Advertisement

Quick Links

INSTALLATION, USE AND CARE MANUAL
FOR PROFESSIONAL VENTILLATION FOR
1. THIS APPLIANCE WAS DESIGNED FOR EASE OF INSTALLATION AND OPERATION. HOWEVER, WE
RECOMMEND THAT YOU READ ALL SECTIONS OF THIS MANUAL BEFORE YOU BEGIN INSTALLA-
TION.
2. DO NOT REMOVE PERMANANTLY AFFIXED LABELS, WARNINGS OR DATA PLATES FROM YOUR
APPLIANCE. THIS MAY VOID THE MANUFACTURER'S WARRANTY AND/OR HINDER EFFECTIVE
SERVICING AND MAINTENANCE.
3. THESE INSTRUCTIONS ARE TO REMAIN WITH THE APPLIANCE AND THE CONSUMER IS TO RE-
TAIN THEM FOR FUTURE REFERENCE.
4. PLEASE OBSERVE ALL LOCAL AND NATIONAL BUILDING CODES AND ORDINANCES. IF NO LO-
CAL CODES ARE APPLICABLE, PLEASE FOLLOW ALL WIRING REQUIREMENTS IN ACCORDANCE
WITH THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 EDITION.
5. PLEASE CHECK WITH A QUALIFIED AND TRAINED INSTALLER OR YOUR LOCAL CODES FOR ANY
MAKE UP AIR REQUIREMENTS.
6. THIS HOOD IS FOR RESIDENTIAL USE ONLY AND IS NOT DESIGNED FOR INSTALLATION OVER A
COMMERCIAL PRODUCT.
7. MAKE SURE ALL POWER IS TURNED OFF AT THE MAIN BREAKER OR FUSE BOX BEFORE MAKING
ANY CONNECTIONS.
8. TO AVOID RISK OF FIRE , ELECTRIC SHOCK, OR INJURY TO PERSONS, TURN OFF THE ELECTRIC-
ITY TO THE HOOD FROM THE POWER SUPPLY BEFORE CLEANING OR SERVICING.
This product is intended for domestic use only!
© Copyright 2012 Prizer –Painter Stoves Works
THE HOME
IMPORTANT!—PLEASE READ AND FOLLOW
"REV 1 – 6/14/2012"
P/N 750306 Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PL30240 and is the answer not in the manual?

Questions and answers

Summary of Contents for BlueStar PL30240

  • Page 1 INSTALLATION, USE AND CARE MANUAL FOR PROFESSIONAL VENTILLATION FOR THE HOME IMPORTANT!—PLEASE READ AND FOLLOW 1. THIS APPLIANCE WAS DESIGNED FOR EASE OF INSTALLATION AND OPERATION. HOWEVER, WE RECOMMEND THAT YOU READ ALL SECTIONS OF THIS MANUAL BEFORE YOU BEGIN INSTALLA- TION.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Table of Contents ........................... 2 Safety Instructions ..........................3-4 Introduction ............................5 Welcome ..............................6 Handling & Unpacking .......................... 7 Packing list for your Vent Hood ....................... 8-9 Pro Line Hoods ......................... 8 Pyramid Style Hoods ....................... 9 Low Profile and Re-Circulating hoods ..................
  • Page 3: Safety Instructions

    IMPORTANT!—PLEASE READ AND FOLLOW 1. THIS APPLIANCE WAS DESIGNED FOR EASE OF INSTALLATION AND OPERATION. HOWEVER, WE RECOMMEND THAT YOU READ ALL SECTIONS OF THIS MANUAL BEFORE YOU BEGIN INSTALLA- TION. 2. DO NOT REMOVE PERMANANTLY AFFIXED LABELS, WARNINGS OR DATA PLATES FROM YOUR APPLIANCE.
  • Page 4 WARNING! TO REDUCE THE RISK OF A RANGETOP GREASE FIRE (CONTINUED):  IF YOU ARE FLAMING LIQUOR OR OTHER SPIRITS, AND YOUR APPLIANCE IS INSTALLED UNDER A VENT HOOD, TURN THE FAN OFF. THE DRAFT CREATED COULD CAUSE THE FLAMES TO SPREAD OUT OF CONTROL.
  • Page 5: Introduction

    Since 1880, we have been dedicated to quality! We believe that our success can only be measured by the continuing success of our customers. We achieve customer satisfaction by ensuring that each of our employees understands, meets and exceeds customer expectations. We establish and maintain an environment that encourages all employees to pursue continuous improvement in qual- ity and productivity.
  • Page 6: Welcome

