Breathable Air

NEVER use air from this compressor for breathable air except in full compliance with OSHA
1.
Standards 29 CFR 1910 and any other Federal, State or Local codes or regulations.
DANGER
2.
DO NOT use air line anti-icer systems in air lines supplying respirators or other equipment used to
produce breathable air. DO NOT discharge air from these systems in unventilated or other confined
areas.

Pressurized Components

This equipment is supplied with a ASME designed pressure vessel protected by an ASME rated relief valve. Pull the
ring before each use to make sure the valve is functional. Refer to figure 10. DO NOT attempt to open valve while the
machine is under pressure.

Personal Protective Equipment

Be sure all operators and others around the compressor and its controls comply with all applicable OSHA, Federal,
State and Local regulations, codes and standards relating to personal protective equipment. This includes respiratory
protective equipment, protection for the extremities, protective clothing, protective shields and barriers, electrical
protective equipment, and personal hearing protective equipment.
WARNING
CAUTION
A forklift may be necessary for unloading the Polar Air compressor. Use all forklift safety measures and require a
certified forklift operator. Refer to figure 1 for safe unloading procedure.
Death or serious injury can result from inhaling compressed air
without using proper safety equipment. See OSHA standards on safety
equipments.

Inspection

Inspect compressor prior to any use. Check for external damage that
might have occurred during transit. Be careful of moving parts then test
pulley by turning it freely by hand. Report any damage to delivery carrier
immediately.
Make sure pallet-mounted compressors are firmly secured to the
pallet before moving. NEVER attempt to move a compressor that is not
secure as serious injury or property damage could occur.