SELF PRIMING EXTERNAL PUMPS
Installation and Service Manual
for EXP3200, EXP5000, EXP6800, EXP7800, EXP6000HP
Please fill in for future reference:
MODEL: _____________________________
SERIAL NUMBER: ____________________
DATE PURCHASED: __________________
* Please fill out the warranty registration
card in this manual.
Model
INLET
DISCHARGE
MAX FLOW (gph)
MAX HEAD (feet)
MAX POWER (watts)
MAX CURRENT (amps)
VOLTS
MOTOR HP
MOTOR TYPE
MOTOR ENCLOSURE
WARNING: Please read completely before you install or operate your new pump! This is an external "out-of-pond" pump!
It is NOT submersible! Do NOT allow this pump to become submerged! Never run dry!
EasyPro
EXP3200
S/N: XXXX-XXXXXX
TYPE:
SELF PRIMING CENTRIFUGAL
MOTOR:
NEMA 56Y
HORSEPOWER:
1/2 (1750 RPM) 2 (3450 RPM)
MATERIAL:
GLASS-FILLED POLYPROPYLENE
HARDWARE:
STAINLESS STEEL HARDWARE
EXP3200
2"
2"
3200
15'
228
2.68 @ 115v
115/230
1/2
56Y
TEFC
Reliability You Can Count On!
*Actual appearance
may vary by model
OPTIONS:
ACCESSORIES:
EXP5000
EXP6800
2"
2"
2"
2"
5000
6800
18'
19'
310
369
3.37 @ 115v
3.93 @ 115v
115/230
115/230
1/2
1/2
56Y
56Y
TEFC
TEFC
SALTWATER SERVICE
SWING CHECK VALVES (1
/
", 2", 3")
1
2
EXP7800
2"
2"
7800
24'
504
5.02 @ 115v
115/230
1/2
56Y
TEFC
EXP6000HP
2"
2"
6000
60'
1416
8.7 @ 230v
115/230
2
56Y
ODP
© 2021 EasyPro, Inc.
Pg. 1

Advertisement

loading

Summary of Contents for EasyPro EXP3200

  • Page 1 SELF PRIMING EXTERNAL PUMPS Installation and Service Manual for EXP3200, EXP5000, EXP6800, EXP7800, EXP6000HP EasyPro EXP3200 S/N: XXXX-XXXXXX Please fill in for future reference: MODEL: _____________________________ SERIAL NUMBER: ____________________ DATE PURCHASED: __________________ * Please fill out the warranty registration card in this manual.
  • Page 2 4. Never restrict the intake. Keep both input and discharge lines as free of elbows and valves as possible. Always use pipe of adequate diameter. This will reduce friction losses and maximize output. 5. This pump must not be run dry! We recommend a flooded suction installation. Please read carefully! When properly installed, the EasyPro pump will provide dependable, trouble-free service.
  • Page 3 7. Remove ceramic piece from impeller (if replacing the seal). 8. Detach bracket from motor. Remove seal from bracket by pressing out from the back (if replacing the seal). Do not dig out from the front! Reliability You Can Count On! © 2021 EasyPro, Inc. Pg. 3...
  • Page 4 The exclusive remedies provided hereunder shall, upon EasyPro’s inspection and option, be either repair or replacement of EasyPro shall not be held liable for any loss of fish, plants or any other livestock as a result of any failure or defect of this the Product or parts covered under this warranty.

This manual is also suitable for:

Exp5000Exp6800Exp7800Exp6000hp