Page 1
INSTALLATION, OPERATION & MAINTENANCE MANUAL Pizza Prep Tables Sandwich/Salad Units Under-counter Refrigerators and Freezers Worktop Refrigerators and Freezers IMPORTANT Please read this manual completely before attempting to install or operate this equipment.
UNDER-COUNTER REFRIGERATORS AND FREEZERS SAFETY INSTRUCTIONS General Safety Arctic Air accepts no responsibility for any situation resulting from work carried out in an WARNING unprofessional manner, or from the incorrect interpretation or application of regulations. General Installation Incorrect installation or any modifications made to the appliance may damage property or WARNING result in injury or death.
Installation, Operation & Maintenance Manual INTRODUCTION This.manual.covers.the.Under-counter.Refrigerators.and. Confirm that all flooring is structurally strong enough • Freezers..Please.read.this.manual.completely.before.at- to.support.the.weight.of.a.fully.loaded.unit;.a.fully. tempting.to.install.or.operate.this.equipment. loaded. unit. can. weigh. as. much. as. 1500. pounds.. . Consult with a structural engineer for confirmation if Site Preparation there is any reason to doubt the floor strength. Confirm that adequate ventilation has been provid- •...
UNDER-COUNTER REFRIGERATORS AND FREEZERS INSTALLATION Location Electrical connection All.units.are.intended.for.indoor.use.only..A.fully.loaded. Refer. to. the. amperage. data. provided. in. the. SPECIFI- unit.can.weigh.as.much.as.1500.pounds...Choose.a.loca- CATIONS,.the.serial.tag,.the.local.electrical.code.and/or. tion with a level floor strong enough to support the total the.National.Electrical.Code..Have.a.licensed.electrician. weight of a fully loaded unit. Reinforce the floor if neces- confirm that the facility wiring is adequate for the unit and sary..
Installation, Operation & Maintenance Manual MAINTENANCE Stainless Steel Care and Cleaning DANGER Stainless. steel. contains. 70-80%. iron. which. will. rust.. It. TURN OFF THE POWER SWITCH AND also. contains. 1-30%. chromium. which. forms. an. invis- DISCONNECT THE UNIT FROM THE POWER ible passive film over the steel’s.surface.that.acts.as.a.
One year parts & labor warranty Arctic Air warrants to the original purchaser, all of its new equipment to be free from defects in material or workmanship, under normal use and maintenance service, for a period of one (1) year from the date of original purchase or 15 months after shipment date from the manufacturer, whichever occurs first.
Page 21
Broich Enterprises, Inc. / Arctic Air 7550.Market Place Drive Eden.Prairie,.MN.55344 Phone:.95-941-70 Fax:.95-941-3066 Website:.www.arcticairco.com...
Need help?
Do you have a question about the APP-71R and is the answer not in the manual?