Tecal 140H
Calibrators
Operator's Manual
Issue 6
Date of issue:
3rd May 2005
Techne is a trademark
© Techne, 2003

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Tecal 140H and is the answer not in the manual?

Questions and answers

Summary of Contents for Techne Tecal 140H

  • Page 1 Tecal 140H Calibrators Operator's Manual Issue 6 Date of issue: 3rd May 2005 Techne is a trademark © Techne, 2003...
  • Page 3: Table Of Contents

    T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L CONTENTS Hi-Spec Dri-Block Calibrator Operator’s Manual ® page SAFETY AND INSTALLATION English Français Deutsch Español THE CALIBRATOR Applications Warning...
  • Page 4 T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L PAGE 2...
  • Page 5 T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L NOTES PAGE 3...
  • Page 6: English

    The unit is guaranteed against any defect in material or workmanship for the period specified on the enclosed Techne have taken great care in the design of these units guarantee card. This period is from the date of purchase, to protect operators from hazards, but users should pay...
  • Page 7: Français

    6. Les symboles situés sur ou à côté de l’interrupteur de l’appareil ont la signification suivante : Techne a apporté un soin tout particulier à la conception de : arrêt ces appareils de façon à assurer une protection maximale : marche des opérateurs, mais il est recommandé...
  • Page 8: Deutsch

    Geräteteilen durchzuführen. Sicherheit des Anwenders Diese Gebrauchsanleitung wurde ausschließlich dazu Alle Benutzer von Techne Geräten müssen Zugang zu der erstellt, um Kunden die Handhabung der Techne-Geräte entsprechenden Literatur haben, um ihre Sicherheit zu zu erleichtern. Nichts in dieser Gebrauchsanleitung darf gewähren.
  • Page 9: Español

    : Indicador de sobretemperatura materiales combustibles. Techne ha puesto gran cuidado en el diseño de estos 6. Los símbolos que se encuentran en o cerca del aparatos para proteger al usuario de cualquier peligro; aún interruptor de alimentación tienen los siguientes...
  • Page 10: The Calibrator

    A NAMAS certificate can be provided, contact your dealer for details. Temperature cycling You can connect a PC to the Tecal unit using Techne's Data Logging software, CALSOFT, to gather data. You may also print out profiles using the printer connected to the PC.
  • Page 11: Warning

    HIGH TEMPERATURES ARE DANGEROUS: they can cause serious burns to operators and ignite combustible material. Techne have taken great care in the design of these units to protect operators from hazards, but operators should pay attention to the following points: •...
  • Page 12: Specification

    T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L Specification The figures stated in the specification are as measured 0-50 mm from the base of the well of the insert, using an SPRT, at the time of calibration. Measuring zone 0 to 50 mm 0"...
  • Page 13: The Front Panel

    T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L THE FRONT PANEL The control panel of the Tecal units consists of a membrane keypad, an alphanumeric LCD panel, an LED display and three LEDs.
  • Page 14: Front Panel Controls

    T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L The Front Panel Controls The ESC key " ENTER ABCD EFGH IJKL ON/OFF PAUSE MNOP QRSTU VWXYZ (0-9)
  • Page 15 T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L The ON/OFF key " ENTER ABCD EFGH IJKL ON/OFF PAUSE MNOP QRSTU VWXYZ (0-9) The ON/OFF key allows the operator to start or stop the unit in Manual Mode or stop a program in Program Mode.
  • Page 16 T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L Power Indicator The top indicator shows that there is power to the unit Power to the Block Indicator The next indicator shows when there is power to the block.
  • Page 17: When You Switch On

    T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L When you Switch On When you first switch on, the display will show a choice of options. MAIN MENU manual mode program mode...
  • Page 18: Manual Mode

    T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L MANUAL MODE To go into the Manual Mode, use the # # # # # key to put the cursor on manual mode then press the ENTER key.
  • Page 19: Program Mode

    T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L PROGRAM MODE To go into the Program Mode, use the # # # # # key to put the cursor on program mode then press the ENTER key.
  • Page 20: New Program

    T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L New Program If you have chosen New Program the following screen will appear NEW PROGRAM name: _ _ _ _ _ _ _ _ Use the keys with letters beneath them to enter the name of the program...
  • Page 21: Program Running Display

    T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L Program Running Display The Display will automatically go into the the program running display as described earlier.
  • Page 22: Switch Test

    T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L Switch Test The switch test indicates the switch point temperature of a thermostat by detecting the making or breaking of the circuit made by the contacts of the thermostat.
  • Page 23: Program Delete

    T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L Program Delete PROGRAM MODE run program new program delete program To go into the Program Delete Mode from the Program Mode screen, use the # # # # # key to put the cursor on delete program then press the ENTER key.
  • Page 24: Water Cooling

    The cooling fan in the calibrator will automatically switch off if there is a chilled water supply. A Techne CH-5 chiller may be used to supply chilled water but in an ambient above 20°C it may not achieve the lowest temperatures. Switch on the chiller unit before the calibrator and allow the chiller to stabilise for 15 minutes before performing a calibration.
  • Page 25: Rs232 Serial Interface

    T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L RS232 SERIAL INTERFACE The calibrator may send data logging information to an IBM PC or compatible computer by connecting the unit and the PC via an RS232 cable, and installing the "Calsoft"...
  • Page 26: Technical Information

    Please include any details of the fault observed and remember to return the unit in its original packing. The insert must be removed from the unit and packed separately within the case. Techne accept no responsibility for damage to units which are not properly packed for shipping: if in doubt, contact your supplier.
  • Page 27: Replacement Parts

    T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L Replacement parts Each unit is supplied with an extraction tool, a carrying case and a mains cable.
  • Page 28: Inserts

    T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L Inserts Inserts are made from aluminium or aluminium-bronze and must be ordered separately from the calibrator. Each insert is stamped for identification. A blank insert is available which may be drilled to suit your application.
  • Page 29: Glossary

    T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L GLOSSARY Block temp. The current temperature of the heat transfer block. Cursor The flashing bar on the LCD screen which indicates where the next character is entered.
  • Page 30 T E C A L 1 4 0 H O P E R A T O R ’ S M A N U A L PAGE 28...