General Safety

General Safety
- Always place the dispenser in its vertical position,
on a surface which can capably support its weight.
- During use this machine must remain in
its upright position.
- Adequate ventilation must be allowed for - we
recommend using the supplied ventilation ducting kit.
- Keep the machine away from sunlight, heat and moisture.
- The environment where this machine is installed must be
free of dust and corrosive/explosive gases.
Basic Troubleshooting
Problem/Report
No Water Dispensing
No Sparkling Water -
If applicable
Poor Quality Carbonation -
If applicable
Warm Drinks
Possible Cause
Water Pressure Regulator
No CO2 pressure
Carbonator Tank Not Filling
Air in Carbonator Tank
Residue in Carbonator Tank
Carbonator Tank is Overfilled
Insufficient cooling air flow through the fridge
Compressor not running
PCB not operating
Fridge failure
Suggested Action
Contact your distributor
Check CO2 bottle, regulator and non- return
valve. Supply pressure should be 58 psi (3.5-
4bar), replace as necessary
Contact your distributor
Isolate the power supply and operate the
sparkling water tap until gas is expelled. Allow
gas to expel for 5 seconds. Switch on power
supply and allow the tank to refill
After prolonged use, a surface film can develop
within the carbonator tank. Refer to cleaning
and sanitising instructions
If pump runs continuously, contact your
distributor
Check that the ventilation kit has been installed
correctly.
Contact your distributor