    You have purchased one of the finest appliances available for home use, which shows that you take cooking seriously. As the owner of a new BlueStar appliance you can look forward to years of cooking enjoyment. You will prepare meals with the speed and accuracy of a professional chef right in your own kitchen! All equipment is designed and manufactured to the highest quality standards in the in- dustry specifically to meet the needs of the world’s most demanding chefs: you.
  • Page 7: Handling & Unpacking

    MAKE SURE BLOWERS ARE FREE FROM OBSTRUCTIONS (PACKING AND DEBRIS). TEST RUN BLOWERS BEFORE FINALIZING INSTALLATION. CHECK WITH MANUFACTURER BE- FORE ATTEMPTING TO USE OTHER THAN BLUESTAR BLOWER SYSTEMS. FOR TECHNI- CAL INFORMATION CONTACT BLUESTAR SERVICE (800-449-8691) P/N 750306 Page 7...
  • Page 8: Packing List For Your Vent Hood

    PACKING LIST FOR PRO LINE HOOD SERIES PL30240——24” depth  No blower (Sold and Packaged Separately)  Two (2) Stainless Steel Baffle Filters  Two (2) Pre-Installed Lights  Lid for Electrical Box  Use and Care Manual with Wiring Diagram PL36240, PL42240—24”...
  • Page 9: Pyramid Style Hoods

    PACKING LIST FOR PYRAMID STYLE HOOD SERIES PC30240—24” depth  No blower (Sold and Packaged Separately)  Two (2) Stainless Steel Baffle Filters  Two (2) Pre-Installed Lights  Lid for Electrical Box  Use and Care Manual with Wiring Diagram ...
  • Page 10: Low Profile And Re-Circulating Hoods

    PACKING LIST FOR LOW PROFILE HOOD SERIES BS-LPL24240, BS-LPL30240——24” depth  One Pre-Installed 600 CFM blower  Two (2) Stainless Steel Baffle Filters  Two (2) Pre-Installed Lights  Lid for Electrical Box  Use and Care Manual with Wiring Diagram BS-LPL36240——24”...
  • Page 11: Dimensions

    DIMENSIONS OF THE PRO LINE SERIES HOOD 3-3/16”  INLET LOCATION FOR THE ELECTRICAL CONNECTION IS LOCATED NEAR THE REAR CENTER OF HOOD 3-3/16” FROM HOOD BOTTOM.  ELECTRICAL REQUIREMENTS: 15 AMPS AT 120 VOLTS  LIGHT BULBS ARE HALOGEN G9, 120V, 25W ...
  • Page 12: Site Preparation

    SITE PREPARATION FOR PRO LINE SERIES IN SELECTING THE PROPER HEIGHT TO MOUNT THE HOOD, TAKE INTO CONSIDERATION THE STATURE OF THE PERSON OR PERSONS WHO WILL BE COOKING. A HEIGHT OF 30", MINIMUM HEIGHT OFF OF COOKING SURFACE, TO 36" MAXIMUM HEIGHT OFF OF THE COOKING SURFACE, WILL SUIT MOST USERS.
  • Page 13: The Correct Height

    THE CORRECT HEIGHT OF YOUR PRO LINE SERIES HOOD HEIGHT ABOVE COUNTERTOP 30"(MIN)-36"(MAX) 76.2CM-91.4CM HEIGHT FROM FLOOR 68"(MIN)-72"(MAX) 167.6cm-182.9cm COUNTERTOP THE BOTTOM OF THE HOOD SHOULD BE 30" MINIMUM TO 36" MAXIMUM ABOVE THE COUNTERTOP. THIS WOULD TYPICALLY RESULT IN THE BOTTOM OF THE HOOD BEING 66" TO 72"...
  • Page 14: Duct Information

    SIZE TO 8” FOR OPTIMAL PERFORMANCE IMPORTANT PLANNING INFORMATION! PROPER INSTALLATION OF DUCTING IS EXTREMELY INPORTANT FOR OPTIMAL PERFORMANCE OF YOUR BLUESTAR VENTILLATION SYSTEM.  ALL CFM’S ARE BASED ON TESTS AT 0.1 STATIC PRESSURE; WITHOUT STATIC PRESSURE, ALL CFM’S WOULD BE OVERSTATED.
  • Page 15: Blower Installation

    INSTALLATION OF YOUR PRO LINE SERIES HOOD BLOWER INSTALLATION OF BS-PLIB600 INTERNAL BLOWER KIT REFER TO WIRING DIAGRAM 1. REMOVE SHIPPING BRACKET (SEE ITEM 1)FROM HOOD. DO NOT DISCARD SCREWS! 2. INSTALL BLOWER BRACKET WITH THE SCREWS REMOVED FROM THE SHIPPING BRACKET.
  • Page 16: Custom Duct Installation

