pyromaster UVHB26 Installation And Homeowners Operating Instructions

pyromaster UVHB26 Installation And Homeowners Operating Instructions

Vermont castings installation and homeowners operating instructions vent-free gas room heater uvhb26

Advertisement

",:,)
,,)
MA
@
Vent-Free
Gas ROOID Deaters
UVUB26
~I~~~I~
..., ."
...,.,.
I
,." ,. ,.
,.
I
,
,'.
..,..,.,. '
..,...'
.11".n
~
..." #"
..", ,...
..", ,...,
..." ,.,,~
.~: ~:I
.--.
"" "".
"" "".
'.""".
,
",
'.",..,.
'.".",..
'.""""
,.""""
., ",..
...",..
,"" "h,
'"""h.
"""'h.
"'I"'"
"'I"...
I~:~,
~I~~~I~
FP728
Installation and Homeowners
Operating Instructions
INSTAllER:
DO NOT DISCARD THIS MANUAL
Leave
in fireplace for homeowner.
PLEASE READ THIS MANUAL
BEFORE INSTALLING
AND USING APPLIANCE.
IMPORTANT: Read all instruc-
tions and warnings carefully
before starting installation.
Failure to follow these instruc-
tions may result in a possible
fire hazard and will void the
warranty.
WARNING: If the
information
in
this manual is not followed
exactly, a fire or explosion may
result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Installation and service must be
performed by a qualified in-
staller, service agency, or the
gas supplier. Do not store or
use gasoline or other flammable
vapors and liquids in the vicinity
of this or any other appliance.
FOR YOUR SAFETY
If you smell gas:
1. Open windows
2. Do not touch electrical
switches.
3. Do not try to light any appli-
ance.
4. Extinguish any open flame.
5. Do not use the phone in your
building.
6. Immediately call your gas
supplier from a neighbor's
phone.
7. Follow your gas supplier's
instructions.
8. If you cannot reach your gas
supplier, call the fire depart-
ment.
This is an unvented gas-fired
heater. It uses air (oxygen) from
the room in which it is installed.
Provisions for adequate com-
bustion and ventilation
air
must
be provided.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UVHB26 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for pyromaster UVHB26

  • Page 1 PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE. IMPORTANT: Read all instruc- tions and warnings carefully before starting installation. Failure to follow these instruc- tions may result in a possible fire hazard and will void the warranty. information WARNING: If the this manual is not followed exactly, a fire or explosion may result causing property damage,...
  • Page 2: Table Of Contents

    . ..> TABLB OF CONTENTS General Information....3 Specifications..... . 4 Heater Installation.
  • Page 3: General Information

    A professional service person should be contacted to inspect this heater annually. PYROMASTER@ UVHB26 Make it a practice to have all of your gas heaters checked annually. More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc.
  • Page 4: Specifications

    UVHB26 PYROMASTER@ UVHB26 Series Gas Appliance MANTEL FPS1212 FP21214 Fig. 1. UVHB26 Series specifications. UVHB26 Series Gas Appliance ~I§§§I~ ~I§§§ 26.5 47.374 UVHB26 Series specifications and dimensions. Vent-Free Heaters BRASS TRIM (TOP) BRASS TRIM (BOTTOM) HEARTH BASE 3/4" 39.625 MOUNTING TABS...
  • Page 5: Gas Supply Pressures

    The UVHB vent-free heaters is designed to be installed into a FPS1212 or FPS1214 mantel cabinet only. It may not be installed in any other manner. The UVHB26 is available in Natural or Propane gas, equipped with an oxygen depletion sensor with a standing pilot. MINIMUM...
  • Page 6: Heater Installation

    0 1. PREPARING THE UVHB26 To be sure that each step of the heater installation is in order, use the check-off boxes provided. The UVHB26 may only be used with the approved mantel and hearth assembly. 1. After determining a location, open the mantel hearth base carton and place into position on a solid surface.
  • Page 7 1/8" test point up stream of the control. « 1/2" GAS SUPPLY c::to 1/2" NPTx 1/2" FLARE SHUT-OFF VALVE 3/8" FLEX LINE Fig. 4. Typical gas supply intallation.. PYROMASTER@ UVHB26 Vent-Free Heaters install the FP297 A...
  • Page 8: Fan Operation

