ELECTRICAL INSTALLATION – IPI
WALL SWITCH INSTALLATION
The wall switch wire connection is located off the wire
harness coming out of the IPI Control Board. The wire is
labeled 'wall switch'. Connect the low voltage switch wires
to the two (2) terminals labeled "wall switch" from the control
IPI SYSTEM WIRING DIAGRAM
BLACK
RED
Figure 21. IPI System Wiring Diagram
Electrical connections should only be performed by a qualified, licensed electrician. Main
power supply must be turned off before connecting fans to the main electrical power supply
or performing service.
20
ORANGE
YELLOW
BLACK
BROWN
Monessen • VFF 32/36 Owner Manual • 20308184 • Rev F • 02/19
VFF Vent Free Fireplace System
board. Run wire to desired location on wall. Up to 50 feet
of 18 gauge wire may be used if necessary. Attach wires
to wall switch. Mount the wall switch in a junction box and
screw on cover. Figure 21
RED
RED
RED
BLACK
BLACK
RED