Download Print this page

Sealey AK49 Instruction Manual page 2

Adjustable flow grease gun

Advertisement

3. OPERATION
WARNING! An empty grease cartridge or grease is under pressure from the spring in the barrel, use caution when removing it.
r
3.1.
GREASE GUN LOADING
● Unscrew barrel anticlockwise.
● Pull back plunger rod fully and lock out with the tab (except when Suction Loading).
3.1.1.
Cartridge Loading
● Remove plastic cap from end of grease gun cartridge, insert into barrel of grease gun.
● Remove seal from grease gun cartridge and screw grease gun head back onto the barrel and undo the bleed valve (Fig.2).
● Release the plunger rod using its tab, force the rod out and in a few times to eject air trapped in the grease, from the bleed valve. When
grease comes out of the valve the air has been discharged.
● Fully tighten the bleed valve.
● Pump the grease gun handle until grease flows continuously. If it does not, loosen the bleed valve again and use the plunger rod to expel
the trapped air. Retighten the bleed valve once all air is discharged.
● Connect grease gun extension pipe and coupler onto grease gun outlet using PTFE tape, do not over tighten.
3.1.2.
Suction Loading
● Put open end of grease barrel into grease container to a depth of 50mm.
● Slowly pull back the plunger rod to pull the grease into the barrel. Lock the rod with the tab.
● Shake the grease gun to settle the grease into the barrel.
● Screw grease gun head back onto the barrel, open the bleed valve (Fig.2).
● Release the plunger rod using its tab, force it out and in a few times to eject air trapped in the grease, from the bleed valve. When grease
comes out of the bleed valve the air has been discharged.
● Fully tighten the bleed valve.
● Pump the grease gun handle until grease flows continuously. If it does not open the bleed valve and use the plunger rod to expel the
trapped air. Retighten bleed valve once all air is removed.
● Connect grease gun extension pipe and coupler onto grease gun outlet using PTFE tape, DO NOT over tighten.
3.2
USING GREASE GUN
3.2.1.
Select either low pressure/high volume or high pressure/low volume by sliding the catch down and moving the handle to engage the 'H or 'L'
position on the handle. (See Fig.3 & 4).
3.2.2.
The coupler has jaws which snap onto a grease nipple. Push the coupler straight onto the nipple to form a good fit.
3.2.3.
Operate the grease gun as square onto the nipple as possible.
3.2.4.
Once finished tilt the coupler twist and pull it off.
WARNING! DO NOT try to pull the coupler off straight.
r
Parts support is available for this product. To obtain a parts listing and/or diagram,
please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
© Jack Sealey Limited
Fig.3
Environmental Protection.
Recycle unwanted materials instead of disposing of them as
waste. All tools, accessories and packaging should be sorted,
taken to a recycle centre and disposed of in a manner which
is compatible with the environment.
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
www.sealey.co.uk
01284 757500
Web
sales@sealey.co.uk
01284 703534
email
AK49 Issue No.1 - 25/09/13
Fig.4

Advertisement

loading