    The FK24 fan has a heat sensor that will not allow the fan to come on until heater reaches a preset temperature, approximately 100-120°F. Once the heater reaches temperature use the speed control knob to turn fan on and off to adjust fan speed. 5. FINAL ASSEMBLY 1. Final...
  • Page 9 11. 4. To turn the gas valve on, put the wall switch to the 'ON' position. PYROMASTER@ UVHB26 Vent-Free Heaters D 7. BOTTOM LOUVRE (GRILLE) REMOVAL To remove the bottom louvre (grille), lift louvre up and then out. See Figure 8.
  • Page 10: Log Installation

    PYROMASTER@ UVHB26 Vent-Free Heaters 10. lOG INSTAllATION (refer to fig. 9) 1. Set the back log on the studs attached to the burner pan. 2. Install the front log in-between the ember guard and front lip of the unit. This should be a snug fit.
  • Page 11: Operating Instructions

    Never use tools. If the knob will not push in or turn by hand, don't try to PYROMASTER@ UVHB26 Vent-Free Heaters repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
  • Page 12: To Turn Off Gas To Appliance

    PYROl'1ASTER@UVHB26 Vent-Free Heaters 6. Turn knob on gas control counterclockwise to PilOT. 7. Push in control knob all the way and immedi- ately light pilot depressing the piezo igniter button at least once every second until a flame appears. Continue to hold the control knob in for about one (1) minute after the pilot is lit.
  • Page 13: Maintenance

    Typically, the top 1/8" of the thermopile should be engulfed in the pilot flame. See Figure 12. PYROMASTER@ UVHB26 Vent-Free Heaters Fig. 12. Proper pilot flame height. FP499A...
  • Page 14: Flame Adjustment

    PYROMASTER@ UVHB26 Vent-Free Heaters The air shutter is set at factory no adjustment should be necessary. FLAME ADJUSTMENT For units equipped with Hilla valves, flame adjust- ment is accomplished by rotating the Hilla adjust- ment knob located near the center of the gas control.
  • Page 15: Troubleshooting - Honeywell Vs8421

    START PILOT LIGHTS WITH PIElO IGNITOR PILOT STAYS LIT PilOT LIGHTSMAIN I-NO-. BURNER I SYSTEM lK: PYROMASTER@ UVHB26 Vent-free Heaters Uoneywell VS8421 CHECK SUPPLY LINE HOOKED UP SHUTOFF VALVE OPEN LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN. .FORSPARKATELECTRODE WHILE DEPRESSING PIElO 1/8"...
  • Page 16: Accessories

    The following accessories for these heaters are available from your local Pyromaster distributor. Each accessory comes with a separate installation instruction for mounting to the particular heater. Be sure to read each instruction thoroughly before installing. ACCESSORIES - UVHB26 Accessory Variable speed, heat-activated, kit...
  • Page 17: Replacement Parts

    .,.". , '" ,...".. "",'" ". """.. ".".'. """.. """.." ... f'" "!':~~: ~I~~ 6a1b ."", " .,,/ PYROMASTER@ UVHB26 Vent-Free Heaters =. =-.~ /", <~ii/f:> "~// <:~~,. 1>/~'\.16 " '-.---- -if'> «::c> :> ~-=o-"--~ ~.-=?~ 2a1b 3a/b s::?------...
  • Page 18 PYROMASTER@ UVHB26 Vent-Free Heaters REPLACEMENT PARTS - UVC SERIES Description Log - Assembly 1a. Log - Back 1b. Log - Front 1c. Log - Left 1d. Log - Right 1e. Log - "Y" 2a. Valve - NAT Honeywell 2b. Valve - LP Honeywell 3a.
  • Page 19 CFM Corporation 2695 Meadowvale Boulevard Mississauga, Ontario L5N 8A3 Canada (800) 668-5323 www.cfmcorp.com...
  • Page 20 (4). These warranties are limited to repair, replacement or furnishing a replacement for sale, as specified in Paragraphs A and B, for a part found to CFM Harris Systems’ satisfaction, after examination, to be defective in materials or workmanship under normal conditions, use and service.

Table of Contents

Save PDF