    INSTALLATION GUIDE FOR PRO LINE DUCT COVER  REMOVE POP RIVETS FROM PRO HOOD THAT CORRESPOND WITH THE SMALL HOLES ON THE DUCT COVER.  INSTALL HOOD TO CORRECT HEIGHT (BE CAREFUL TO LEAVE 12” FOR DUCT COVER)  SLIDE DUCT COVER OVER TOP OF HOOD ...
  • Page 17: Dimensions

    DIMENSIONS OF THE PYRAMID STYLE SERIES HOOD P/N 750306 Page 17...
  • Page 18: Site Preparation

    SITE PREPARATION FOR PYRAMID STYLE SERIES IN SELECTING THE PROPER HEIGHT TO MOUNT THE HOOD, TAKE INTO CONSIDERATION THE STATURE OF THE PERSON OR PERSONS WHO WILL BE COOKING. A HEIGHT OF 30", MINIMUM HEIGHT OFF OF COOKING SURFACE, TO 36" MAXIMUM HEIGHT OFF OF THE COOKING SURFACE, WILL SUIT MOST USERS.
  • Page 19: The Correct Height

    THE CORRECT HEIGHT OF YOUR PYRAMID STYLE HOOD HEIGHT ABOVE COUNTERTOP 30"(MIN)-36"(MAX) 76.2CM-91.4CM HEIGHT FROM FLOOR 68"(MIN)-72"(MAX) 167.6cm-182.9cm COUNTERTOP THE BOTTOM OF THE HOOD SHOULD BE 30" MINIMUM TO 36" MAXIMUM ABOVE THE COUNTERTOP. THIS WOULD TYPICALLY RESULT IN THE BOTTOM OF THE HOOD BEING 66" TO 72"...
  • Page 20: Duct Information

    SIZE TO 8” FOR OPTIMAL PERFORMANCE IMPORTANT PLANNING INFORMATION PROPER INSTALLATION OF DUCTING IS EXTREMELY INPORTANT FOR OPTIMAL PERFORMANCE OF YOUR BLUESTAR VENTILLATION SYSTEM.  ALL CFM’S ARE BASED ON TESTS AT 0.1 STATIC PRESSURE; WITHOUT STATICE PRESSURE, ALL CFM’S WOULD BE OVERSATED.
  • Page 21: Blower Installation

    INSTALLATION OF YOUR PYRAMID STYLE HOOD BLOWER INSTALLATION OF BS-PCIB600 INTERNAL BLOWER KIT REFER TO WIRING DIAGRAM 1. REMOVE SHIPPING BRACKET(SEE ITEM 1) FROM HOOD. DO NOT DISCARD SCREWS! 2. INSTALL BLOWER BRACKET WITH THE SCREWS REMOVED FROM THE SHIPPING BRACKET.
  • Page 22: Flue Installation

    INSTALLATION GUIDE FOR FLUE (PYRAMID STYLE HOOD) 1. MEASURE FROM TOP OF THE CANOPY TO CEILING AND SUBTRACT 1/8" FOR CLEAR- ANCE. 2. PLACE THE DUCT COVER TOP INSIDE THE DUCT COVER BASE AND LOWER UNTIL DE- SIRED HEIGHT IS FOUND. (TO ELIMINATE SCRATCHES, MAKE A MARK ON THE DUCT COVER TOP FOR THE DESIRED LOWERING POINT BY SUBTRACTING 15"...
  • Page 23: Dimensions

    DIMENSIONS OF THE LOW PROFILE SERIES HOOD  INLET LOCATION FOR THE ELECTRICAL CONNECTION IS LOCATED ON TOP FOR STANDARD TOP EXHAUST AND ON REAR FOR OPTIONAL REAR EXHAUST. (SEE DETAIL BELOW)  ELECTRICAL REQUIREMENTS: 15 AMPS AT 120 VOLTS ...
  • Page 24: Site Preparation

    SITE PREPARATION FOR LOW PROFILE SERIES HOOD IN SELECTING THE PROPER HEIGHT TO MOUNT THE HOOD, TAKE INTO CONSIDERATION THE STATURE OF THE PERSON OR PERSONS WHO WILL BE COOKING. A HEIGHT OF 30", MINIMUM HEIGHT OFF OF COOKING SURFACE, TO 36" MAXIMUM HEIGHT OFF OF THE COOKING SURFACE, WILL SUIT MOST USERS.
  • Page 25: The Correct Height

    THE CORRECT HEIGHT OF YOUR LOW PROFILE SERIES HEIGHT ABOVE COUNTERTOP 30"(MIN)-36"(MAX) 76.2CM-91.4CM HEIGHT FROM FLOOR 68"(MIN)-72"(MAX) 167.6cm-182.9cm COUNTERTOP THE BOTTOM OF THE HOOD SHOULD BE 30" MINIMUM TO 36" MAXIMUM ABOVE THE COUNTERTOP. THIS WOULD TYPICALLY RESULT IN THE BOTTOM OF THE HOOD BEING 66" TO 72"...
  • Page 26: Duct Information And Wiring

