Maintenance; Specifications - C.A.P. XGC-1e Specification Sheet

Xtreme greenhouse controller
Table of Contents

Advertisement

p
recauTions
1) Please take care in the handling of this precision device. If the unit is dropped or subjected to extreme shock, the calibration
may be thrown off. Calibration problems due to abuse, or droppage may affect the warranty.
2) DO NOT expose the XGC-1e to water. It utilizes a ventilated enclosure to properly "sample" the CO
s
:
pecificaTions
System operating voltage
Maximum Switching amperage
Overload protection
Operating temperature
Maximum humidity
Temperature control range
Humidity control range
Adjustable timer repeatability
Timer setting accuracy
Hydro "ON" timer
Hydro "OFF" timer
24-hour timeclock accuracy
CO
Operating principle
2
CO
Measurement range
2
CO
Warm-up time
2
CO
Maximum drift per year
2
CO
Accuracy @ 77'F
2
CO
Repeatability
2
CO
Calibration interval
2
CO
sensor Operating life expectancy
2
Dimensions
Weight
Relay operations
m
:
ainTenance
1) Consult the troubleshooting chart for a listing of the most common problems.
2) DO NOT open the enclosure!!! There are no components that require maintenance.
3) Do not use this equipment for purposes other than what it is designed for. It will provide many years of trouble-free service when
used properly.
4) In the event you cannot solve the problem, first consult the dealer who sold the unit then contact the factory for instructions on
how to return it to the factory for repair.
Liability statement:
R & M Supply and their retailers and distributors are not responsible for any damage or injuries (consequential or otherwise) arising
from the use of this device. The purchaser assumes all responsibility for the use and proper installation of this device.
m
aintenance
120vac +/- 20% @ 50-60 Hertz
15-amps @ 120vac
15-amp normal blow fuse
30-120º F
95% RH (Non-condensing)
50-115º F with a 7º F differential, +/- 3.6º
20 - 80% RH with a 5% differential
+/- .5% under fixed conditions
+/- 10%
30 seconds to 20 minutes
12 minutes to 480 minutes
+/- 3% monthly
Fuzzy Logic™, w / Single-beam Non-Dispersive Infrared (NDIR)
0 – 5000 PPM CO
Minimum 10 minutes (full accuracy)
+/- 15 PPM
+/- 5% of reading
< 1% of Fixed Scale
Three years
15 years typical
10" X 8" X 7"
Less than 6 lbs.
Minimum 100,000 electrical / 10,000,000 mechanical