Chengdu Ebyte Electronic Technology Co,;Ltd
5
AUX
6
VCC
7
GND
8
ANT
9
Fixed orifice
10
Fixed orifice
11
Fixed orifice
4 Connect to MCU
No.
1
The UART module is TTL level.
2
For some MCU works at 5VDC, it may need to add 4-10K pull-up resistor for the TXD & AUX pin.
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co,;Ltd
be configured as open-drain or push-pull output
To indicate module ' s working status & wakes up the external MCU.
Output
During the procedure of self-check initialization, the pin outputs low
level. Can be configured as push-pull output (suspending is allowed).
Power supply :2.3~ 5.5V DC
Input
Ground
Input
Antenna interface (high frequency signal output)
Input
Fixed orifice
Fixed orifice
Fixed orifice
Description(STM8L MCU)
E30-433T20S user manual