    TRC8/6 TRANSITION IS AVAILABLE TO INCREASE THE DUCT SIZE TO 8” FOR OPTIMAL PERFORMANCE IMPORTANT PLANNING INFORMATION! PROPER INSTALLATION OF DUCTING IS EXTREMELY INPORTANT FOR OPTIMAL PERFORMANCE OF YOUR BLUESTAR VENTILLATION SYSTEM.  ALL CFM’S ARE BASED ON TESTS AT 0.1 STATIC PRESSURE; WITHOUT STATIC PRESSURE, ALL CFM’S WOULD BE OVERSTATED.
  • Page 27: Dimensions

    DIMENSIONS OF THE RE-CIRCULATING HOOD  INLET LOCATION FOR THE ELECTRICAL CONNECTION IS LOCATED ON TOP OR REAR. (SEE DETAIL BELOW)  ELECTRICAL REQUIREMENTS: 15 AMPS AT 120 VOLTS  LIGHT BULBS ARE HALOGEN G9, 120V, 25W  BULBS ARE OPERATED BY A DIMMER SWITCH ...
  • Page 28: Site Preparation

    SITE PREPARATION FOR RE-CIRCULATING HOOD IN SELECTING THE PROPER HEIGHT TO MOUNT THE HOOD, TAKE INTO CONSIDERATION THE STATURE OF THE PERSON OR PERSONS WHO WILL BE COOKING. A HEIGHT OF 30", MINIMUM HEIGHT OFF OF COOKING SURFACE, TO 36" MAXIMUM HEIGHT OFF OF THE COOKING SURFACE, WILL SUIT MOST USERS.
  • Page 29: The Correct Height And Wiring

    THE CORRECT HEIGHT OF YOUR RE-CIRCULATING HOOD HEIGHT ABOVE COUNTERTOP 30"(MIN)-36"(MAX) 76.2CM-91.4CM HEIGHT FROM FLOOR 68"(MIN)-72"(MAX) 167.6cm-182.9cm COUNTERTOP THE BOTTOM OF THE HOOD SHOULD BE 30" MINIMUM TO 36" MAXIMUM ABOVE THE COUNTERTOP. THIS WOULD TYPICALLY RESULT IN THE BOTTOM OF THE HOOD BEING 66" TO 72"...
  • Page 30: Cleaning And Maintenance

    CLEANING AND MAINTENANCE YOUR HOOD MUST BE KEPT CLEAN AND MAINTAINED PROPERLY!! BAFFLE FILTERS  BAFFLE FILTERS SHOULD BE EXAMINED PERIODICALLY TO ASSURE THAT ALL SUR- FACES AND PARTS ARE CLEAN  THE FILTERS ARE DISHWASHER SAFE OR IN A SINK WITH HOT, SOAPY WATER ...
  • Page 31: Warranty

    WARRANTY WHAT IS COVERED? Prizer-Painter provides the following limited warranties to the original retail purchasers of Products sold and installed in the continental United States and Canada on or after February 22, 2002: Initial Seven (7) Day Limited Warranty. Prizer-Painter warrants that all cosmetic components of its products will, under normal use and service, be free from defects in materials and workmanship for a pe- riod of seven (7) calendar days from the date of delivery (the "Warranty Period") to the original retail pur- chaser.
  • Page 32 WARRANTY WHAT IS NOT COVERED? This Limited Warranty is the sole and exclusive warranty provided for the Product and extends only to original retail purchasers in the continental United States and Canada. This Limited Warranty is not trans- ferable to any subsequent purchasers or users. If any implied warranties arise under any applicable law (including, but not limited to, implied warranties of merchantability and fitness for particular purpose), then the duration of those implied warranties will last only as long as the express warranties stated above.
  • Page 33: Performance Checklist

    PERFORMANCE CHECKLIST This checklist has been developed to assure proper installation of your appliance To validate your warranty you must mail or fax this form and a copy of your receipt to: Warranty Department, Prizer-Painter, 600 Arlington Street, Reading, PA 19611, Fax (610) 376-2596 Customer Information (Please Print) Product Information (Please Print) Name:________________________________________ Model No: ________________________________...
  • Page 34 PERFORMANCE CHECKLIST This checklist has been developed to assure proper installation of your appliance To validate your warranty you must mail or fax this form and a copy of your receipt to: Warranty Department, Prizer-Painter, 600 Arlington Street, Reading, PA 19611, Fax (610) 376-2596 Customer Information (Please Print) Product Information (Please Print) Name:________________________________________ Model No: ________________________________...

Table of Contents