Half Off Ponds Pond Pulse PP3000 Operation Manual page 3

Submersible water pump

Advertisement

Model
PP3000
PP4200
PP5500
PP6500
CAUTION: These Pumps should be installed according to your local electrical installation
code. Please contact an electrician.
For all technical data, please refer to the content stated on the rating label of the pump.
These pumps are not for use in swimming pools!
Safety instructions
Read and observe all the instructions supplied with the appliance and on the appliance.
Make sure that the outlet voltage corresponds to the stated on the rating label of the
pumps.
Make sure the appliance is securely installed before operating it.
The electrical connection should be located in a water-proof area and should be at
least 6 feet away from the edge of the pond (see fig.1).
Keep the electrical connections dry! Ensure that the electrical cord loops below the
electrical outlet to form a "Drip Loop" (see fig. 3). This will prevent water from running
down the cord into the electrical outlet.
Always unplug the appliance when not in use, before putting on or taking off parts,
before cleaning the pumps and before doing any work for the fountain or pond.
The pump must not be used when people are working in water. Please disconnect the
pump first.
Do not operate any appliance with a damaged cord or plug, or in abnormal state. The
supply cord of the appliance cannot be replaced. If the cord is damaged the
appliance should be scrapped.
For safety reasons, any repair work should be done only by the manufacturer of the
products or the authorized service facility or discard it.
Never hang or transport the pump by means of pulling the power cord!
Close supervision is necessary when the appliance is used by or near children.
If you want to disconnect the pump, you can pull out the plug and the plug must be
placed where you can access it.
Never use accessories which are not recommended by the appliance manufacturer. It
may result in fire, electric shock and/or personal injury.
The pump is to be connected through a Ground Fault Circuit Interrupter (GFCI with a
rated residual operating current not exceeding 30mA.
Min. Length of power cord: 33 feet. Do not use extension cords.
V-Hz
120V 60Hz
120V 60Hz
120V 60Hz
120V 60Hz
Amps
Head (FT)
2.55A
20
3.8A
28
4.5A
32
5.17A
32
Flow (GPH)
3000
4200
5500
6500

Advertisement

loading

This manual is also suitable for:

Pond pulse pp4200Pond pulse pp5500Pond pulse pp6500