Press and release the
key or do not carry out
any other operations for 15 seconds: the
compressor LED
will switch off;
•
Press and release the
key.
To exit the procedure before its completion:
•
Do not carry out any operations for 15 seconds
(any changes will be saved).
8.1.3.5 Temperature setting in the
Automatic mode (SP2)
•
Make sure that the keyboard is not locked
(paragraph 8.1.3.3) and that no other advanced
procedure is in progress;
•
key: "SP1" will be
Press and release the
shown on the display;
•
Press either the
or the
shown on the display;
•
Press and release the
key: the compressor
LED will flash;
•
Press either the
or the
seconds; parameters r1, r2 and r5 can also be
seen;
•
Press and release the
key or do not carry out
any other operations for 15 seconds: the
compressor LED (
) will switch off;
•
Press and release the
key.
To exit the procedure before its completion:
•
Do not carry out any operations for 15 seconds
(any changes will be saved).
8.1.3.6 Timeslot settings for the switching
on/off of the equipment
N.B.
Before proceeding with the timeslot settings,
set day and real time as described in
paragraph 8.1.3.14.
To start the procedure:
•
Make sure that the keyboard is not blocked and
that no other advanced procedure is in progress;
•
key: "SP1" will be
Press and release the
shown on the display.
To set the first timeslot:
•
Press and release either the
within 15 seconds to select "HOn1" (first switching
on time) and/or "HOf1" (first switching off time);
select "HOn2" and "HOF2" for the second
switching on/off time;
•
Press and release the
key;
Page 26
•
Press and release either the
and within 15 seconds;
•
Press and release the
any other operations for 15 seconds.
To associate a time slot to a certain day of the week:
•
After the previous procedure has been carried out,
press either the
go within 15 seconds in order to select "Hd1"
(switch on time for day 1, or rather Monday) and/or
"Hd2...7" (switching on time for days 2-7, or rather
Tuesday-Sunday);
•
Press and release the
•
Press and release either the
within 15 seconds in order to select "1" (the first
switch on/off time) or "2" (the second switch on/off
time);
•
Press and release the
any other operations for 15 seconds.
key until "SP2" is
To exit the procedure before its completion:
•
Do not carry out any operations for 15 seconds
(any changes will be saved) or press the
key within 15
and then let it go.
8.1.3.7 Display of the operating status
•
Make sure that the keyboard is not locked
(paragraph 8.1.3.3) and that no other advanced
procedure is in progress;
•
Press and release the
Auto/ECO/Obst/Anti will be displayed for 3
seconds depending on the current active operative
status.
8.1.3.8 Silencing of the alarm sound
To silence the alarm, carry out the following procedure:
•
Make sure that no other advanced procedure is in
progress;
•
Press any key once.
or the
key
or the
key or do not carry out
or the
key and then let it
key;
or the
key or do not carry out
Carefully evaluate enabling of time slot operation
in order to avoid malfunctions caused by users.
key:
N.B.
The following instructions are reserved for
specialised technical assistance personnel.
Installation and user manual
key
key
key