Parameter
DRAM Memory Mapping
NVDIMM
Memory MBIST
Description
Press [Enter] for more options
Chipselect Interleaving
Š
– Interleave memory blocks across the DRAM chip slects for node 0
– Options available: Disabled/Auto. Default option is Auto.
BankGroupSwap
Š
– Configures the BankGroupSwap. BankGroupSwap (BGS) is a
memory mapping option in AGESA that alters how applications get
assigned to physical locations within the memory modules. When
this option sets to Auto, it is null.
– Options available: Enabled/Disabled/Auto. Default option is Auto.
BankGroupSwapAlt
Š
– Configures the BankGroupSwapAlt.
– Options available: Enabled/Disabled/Auto. Default option is Auto.
Address Hash Bank
Š
– Enable or disable bank address hashing.
– Options available: Disabled/Enabled/Auto. Default option is Auto.
Address Hash CS
Š
– Enable or disable CS address hashing.
– Options available: Auto/Enabled/Disabled. Default option is Auto.
Address Hash Rm
Š
– Enable or disable RM address hashing.
– Options available: Auto/Enabled/Disabled. Default option is Auto.
SPD Read Optimization
Š
– Enable or disable SPD Read Optimization. Enabled = SPD reads
are skipped for Reserved fields and most of upper 256 Bytes,
Disabled = read all 512 SPD Bytes.
– Options available: Auto/Enabled/Disabled. Default option is Auto.
Press [Enter] for more options.
Press [Enter] for more options
MBIST Enable
Š
– Enable or disable Memory MBIST.
– Options available: Disabled/Enabled. Default option is Disabled.
Data Eye
Š
– Press [Enter] for more options.