O Module R&S TS-PIO3B. To route the signals to the rear panel, for installation in slots A1 and A2, a R&S TS- PXB2 module and for installation in slots 3-14 a Rear Transmission Module R&S TS-...
® R&S TS-PTR R&S TS-PIO3B Functional Description 3.4 Block Diagram and Mechanical Layout The R&S TS-PTR module is designed as a short plug-in card (approx. 160 x 100 mm) for installation on the front of the R&S CompactTSVP or R&S PowerTSVP test plat- forms.
® R&S TS-PTR R&S TS-PIO3B Interface Description 3.6.2 Voltage Sources The R&S TS-PTR module provides +5 V and +12 V on X10. The voltages are fused through SMD slow-blowing fuses with a nominal value of 2 A. Replace the fuses with fuses of the same type. Never bridge the fuses with a wire.
The Rear Transmission Module R&S TS-PRIO4 is a passive adapter module for the rear I/O range for routing signals from a Digital I/O Module R&S TS-PIO3B or a Signal Transmission Module R&S TS-PTR to the rear panel of the R&S CompactTSVP or R&S PowerTSVP.
® R&S TS-PRIO4 R&S TS-PIO3B Functional Description 4.4 Block Diagram and Mechanical Layout Figure 4-2 shows the simplified diagram and the mechanical structure of the R&S TS- PRIO4 module. X401 X202 Figure 4-2: Simplified diagram and mechanical structure of the R&S TS-PRIO4 module 4.5 Display Elements of the Module...
® R&S TS-PRIO4 R&S TS-PIO3B Interface Description Signal Signal P7.IO6 P7.IO7 4.7.3 Jumpers The jumpers on the module have been correctly configured ex works. They must not be changed. The delivery status is described in the following. X401 X201 8-10...
5.2 Features Wiring of the 8 open drain I/O ports of the R&S TS-PIO3B on 8 connectors (X33 – X40) Optional wiring (via jumpers X1-X3 and X5-X9) of the 8 open drain ports of the R&S TS-PIO3B to the front panel Optional wiring (via jumpers, X4) of the 8 analogue inputs of the R&S TS-PIO3B to the front panel...
5.6 Display Elements of the Module There are three LEDs (light-emitting diodes) on the front of the Port Transmission Mod- ule R&S TS-PTRF. These LEDs indicate the actual status of the R&S TS-PIO3B con- nected to the R&S TS-PTRF. Description of the LEDs:...
The Port Transmission Module R&S TS-PTRF contacts each of the open drain I/O ports (0-7) of the connected R&S TS-PIO3B to exactly one of the connectors X33 to X40. In addition, each of the open drain I/O ports of the R&S TS-PIO3B can optionally be wired to the front panel via jumpers.
Page 58
5-4, the R&S TS-PTRF features a jumper to the front panel for each bit of an open drain I/O port or of the analogue port of the R&S TS-PIO3B. If a complete port is to be wired to the front panel, 8 jumpers must be plugged.
The R&S TS-PTRF generates eight SPI Chip Select signals (low active) from the R&S TS-PIO3B port P9.TIO. One CS signal each is wired to X33 to X40 and can be routed in parallel to the front panel (X10) via a jumper.
The 5-V converter can deliver a max. output current of 2 A. The +12 V are fused on the R&S TS-PIO3B / R&S TS-PTR by fuses. The +5 V gener- ated locally are not fused.
Page 61
® R&S TS-PTRF R&S TS-PIO3B Interface Description a b c Figure 5-6: R&S TS-PTRF X10 connector (view: plug-in side) Table 5-4: R&S TS-PTRF, assignment of the X10 connector EXT_P0.IO0 EXT_P5.IO0 EXT_P3.IO0 EXT_P0.IO1 EXT_P5.IO1 EXT_P3.IO1 EXT_P0.IO2 EXT_P5.IO2 EXT_P3.IO2 EXT_P0.IO3 EXT_P5.IO3 EXT_P3.IO3 EXT_P0.IO4...
® R&S TS-PTRF R&S TS-PIO3B Interface Description Table 5-17: R&S TS-PTRF, assignment of the X4 connector EXT_P10. AIN 0 P10. AIN 0 EXT_P10. AIN 1 P10. AIN 1 EXT_P10. AIN 2 P10. AIN 2 EXT_P10. AIN 3 P10. AIN 3 EXT_P10.
8 groups of 4 switches each. Control is implemented via a Port Transmission Module R&S TS-PTRF and a Digital I/O Module R&S TS-PIO3B. All the switching contacts are available on the X10 front connector, the common contacts of the switches are additionally available on connectors.
