Fig. 28: Carrying Out Wet Cleaning Of Compressor; Table 13: Parameters For Wet Cleaning Of Compressor - ABB HT604877 Operation Manual

Table of Contents

Advertisement

Operation Manual / A150-M56/66/57/67 - A155-M..
7 Periodic maintenance work / 7.2 Cleaning the compressor during op-
eration
Pressurized air from the compressor casing (72000) of the turbocharger passes through the
pipe (02) to the water pressure vessel (27000). As soon as the valve activator (03) is activ-
ated, water is pressed into the pipe (01) and routed to the filter silencer or air suction
branch.
The water does not act as a solvent. The coating is removed by the mechanical action of the
impacting droplets.
7.2.5
Carrying out wet cleaning of the compressor
Fig. 28: Carrying out wet cleaning of compressor
Engine load Filling amount of water pressure
50 ... 85 %
Table 13: Parameters for wet cleaning of compressor
Remove sealing plug (27005).
u
Fill container with 0.4 dm
u
Screw in sealing plug (27005) again.
u
Push the valve activator (03) against the spring and hold for 10 ... 15 seconds until the en-
u
tire volume of water is injected.
Continue to operate the engine for at least five minutes to ensure that all of the water is
u
flushed out of the system.
Not more than three cleaning cycles should be conducted consecutively. Before repeating
the process, continue to operate the engine for at least five minutes to ensure that all of the
water is flushed out of the system.
© Copyright 2021 ABB. All rights reserved.
72000
Compressor casing
27000
External water pressure vessel
27005
Sealing plug
01
Water pipe to filter silencer or air suction branch
02
Pressurized air inlet pipe
03
Valve activator
3
vessel [dm
]
0.4
3
of pure water.
HZTL4032_EN
Water temperature
[°C]
5 ... 30
Rev.Q
Water injection
period [s]
10
January 2021

Advertisement

Table of Contents
loading

This manual is also suitable for:

A155-m seriesA155-m67/1A150-m series

Table of Contents