KitchenAid KGCC506RWW Installation Instructions Manual

KitchenAid KGCC506RWW Installation Instructions Manual

30 76.2 cm and 36 91.4 cm gas built-in cooktop
Hide thumbs Also See for KGCC506RWW:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

DE LA TABLE DE CUISSON À GAZ ENCASTRÉE DE
COOKTOP SAFETY........................................................................2
INSTALLATION REQUIREMENTS ................................................3
Tools and Parts ............................................................................3
Location Requirements................................................................3
Electrical Requirements ...............................................................5
Gas Supply Requirements ...........................................................5
INSTALLATION INSTRUCTIONS ..................................................7
Prepare Cooktop for Installation..................................................7
Install Cooktop .............................................................................7
Make Gas Connection .................................................................8
Attach Cooktop to Countertop ....................................................9
Complete Installation .................................................................10
WIRING DIAGRAMS.....................................................................11
IMPORTANT:
Installer: Leave installation instructions with the homeowner.
Homeowner: Keep installation instructions for future reference.
IMPORTANT :
Installateur : Remettre les instructions d'installation au propriétaire.
Propriétaire : Conserver les instructions d'installation pour référence ultérieure.
W10526074A
INSTALLATION INSTRUCTIONS
30" (76.2 CM) AND 36" (91.4 CM)
GAS BUILT-IN COOKTOP
INSTRUCTIONS D'INSTALLATION
30" (76,2 CM) ET 36" (91,4 CM)
Table of Contents/Table des matières
SÉCURITÉ DE LA TABLE DE CUISSON ....................................13
EXIGENCES D'INSTALLATION ...................................................14
Outillage et pièces......................................................................14
Exigences d'emplacement.........................................................14
Spécifications électriques ..........................................................16
Spécifications de l'alimentation en gaz .....................................16
INSTRUCTIONS D'INSTALLATION.............................................18
Installation de la table de cuisson..............................................18
Raccordement au gaz ................................................................20
Achever l'installation ..................................................................22
SCHÉMAS DE CÂBLAGE ............................................................23

Advertisement

Table of Contents
loading

Summary of Contents for KitchenAid KGCC506RWW

  • Page 1: Table Of Contents

    INSTALLATION INSTRUCTIONS 30" (76.2 CM) AND 36" (91.4 CM) GAS BUILT-IN COOKTOP INSTRUCTIONS D'INSTALLATION DE LA TABLE DE CUISSON À GAZ ENCASTRÉE DE 30" (76,2 CM) ET 36" (91,4 CM) Table of Contents/Table des matières COOKTOP SAFETY................2 SÉCURITÉ DE LA TABLE DE CUISSON ........13 INSTALLATION REQUIREMENTS ..........3 EXIGENCES D'INSTALLATION ...........14 Tools and Parts ................3...
  • Page 2: Cooktop Safety

    COOKTOP SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER”...
  • Page 3: Installation Requirements

    In the State of Massachusetts, the following installation instructions apply: Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the State of Massachusetts. If using a ball valve, it shall be a T-handle type. A flexible gas connector, when used, must not exceed 3 feet.
  • Page 4 Product Dimensions Cabinet Dimensions Metal Cooktops IMPORTANT: If installing a range hood or microwave hood combination above the cooktop, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface. A. 31⁷⁄₁₆" (79.8 cm) on 30" (76.2 cm) models, 37⁹⁄₁₆"...
  • Page 5: Electrical Requirements

    Electrical Requirements Gas Supply Requirements WARNING WARNING Electrical Shock Hazard Explosion Hazard Plug into a grounded 3 prong outlet. Use a new CSA International approved gas supply line. Do not remove ground prong. Install a shut-off valve. Do not use an adapter. Securely tighten all gas connections.
  • Page 6 Gas Supply Line Gas Pressure Regulator Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the The gas pressure regulator supplied with this cooktop must be cooktop location. A smaller size pipe on longer runs may used. The inlet pressure to the regulator should be as follows for result in insufficient gas supply.
  • Page 7: Installation Instructions

    INSTALLATION INSTRUCTIONS Style 2: Cooktop over cabinets Prepare Cooktop for Installation 1. Determine whether your cabinet construction provides clearance for installing clamping brackets at cooktop base ends. This is the recommended location. Clamping brackets WARNING can be installed on the front and back of cooktop base bottom, if necessary.
  • Page 8: Make Gas Connection

    6. Tighten screws just enough to hold brackets in place when cooktop is put in cutout. Make Gas Connection 7. Using 2 or more people, turn the cooktop right side up and place in cutout. WARNING NOTE: Make sure that the front edge of the cooktop is parallel to the front edge of the countertop.
  • Page 9: Attach Cooktop To Countertop

    Typical flexible connection WARNING 1. Apply pipe-joint compound made for use with LP gas to the smaller thread ends of the flexible connector adapters (see G in the following illustration). 2. Attach 1 adapter and nipple to the gas pressure regulator and the other adapter and nipple to the gas shutoff valve.
  • Page 10: Complete Installation

