Before attempting to operate the XGC, you should at least take the time to
look at the Example Connection diagram on page 2 and read the "Start-
up Procedure on page 3 of this manual. To get the most out of the XGC-
1e, familiarize yourself with this manual. It contains many useful hints,
examples and a troubleshooting guide.
i
s
T
mporTanT
Tuff
o
The XGC is designed to operate from a 120vac, 15-amp power source. It can
safely control up to 15-amps of equipment including up to 1000 watts of HID
lights. If required, additional lights and larger equipment can be connected
to the XGC-1e by using our HPR, MLCs or UPM "Universal Power Modules".
In addition to lights, the XGC also maintains the temperature and humidity by
controlling your exhaust fan(s). CO
in timers, which are coordinated with your exhaust fans and function only
when the lights are ON.
p
& s
roTecTion
afeTy
The XGC is overload protected a main 15-amp fuse. Do not exceed the
maximum rating of the XGC-1e.
IMPORTANT: Replace blown fuses with fuses of the same rating ONLY!
Note: A surge suppressor / power strip is always recommended when
operating electrical equipment such as the XGC.
W
arranTy
The XGC is protected by our 3-year limited warranty. All components are
warranted by R & M Supply against defects in workmanship and materials under normal use for 3-years from the date of purchase. The XGC
is 100% maintenance-free and does not require service.
i
/ s
nsTallaTion
TarT
There are a few requirements for a successful installation and start-up.
1) The XGC must be mounted in a vertical position. Mounting feet are included to allow you to secure the unit to a wall.
2) The XGC requires "free air movement" to maintain temperature and humidity accuracy. The top and bottom of the enclosure has
ventilation slots to provide airflow through the unit however, we greatly recommended using an oscillating fan in the growing area to
provide fresh air for the internal humidity sensor and provide adequate ventilation for the internal electrical components.
3) A dedicated 120 VAC, 15-amp power supply is recommended. A ground wire (3-wire outlet) must be used. Do not use 2-wire adapters or
cords to operate the XGC.
4) The XGC must be protected from water. Do not mount the unit where it can be exposed directly to water.
5) Read the rest of the manual!!! It has been designed to take you through step-by-step to make start-up a breeze.
XGC-1e Xtreme Greenhouse Controller
The XGC-1e Xtreme greenhouse controller from C.A.P. controls all of the
main devices that are used in today's modern hydroponic garden. The built-in
Fuzzy Logic
controls your CO
r
emember
levels can be controlled with the built-
2
-u
p
level with unmatched accuracy.
2

Advertisement

Table of Contents
loading

Summary of Contents for C.A.P. XGC-1e

  • Page 1 15-amps of equipment including up to 1000 watts of HID lights. If required, additional lights and larger equipment can be connected to the XGC-1e by using our HPR, MLCs or UPM “Universal Power Modules”. In addition to lights, the XGC also maintains the temperature and humidity by controlling your exhaust fan(s).
  • Page 2 “The XGC-1e is a self-contained greenhouse control system designed for people who want simply the best all-in-one controller available”. Humidity Controller 2 Exhaust Outlets 24 hour timeclock Hydro “ON” timer Night device outlet device outlet “fronT panel” Temperature Controller...
  • Page 3: Start-Up Procedure

    vervieW “There is no substitute for reading and understanding the operating manual however... You can use the instructions on this page for a trouble -free start-up”. TarT 1) Locate a suitable source for power. A 3-wire, grounded, 15-amp dedicated circuit is recommended. 2) Secure the enclosure to a wall using the enclosed mounting “feet”.
  • Page 4: Temperature Controller

    What set’s the XGC-1e apart from the competition? Fuzzy logic… What is “fuzzy logic”? Fuzzy Logic can be compared to a good driver. As a good driver approaches a red light, he or she applies the brakes to gradually slow down BEFORE getting to the intersection. Fuzzy...
  • Page 5 The XGC-1e uses 2 timers to control the hydroponic pump functions. It also has a 24-hour time-clock which controls your daytime and nightime functions. djusTable ecyclinG imers The two Adjustable Recycling Timers (ART) provide an adjustable “ON” / “OFF” cycle for various devices. The 2-adjustable recycling timers onboard the XGC are set using the dials on the front face of the enclosure.
  • Page 6 +/- 15-25 PPM. If after a few days of operating the XGC-1e you are not satisfied with the performance, you can try to allow the unit to “re-teach” itself the base parameters FOR YOUR SPECIFIC AREA. And that is exactly what the “Auto-Tuning” function does. When the “Auto-Tuning” function...
  • Page 7: C Hanging C Ontrol M Odes

    14) Reconnect the Exhaust fans, CO continue to stand next to the XGC-1e while monitoring. Just keep an eye on the display and record the level every 30 minutes or so. Also try to observe the unit reacting to and recovering from the Exhaust fans operating. The level should drop down to 800 or less and then recover quickly without overshooting the setpoint more than 150 PPM.
  • Page 8 The XGC-1e is factory calibrated. The sensor onboard the XGC-1e is capable of remaining in calibration for a minimum of three years. Extreme shock during shipping and other factors may affect the calibration. To check the calibration, follow the procedure below.
  • Page 9 The XGC-1e can be upgraded and expanded by using our expansion devices including the UPM-1, and the MLC-4. The Universal Power Modules and Master Lighting Controllers allow you to run multiple pumps, fans and lights by controlling remote relays.
  • Page 10: Troubleshooting

    We highly recommend using only 3-wire devices with a ground. Suitably double-insulated devices are acceptable. Keep in mind that the combined amperage draw on all of the devices connected to the XGC-1e must be less than 15-amps @ 120 VAC.
  • Page 11: Maintenance

    1) Please take care in the handling of this precision device. If the unit is dropped or subjected to extreme shock, the calibration may be thrown off. Calibration problems due to abuse, or droppage may affect the warranty. 2) DO NOT expose the XGC-1e to water. It utilizes a ventilated enclosure to properly “sample” the CO pecificaTions...