If the pump will not start again automatically when cooling down, please check the following
conditions:
Is there a sufficient water supply?
Has the screen become clogged?
Has dirt entered the pump housing?
Have hoses or jets become clogged?
Has the pump sufficiently cooled down after overheating?
As soon as you have completed this checklist, you can start the pump again by
plugging it back in.
Maintenance and cleaning (see fig2)
1.
Follow these safety instructions. Make sure that the pump is unplugged.
2.
Loosen the 3 screws (1) and remove the lower screen (2).
3.
Loosen the 4 screws (3), and remove the pump house (4) and hoop (9).
4.
Turn the pump house cover (7) in Anti-clockwise direction; remove the pump house
cover (7) from the pump body (8).
5.
Take the impeller assembly (5) out from the pump body (8).
6.
Clean all parts using water and soft sponge.
7.
For hard water deposits or rust, use a solution of CLR (or like product)
with water (1:4 ratio is recommended).
Assembling the pump together:
1
Place the impeller assembly (5) pump body (8) with caution.
2. Make sure the impeller assembly (5) is assembled correctly and will turn freely and check
the position of the sealing ring (6) on the pump body (8).
3.
Turn the pump house cover (7) in a clockwise direction. Put the pump house cover (7)
in the pump body (8)
4.
Move the hoop (9) in the correct position and assemble the pump house (4). Tighten
the 4 screws (3) uniformly.
5.
Assemble the lower screen (2) and tighten the 3 screws (1) uniformly.