Installation - HearthRite HB06ML-1 Owner's Operation And Installation Manual

Blue flame vent-free propane/lp gas space heater
Table of Contents

Advertisement

Figure 3 -Ventilation Air from Outdoors

INSTALLATION

NOTICE: This heater is
intended for use as supplemental
heat. Use this heater along with
your primary heating system. Do
not install this heater as your
primary heat source. If you have
a central heating system, you
may run system's circulating
blower while using heater. This
will help circulate the heat through-
out the house. In the event of a
power outage, you can use this
h e a t e r
a s
y o u r p r i m a r y
heat source.
WARNING:
A qualified
service
person
must install
heater. Follow all local codes.
CHECK GAS TYPE
Use only propane/LP gas. If your
gas supply is not propane/LP, do
not
install heater. Call dealer where
you bought heater for proper type
heater.
VENTILATION AIR
INSTALLATION NEEDS
Before installing heater, make sure
you have the items listed below.
piping (check local codes)
Propane/LP
sealant (resistant to
gas)
equipment shutoff valve*
ground joint union
test gauge connection*
sediment trap
tee joint
pipe wrench
*A CSA/AGA design-certified equip-
ment shutoff valve with 1/8
tap is an acceptable alternative to
test gauge connection. Purchase
the CSA/AGA design certified equip-
ment shutoff valve from your dealer.
LOCATING HEATER
This heater is designed to be
mounted on a wall.
For convenience and efficiency,
install heater
where there is an easy access for
operation, inspection, and service
in coldest part of room
CAUTION: If you install the
heater in a home garage
heater pilot and burner must
be at least 18 inches above
floor.
locate
heater where moving
vehicle will not hit it.
6
Ventilation Air From Outdoors
Provide extra fresh air by using
ventilation grills or ducts: You must
provide two permanent openings: one
"
within 12
of the ceiling and one within
"
12
of the floor.
Connect these items directly to the
outdoors or spaces open to the outdoors.
These spaces include attics and crawl
spaces. Follow the National Fuel Gas
Code NFPA 54/ANS Z223.1, Section 5.3.
Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
IMPORTANT: Do not provide openings
for inlet or outlet air into attic if attic has
a thermostat-controlled power vent.
Heated air entering the attic will activate
the power vent.
WARNING: Never install
the heater
in a bathroom (Models
H B 1 0 M L
a n d H B 1 0 T L o n l y
HB06ML is allowed in bathroom.
Check local codes.)
in a recreational vehicle.
where curtains, furniture,
clothing, or other flammable ob-
jects are less than 36 inches
from the front, top, or sides of the
heater.
as a fireplace insert.
in high traffic areas.
"
NPT
in windy or drafty areas.
When the HB06ML is installed in
bathrooms,do not use flammable
products such as aerosol hair spray,
foot spary or any product that contains
flammable vapors and keep towels
away from heater.(only HB06ML is al-
lowed in a bathroom.)
CAUTION: This heater
creates
warm
These
currents
t o w a l l
s u r f a c e s
h e a t e r . I n s t a l l i n g
next to vinyl or cloth wall
coverings or operating heater
where impurities (such as tobacco
smoke, aromatic candles, clean-
ing fluids, oil or kerosene lamps,
etc.) in the air exist may
discolor walls.
air
currents.
move
heat
n e x t
t o
h e a t e r

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hb10ml-1Hb10tl-1

Table of Contents