8 channel video receive unit with up to 2 bi-directional data and audio channels for a singlemode fibre link

Advertisement

Quick Links

8 Channel Video Receive Unit with up to 2 Bi-directional
Data and Audio Channels for a Singlemode Fibre Link
The AMG4784BxR-SF is a rackmount eight channel video receive unit designed to receive 8 video
signals and transmit and receive up to 2 data or audio signals over one Singlemode fibre.
The AMG4784BxR-SF is designed to plug into an AMG2009 or AMG2015 subrack, which in turn fits
into a 19" rack system.
The AMG4784BxR-SF is designed to operate with AMG4783Bx-SF or rackmount equivalent
AMG4783BxR-SF eight channel video transmit unit in a point to point configuration.
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
AMG4784BxR-SF
Instruction Manual
Page 1 of 12
AMG4784BxR-SF Instruction Sheet
D18351-00.doc

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMG4784BxR-SF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AMG AMG4784BxR-SF

  • Page 1 The AMG4784BxR-SF is a rackmount eight channel video receive unit designed to receive 8 video signals and transmit and receive up to 2 data or audio signals over one Singlemode fibre. The AMG4784BxR-SF is designed to plug into an AMG2009 or AMG2015 subrack, which in turn fits into a 19" rack system.
  • Page 2: Table Of Contents

    Removal / replacement from / to the Case..................9 Safety Maintenance and Repair AMG Systems Ltd. reserves the right to make changes to this Page 2 of 12 AMG4784BxR-SF Instruction Sheet document without notice. The information herein is believed to D18351-00.doc...
  • Page 3: Introduction

    It also transmits 2 data signal to the AMG4783Bx-SF. Optical Connection The AMG4784BxR-SF is connected as illustrated below when used with an AMG4783Bx-SF 8- channel transmit unit acting as a point to point system. AMG Systems Ltd. reserves the right to make changes to this...
  • Page 4: Connections

    Data Connector........RJ45 Channel B Interface ......Defined by data/audio interface daughter board fitted into Slot 1 on main board and indicated by the 'x' in the AMG partno. AMG Systems Ltd. reserves the right to make changes to this Page 4 of 12 AMG4784BxR-SF Instruction Sheet document without notice.
  • Page 5: Data And Audio Channel Configuration

    RS485 bus high (+5 volts) and the other arm low (0 volts) using high value resistors within the third party equipment. In order to ensure that the AMG equipment detects a tri-state condition, then these resistors should have a value above 5kΩ. If the third party bias resistors are less the 750Ω...
  • Page 6: Data / Audio Channel B Configuration

    Brown Note: (A) or (B) in brackets in above table refers to RS485 / RS422 data specification, not Channel A, Channel B. AMG Systems Ltd. reserves the right to make changes to this Page 6 of 12 AMG4784BxR-SF Instruction Sheet document without notice.
  • Page 7: Front Panel Indicators

    OUT+ logic one (-V) present on OUT+ This represents the data signals being received on the optical fibre AMG Systems Ltd. reserves the right to make changes to this Page 7 of 12 AMG4784BxR-SF Instruction Sheet document without notice.
  • Page 8 > 0dBm (overload at +6dBm) audio not present or < -40dBm This represents the audio signals being received from the optical fibre. AMG Systems Ltd. reserves the right to make changes to this Page 8 of 12 AMG4784BxR-SF Instruction Sheet document without notice.
  • Page 9: Physical Information

    There are no user serviceable parts within AMG products. See unit data sheet for full specification. In case of problem or failure, please call your local support centre or contact: AMG Systems Ltd. at 3 The Omega Centre, Stratton Business Park, Biggleswade, Beds., SG18 8QB, UK.
  • Page 10 This page is intentionally blank. AMG Systems Ltd. reserves the right to make changes to this Page 10 of 12 AMG4784BxR-SF Instruction Sheet document without notice. The information herein is believed to D18351-00.doc be accurate. No responsibility is assumed by AMG for its use.
  • Page 11 This page is intentionally blank. AMG Systems Ltd. reserves the right to make changes to this Page 11 of 12 AMG4784BxR-SF Instruction Sheet document without notice. The information herein is believed to D18351-00.doc be accurate. No responsibility is assumed by AMG for its use.
  • Page 12 This page is intentionally blank. AMG Systems Ltd. reserves the right to make changes to this Page 12 of 12 AMG4784BxR-SF Instruction Sheet document without notice. The information herein is believed to D18351-00.doc be accurate. No responsibility is assumed by AMG for its use.

This manual is also suitable for:

Amg4784bx-sf

Table of Contents