Download Print this page
BlueStar PL Series Installation And Use & Care Manual

BlueStar PL Series Installation And Use & Care Manual

Wall hoods

Advertisement

Quick Links

INSTALLATION and
USE & CARE
WALL HOODS
PL, PY, IN, PM, HA, BZ, MH, WR, SC
197299
Version C

Advertisement

loading
Need help?

Need help?

Do you have a question about the PL Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BlueStar PL Series

  • Page 1 INSTALLATION and USE & CARE WALL HOODS PL, PY, IN, PM, HA, BZ, MH, WR, SC 197299 Version C...
  • Page 2 Please take a few moments now to fill in the information below for your future reference. In the event you require parts or service, this information will be needed to ensure you receive the highest quality service we can provide. DATE OF PURCHASE: DEALER’S NAME: DEALER’S ADDRESS:...
  • Page 3: Table Of Contents

    Table of Contents INSTALLATION INSTRUCTIONS: Handling and Unpacking Installation of Ducting & Electrical Specifications Removing Liner from Shell | Mounting Shell to Wall Installing In-Hood Blowers Installing Remote Blowers Installing In-Line Blowers Installing Wall Hood Duct Covers Installing Manhattan Series Ventilation Hoods USE AND CARE INSTRUCTIONS: Operating the Push Button Controls Cleaning Instructions...
  • Page 4: Installation Instructions

    INSTALLATION INSTRUCTIONS IMPORTANT 1. This appliance was designed for ease of installation and operation. However, we recommend that you read all sections of this manual before you begin installation. 2. Do not remove permanently affixed labels, warnings or data plates from your appliance. This may void the manufacturer’s warranty and/or hinder effective servicing and maintenance.
  • Page 5: Handling And Unpacking

    INSTALLATION INSTRUCTIONS To reduce the risk of cooking appliance grease fire: • Never leave the appliance unattended during use. Boil overs may occur causing spills which may ignite. • It is recommended you purchase a multi-purpose dry chemical or foam type fire extinguisher for your home and store it in close proximity to your appliances.
  • Page 6 INSTALLATION INSTRUCTIONS Unpacking: • Check the package for damage. If any damage is visible you should mark the bill of lading you sign that there may be concealed damage. • Ensure the container is upright. If the container is not upright major damage can occur to your appliance. If damage is discovered do not refuse delivery Contact the dealer and file appropriate freight claims.
  • Page 7 INSTALLATION INSTRUCTIONS Installation of Ducting for Proper Operation: IMPORTANT Proper installation of ducting is extremely important for optimal performance of your ventilation system. It is a basic requirement that the kitchen is provided with an air intake to ensure good air circulation and therefore proper operation of the hood.
  • Page 8 INSTALLATION INSTRUCTIONS Step 2: Remove ventilation hood liner from outer shell. (Figures A through F) Figure A: Figure B: Figure C: Figure D: Remove Baffle Filters Remove Grease Trough Remove Inner Shield Remove Control Panel Pull filters towards you to Turn fastening screw(s) ¼...
  • Page 9 INSTALLATION INSTRUCTIONS Step 4-1: Installing In-hood 600 CFM Blowers Figure A: Figure B: Figure C: Figure D: Attach Blower Connect Plate Internally Connect Plate Externally Connect Power Supply Unscrew blower plate and Re-install all mounting Re-install all mounting Connect molex connector set to top or rear discharge.
  • Page 10: Installing Remote Blowers

    INSTALLATION INSTRUCTIONS Step 4-3. Installing Remote Blowers MODEL NUMBER: HYEX-1.0/HY-EX-1.4 MAXIMUM CFM: 1000 CFM/1400 CFM VOLTS/HERTZ/AMPS: 115VAC, 60 Hz, 2.9A (HYEX-1.0) and 3.3A (HYEX-1.4) HYEX-1.0: 8” Round (51 sq. in. equiv.) / HYEX-1.4: 10” Round (80 sq. in. equiv.) REQUIRED DUCT SIZE: IMPORTANT: Remove foam block from FLAT OR LOW SLOPE ROOF inside housing before operating...
  • Page 11 INSTALLATION INSTRUCTIONS Step 4-3. Installing Remote Blowers ELECTRICAL CONNECTIONS Figure 3 WARNING: TURN OFF POWER AT THE SERVICE BOX PRIOR TO WIRING BLOWER 1. Power supply for the blower s 115V AC, 60 Hz. See page 2 for specifications 2. Run electrical cable between the blower and the range hood or blower and wall switch.
  • Page 12: Installing In-Line Blowers

    INSTALLATION INSTRUCTIONS Step 4-4. Installing In-line Blowers Mounting Option 1: Please follow all applicable codes when installing this unit 1. Equipment should be hung at its proper elevation by using temporary fixtures that can be removed after vibration hangers are installed. 2.
  • Page 13 INSTALLATION INSTRUCTIONS Step 4-4. Installing In-line Blowers Dimensions and Wiring: Model Weight ATEX-0.8 12 ½ 15 ½ 19 lbs ATEX-1.2 21 lbs Step 5. Mount Outer Shell to Wall 1. The bottom of the hood should be 30” minimum to 36” maximum above the countertop for efficient operation. 2.
  • Page 14 INSTALLATION INSTRUCTIONS: 1-PIECE DUCT COVERS Step 8-1. Installing 1-Piece Duct Cover Option 1 1. Secure duct cover to top of hood using machine screws provided. 2. Mount complete unit to wall using instructions in Step 4 for Mounting Outer Shell to Wall. 3.
  • Page 15 INSTALLATION INSTRUCTIONS: TELESCOPIC DUCT COVERS Step 8.3 Installing Telescopic Duct Cover Option 1 Mounting Bracket 1. Attach mounting bracket to wall 1/8” from ceiling and centered with hood. Upper Duct 2. Attach lower portion of duct cover to hood with hardware Optional provided.
  • Page 16 INSTALLATION INSTRUCTIONS Manhattan Style Wall Hoods 1. Follow Step 2 of installation instructions on removing liner from outer shell. 2. Mount duct to ceiling using method below that best applies to your application. 3. Mount blower(s) into duct cover using hardware provided. 4.
  • Page 17: Use And Care Instructions

    USE & CARE INSTRUCTIONS Section 1: Control Panel Blower Timer Light Controls Controls Blower Controls: Additional Controls: A – Blower starts on 1 E – Timer speed B – 2 speed Pressing button during operation will cause C – 3 speed blower to run for 5 minutes at its current speed.
  • Page 18 USE & CARE INSTRUCTIONS Section 3: Baffle Filters IMPORTANT The function of the baffle filters is the absorption of grease particles that form during cooking. Do not operate ventilation hood without filters in hood. Baffle filters should be examined periodically to assure that the surfaces and parts are clean.
  • Page 19 USE & CARE INSTRUCTIONS Make sure that the electrical power is off before cleaning. The recommended detergent is a solution of water and a neutral liquid soap. It is very important for the liquid soap to not contain granules that could scratch the surface.