Troubleshooting Tips; Normal Operating Sounds - GE AGQ06 Owner's Manual And Installation Instructions

Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting Tips.

Problem
Air conditioner
does not start
Air conditioner does not
cool as it should
Air conditioner
freezing up
The remote control is
not working
Water drips outside
Water drips indoors
Water collects in
base pan
TIMER feature not
working properly

Normal Operating Sounds

s
You may hear a pinging noise caused by water being
picked up and thrown against the condenser on rainy
days or when the humidity is high. This design feature
helps remove moisture and improve efficiency.
14
Possible Causes
The air conditioner
is unplugged.
The fuse is blown/circuit
breaker is tripped.
Power failure.
Airflow is restricted.
The temp control may not
be set correctly.
The air filter is dirty.
The room may have been hot.
Cold air is escaping.
Cooling coils have iced up.
Ice blocks the air flow
and stops the air conditioner
from cooling the room.
The batteries are inserted
incorrectly.
The batteries may be dead.
Excessively hot and humid
weather.
The air conditioner is not
tilted to the outside.
Moisture is removed from
indoor air and drains into
rear of a cabinet where a fan
blows it against the outdoor
condenser coil.
A power outage or interruption
occurred.
What To Do
• Make sure the air conditioner plug is pushed completely
into the outlet.
• Check the house fuse/circuit breaker box and replace
the fuse or reset the breaker.
• If power failure occurs, turn the mode control to OFF.
When power is restored, wait 3 minutes to restart the
air conditioner to prevent tripping of the compressor
overload.
• Make sure there are no curtains, blinds or furniture
blocking the front of the air conditioner.
• On models with touch pads: In COOL mode, press the
DECREASE w pad.
• On models with control knobs, turn the temperature
knob to a higher number.
• Clean the filter at least every 30 days.
See the Operating Instructions section.
• When the air conditioner is first turned on you need to
allow time for the room to cool down.
• Check for open furnace floor registers and cold air returns.
• Set the air conditioner's vent to the closed position.
• See Air conditioner freezing up below.
• On models with control knobs, set the mode control at
HIGH FAN or HIGH COOL with the temp at 1 or 2.
• On models with touch pads, set the mode control at
HIGH (F3) FAN or HIGH (F3) COOL and set the thermostat
to a higher temperature.
• Check the position of the batteries. They should be
inserted in the opposite (+) and (–) direction.
• Replace the batteries.
• This is normal.
• For proper water disposal, make sure the air conditioner
slants slightly from the case front to the rear.
• This is normal for a short period in areas with little
humidity; normal for a longer period in very humid areas.
• In the case of a power outage or interruption, the unit
TIMER feature will reset to the original setting. You may
need to set a new time if desired.
s
You may hear the thermostat click when the compressor
cycles on and off.
s
Water will collect in the base pan during high humidity
or on rainy days. The water may overflow and drip from
the outdoor side of the unit.
s
The fan may run even when the compressor does not.