AEG REGINA 1850 User Information page 45

Update environmentally friendly washing machine
Table of Contents

Advertisement

Problem
The display goes out
while a wash pro-
gramme is running.
Detergent residues are
accumulating in the
detergent drawer.
The rinse water is
cloudy.
The background illumi-
nation of the display
has gone out even
though the appliance is
switched on.
Water is not entering
the appliance. ATTEN-
TION CD 1 / PLEASE
OPEN THE TAP is show-
ing in the display.
The washing machine
drain pump runs con-
tinuously - even when
the appliance is
switched off.
Possible cause
A power failure has occurred.
For reasons related to safety,
the filling door will remain
locked for approx. 4 minutes.
The tap is not fully open.
The filter in the threaded in-
let hose fitting is clogged at
the tap or at the washing
machine.
The probable cause is a de-
tergent with a high silicate
content.
The washing machine is in
stand-by mode.
The tap is closed.
The filter in the threaded in-
let hose fitting is clogged.
The tap is furred with limes-
cale or faulty.
The Aqua Control anti-flood
system is in operation.
Remedy
As soon as the power failure
is over the wash programme
will continue.
If you wish to remove the
washing: If water is visible in
the viewing window, first
carry out an emergency
emptying procedure (see sec-
tion "Carrying out an emer-
gency emptying procedure").
After approx. 4 minutes the
door can be opened.
Turn the tap on fully.
Close the tap. Unscrew the
inlet hose from the tap and
from the machine. Clean the
filter.
No negative impact on the
rinse result; try using a liquid
detergent.
Press any of the buttons.
Open the tap.
Close the tap. Unscrew the
hose from the tap, take out
the filter and wash it under
running water.
Check the tap and have it re-
paired if necessary.
Close the tap, remove the
mains plug from the socket
and contact Service Force.