® R&S TS-PXM1 R&S TS-PIO3B Block Diagram 6.4 Block Diagram Figure 6-2 shows the function block diagram of the Switching Extension Module R&S TS-PXM1. Figure 6-2: Function block diagram of the R&S TS-PXM1 Figure 6-3 shows a relay module in detail.
® R&S TS-PXM1 R&S TS-PIO3B Display Elements of the Module Control EEPROM Figure 6-4: Mechanical Layout of the R&S TS-PXM1 6.6 Display Elements of the Module There are three LEDs (light-emitting diodes) on the front of the R&S TS-PXM1 module.
® R&S TS-PXM1 R&S TS-PIO3B Functional Description 6.7 Functional Description 6.7.1 Relay Wiring The R&S TS-PXM1 module comprises 16 relays with two switches each. Two relays are always served by one control bit, which results in one 4-pin switch per bit (4PDT).
Interface Description 6.7.2 EEPROM The EEPROM available on module R&S TS-PXM1 can be read out via the SPI bus, e.g. by the R&S TS-PIO3B. The EEPROM contains identification data (identification number, change status, serial number etc.). 6.8 Interface Description 6.8.1 X10 Connector on the Front...
R&S TS-PIO3B into the external circuit. 7.2 Adapter Identification The ports of the R&S TS-PIO3B may be used, e.g. to detect an externally connected test adapter. Two different options are shown in this context.
(only if the EEPROM is connected to an R&S TS-PTRF). rspio3b_PtrfSelectPort (..) Very different types of EEPROMs can be used. Due to its universal software, the R&S TS-PIO3B can serve all the SPI EEPROMs that can handle SPI mode 0. User Manual 1512.3523.12 ─ 06...
TS-PIO3B Installation of the R&S TS-PTRF The R&S TS-PIO3B module is plugged especially tightly into slots 3 – 14 of the Com- pactTSVP. Caution! Do not jerk to pull it out. To prevent injuries, it is recommended to wear gloves.
Installation of the Modules R&S TS-PIO3B Installation of the R&S TS-PXM1 ● Ensure that the removal cord of the R&S TS-PIO3B or R&S TS-PTR is not between the connectors. ● Push in the R&S TS-PTRF module using moderate force. ●...
9 Software 9.1 Driver Software An IVI-C driver is available for the functions of the R&S TS-PIO3B digital I/O module. The driver is part of the ROHDE & SCHWARZ GTSL software. All the functions of the driver are documented comprehensively in the online Help and in the LabWindows/CVI Function Panels.
® Software R&S TS-PIO3B Sample Programs Figure 9-1: R&S TS-PIO3B soft panel The operation of the soft panel is described in chapter 13 of the "Software Description of the R&S GTSL". 9.3 Sample Programs 9.3.1 Programming with DIOMGR Error handling is not considered in this sample in order to keep it easy to read.
9.3.2 Programming with Signal Routing Library /* Programming example with signal routing library The following configuration files are used in this example: physical.ini ------------ [device->PIO3B_13] Description = "TS-PIO3B, Digital IO Module, Slot 13" Type = PIO3B ResourceDesc = CAN0::0::1::13 DriverDll = rspio3b.dll DriverPrefix = rspio3b DriverOption = "Simulate=0,RangeCheck=1"...
® Software R&S TS-PIO3B Sample Programs /* disconnect power supply; wait time is specified in switch command */ if ( ! errorOccurred ) ROUTE_Execute (0, residRoute, "#DISCONNECT_PS", &errorOccurred, &errorCode, errorMessage); cs("ROUTE_Execute"); 9.3.3 Programming with Device Drivers Error handling is not considered in this sample in order to keep it easy to read.
Page 99
® Software R&S TS-PIO3B Sample Programs /* read port 0 */ status = rspio3b_ReadPort (vi, RSPIO3B_DIG_PORT_0, & portVal); /* set all bits of port 0 to active high */ status = rspio3b_SetPort (vi, RSPIO3B_DIG_PORT_0, 0xFF, 0xFF); /* read port 0 */ status = rspio3b_ReadPort (vi, RSPIO3B_DIG_PORT_0, &...
Automatic detection Fuse test : only in combination with R&S TS-PIO3B 10.1 LED test After the system is switched on, all the LEDs of the module will briefly light up. This indicates that the required power supply has been applied and all LEDs are in proper order.
Page 101
AUX lines by the user, changes the expected A/D converter voltage. In this case the limits against which the value shall be compared, can be manually specified by the user in the file physical. ini within the relevant section for the module R&S TS-PIO3B. Example: SFTFuseTest = 1.2,0.8...
In the event of any discrepancies between date in this user manual and technical data in the data sheet, the data sheet takes precedence. The technical data of the Digital I/O Module R&S TS-PIO3B are shown in the corre- sponding data sheets.
Need help?
Do you have a question about the TS-PIO3B and is the answer not in the manual?