Forced Operation; Auto Restart - LG S266SC Owner's Manual

Table of Contents

Advertisement

Operating Instructions

Forced Operation

Operation procedures when the remote
control can't be used.
The operation will be started if the power
button is pressed.
If you want to stop operation, re-press
the button.
Cooling Model
Operating mode
Indoor FAN Speed
Setting Temperature
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of
room temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, open the front panel upward and Press the power button let it be
pressed for about 3 seconds.
If you want to stop the operation, re-press the button.

Auto restart

In case the power comes on again after a power failure, Auto Restarting Operation is the function to
operate procedures automatically to the previous operating conditions.
So there is no need of activating this function by pressing any key or button.
In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later.
As the compressor starts, the fan speed also resumes its previous setting mode.
Helpful information
Fan speed and cooling capacity.
The cooling capacity indicated in the specification is the
value when the fan speed is set to high, and the capacity will
be lower at low or medium fan speed.
High fan speed is recommended when you wish to cool the
room quickly.
Room Temp. ≥ 24°C
Cooling
Cooling
High
High
22°C
22°C
ON/OFF
button
Heat pump Model
21°C ≤ Room Temp. < 24°C
Healthy Dehumidification
High
23°C
High
Speed
Room Temp. < 21°C
Heating
High
24°C
Owner's Manual 15

Advertisement

Table of Contents
loading

Table of Contents