7A
7D
7B
7C
HOT
7 WATER SUPPLY CONNECTIONS
Gently separate hot and cold Supply Tubes (7A), approximately three inches apart.
Connect water Supply Lines (7C) to Faucet Inlets (7B). Hot water supply line goes to hot
inlet fitting indicated by red tag (7D). (Supply lines not included). Follow manufacturer's
instructions when installing supply lines.
Hold the Faucet Inlets (7B) steady using an adjustable wrench while tightening Supply
Lines (7C). Do not twist Supply Tubes (7A)!
DRAIN BODY INSTALLATION
8
8A
8 DRAIN INSTALLATION
Install and adjust Drain (8A) using separate instructions supplied with the Drain
assembly.
ENGLISH
7A
7B
7C
COLD
3
9
9 UNIT START UP
Turn on hot and cold water supplies, and check for leaks above and below the sink.
FAUCET FUNCTIONS
10
HOT
10A
COLD
10 FAUCET FUNCTION
By lifting the Lever Handle (10A) up, the valve will be activated allowing water to flow.
The water flow will increase by continuing to lift up the Lever Handle (10A). By rotating
the Lever Handle counter-clockwise, the water temperature will decrease to cold flow
only. By rotating the Lever Handle clockwise, the water temperature will increased to
hot flow only.
MAINTENANCE & CARE
11
11E
11D
11C
11 FLUSHING & AERATOR CLEANING
After installation is complete, remove Aerator Housing (11A). Turn Valves (11B) on
and allow both hot and cold water to run for at least one minute each. While water is
running, check for leaks. To clean the aerator, disassemble Aerator Housing (11A) by
separating the Aerator Shell (11C), Basket (11D), and Washer (11E). Once parts have
been cleaned, reassemble by reversing steps.