    Complete Installation Check Flame Height Electronic Ignition System Adjust the height of surface burner flames. The surface burner “low” flame should be a steady blue flame Initial lighting and gas flame adjustments approximately ¼" (0.64 cm) high. Surface burners use electronic igniters in place of standing pilots. When the cooktop control knob is turned to the “LITE”...
  • Page 11: Wiring Diagrams

    WIRING DIAGRAMS On 30" (76.2 cm) models Plug 120 VAC 60 Hz 1 Phase 15 or 20 AMP Neutral Line ⁵⁄₁₆" Wide Blade ¼" Wide Blade Ground Round Blade G or G/Y Connect .250 Terminals Spark Module Y or BR Valve (4) PLCS Switches...
  • Page 12 Notes...
  • Page 13: Sécurité De La Table De Cuisson

    SÉCURITÉ DE LA TABLE DE CUISSON Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité.
  • Page 14: Exigences D'installation

    Dans l’État du Massachusetts, les instructions d’installation suivantes sont applicables : Les travaux d’installation et réparation doivent être exécutés par un plombier ou tuyauteur qualifié ou licencié, ou par le personnel qualifié d’une entreprise licenciée par l’État du Massachusetts. Si une vanne à boisseau sphérique est utilisée, elle doit comporter une manette “T”. Si un conduit de raccordement flexible est utilisé, sa longueur ne doit pas dépasser 3 pi.
  • Page 15 Dimensions du produit Tables de cuisson métalliques ⁷⁄₁₆ A. 31 " (79,8 cm) sur les modèles de 30" (76,2 cm), ⁹⁄₁₆ " (95,4 cm) sur les modèles de 36" (91,4 cm) ¹⁄₄ B. 21 " (53,4 cm) ⁷⁄₈ C. 2 "...
  • Page 16: Spécifications Électriques

    Spécifications électriques Spécifications de l'alimentation en gaz AVERTISSEMENT AVERTISSEMENT Risque d'explosion Risque de choc électrique Utiliser une canalisation neuve d'arrivée de gaz Brancher sur une prise à 3 alvéoles reliée à la terre. approuvée par la CSA International. Ne pas enlever la broche de liaison à la terre. Installer un robinet d'arrêt.
  • Page 17 Canalisation de gaz Régulateur de pression de gaz Installer une canalisation de gaz rigide de ¾" (1,9 cm) jusqu'à Le régulateur de pression de gaz fourni avec cette table de cuisson l'emplacement d'installation de la table de cuisson. L'emploi doit être utilisé. La pression d'alimentation du régulateur de pression d'une canalisation de plus petit diamètre ou plus longue peut doit être comme suit pour un fonctionnement correct causer une déficience du débit d'alimentation.
  • Page 18: Instructions D'installation

    INSTRUCTIONS D'INSTALLATION Préparation de la table de cuisson pour Installation de la table de cuisson l'installation Style 1 : Table de cuisson sur four encastré sous comptoir IMPORTANT : Ne pas utiliser de brides de fixation. AVERTISSEMENT 1. À l'aide de 2 personnes ou plus, placer la table de cuisson dans l'ouverture, côté...
  • Page 19 Installation des brides avant de positionner la table de Installation des brides après avoir positionné la table de cuisson dans l'ouverture cuisson dans l'ouverture 1. À l'aide de 2 personnes ou plus, placer la table de cuisson à 1. À l'aide de 2 personnes ou plus, placer la table de cuisson l'envers sur une surface couverte.
  • Page 20: Raccordement Au Gaz

    Raccordement au gaz Utiliser uniquement un composé d'étanchéité des tuyauteries AVERTISSEMENT conçu pour l'utilisation avec le gaz naturel ou le propane. Ne pas utiliser de ruban TEFLON ® . Il sera nécessaire de choisir les raccords à utiliser en fonction de la configuration d'installation.
  • Page 21: Fixation De La Table De Cuisson Au Plan De Travail

    3. Ôter les chapeaux de brûleur de surface et les grilles du sachet de pièces. Aligner les encoches des chapeaux de Fixation de la table de cuisson au plan de brûleur avec les broches dans la base de chaque brûleur. Un travail chapeau de brûleur correctement placé...
  • Page 22: Achever L'installation

    Achever l'installation Vérification de la taille des flammes Système d'allumage électronique Pour le réglage au débit thermique minimum, on doit observer des flammes stables bleues d’environ ¼" (0,64 cm) de hauteur. Allumage initial et réglages des flammes À la place de flammes de veille, les brûleurs de surface sont dotés d'un allumeur électronique.
  • Page 23: Schémas De Câblage

    SCHÉMAS DE CÂBLAGE Sur les modèles de 30" (76,2 cm) Fiche 120 VCA 60 Hz 1 Phase 15 ou 20 A Broche neutre Broche ⁵⁄₁₆" de large d'alimentation de ¹⁄₄" de large Broche ronde de mise à la terre VE ou VE/JA Terre Terminaux de connexion 0,250...
  • Page 24 W10526074A © 2012 Whirlpool Corporation. 7/12 All rights reserved. Printed in U.S.A. Tous droits réservés. Imprimé aux É.-U.

This manual is also suitable for:

Kgcc506rbl

Table of Contents