Download Print this page

Panasonic SW-100 Series Instruction Manual page 2

Optical touch switch

Advertisement

Terminal layout
● As the shape is different between A side terminal (termi-
nal No. 1 to 6) and B side terminal (terminal No. 7 to 12),
make sure to wire properly.
<A side terminal block>
Terminal No. Terminal name
Description
1
12 to 24V DC
+V
2
Output 1_1
Output 1
3
Output 1_2
4
Output 2_1
Output 2
5
Output 2_2
6
0V
0V
<B side terminal block>
Terminal No. Terminal name
Description
Switching terminal of time-
7
Timer (+V)
out function (+V)
Switching terminal of time-
8
Timer (IN)
out function (IN)
9
Output 3_1
Output 3
10
Output 3_2
11
IN2 (Orange) External input 2
12
IN1 (Green)
External input 1
Connecting to the terminal block
● When connecting to the terminal block, push the cable
with ferrule terminal into the back of the mounting hole.
If the cable is properly inserted, the lock is completed
and the cable does not fall if it is pulled.
● In case of using twisted wire directly, hold down the
release button and plug the cable into the back as
shown in the right figure. Conforming cable diameter
is shown below.
● In case of removing, hold down the release button and
pull the cable.
<Conforming cable>
Cable with no ferrule terminal (Twisted wire)
2
0.2 to 1.5mm
(AWG 24 to 16)
5
FUNCTIONS
1. Basic operation
● When a hand is touched to the sensing surface, thru-beam
type photoelectric sensor detects the hand, and output turns
ON or OFF.
2. Output
● Three semiconductor photo MOS relays are incorporated.
Output 1 : When an object is detected (beam is interrupted): OFF /
When an object is not detected (beam is received): ON
Output 2, 3 : When an object is detected (beam is interrupted)): ON /
When an object is not detected (beam is received): OFF
Note: When the power of the thru-beam type photoelectric sensor inside the main body turns
ON in beam interrupted condition, output 1 turns ON, while outputs 2 and 3 turn OFF,
then the fault indicator (yellow) lights up. In this case, once beam is received, the fault
indicator turns OFF and the sensor returns to normal operation.
3. Time-out function
● Unintended beam interrupted condition caused by dirt on the sensing surface,
etc. can be monitored.
• When beam interrupted condition (sensing condition) continues for 10 sec.
or more, output 1 turns ON, while output 2 and 3 turn OFF (output condition
is the same as non-sensing condition.)
• This function can be invalid by short-circuiting "between switching terminals
of time-out function (terminal No. 7 and No. 8)" as described below.
Note: W hen time-out function is operated, the fault indicator (yellow) lights up. In this case,
once beam is received, the fault indicator turns OFF and the sensor returns to normal
operation.
7 8
Short-circuit between the switching
terminals of time-out function
4. External input function
● External input indicators 1 and 2 of this product light up by the signal from
external input.
External input indicators 1 and 2:
Lights up when external input indicators 1 and 2 are valid (0 to 1V or 10V to +V).
Turns OFF when external input indicators 1 and 2 are invalid (4 to 6V or open).
Ramco National
A side terminal block
1 2 3 4 5 6
7 8 9 10 11 12
B side terminal block
<Bottom view>
Terminal No.1 has
no projection
Terminal No.12 has
no projection
Release
button
Cable with ferrule terminal
2
0.2 to 1.5mm
<Timing Chart (In case time-out function works)>
10 sec.
Non-
or more
Sensing
sensing
condition
Sensing
ON
Output 1
OFF
ON
Output 2
OFF
ON
Output 3
OFF
Lights up
Fault
indicator
Turns OFF
www.PanasonicSensors.com
6
TROUBLESHOOTING
● Fault indicator (yellow) blinks when an error occurs.
● An error can be identified by the number of blinks of the fault indicator.
Blinking
Error
Status of sensor
number
Output
1
Lockout
short-circuit
2
Dirt error
Normal operation Wipe out the sensing surface with a soft cloth.
Extraneous
4
Lockout
light error
5
Internal error
Lockout
Emission
6
Lockout
circuit error
Reception
7
Lockout
circuit error
● In case of lockout condition, when upper countermeasure is performed and
the power is supplied again, the operation returns to normal.
<Blinking cycle of the fault indicator [(e.g.) The number of blinks: 2 times]>
0.3s
0.3s
Lights up
Turns OFF
7
SPECIFICATIONS
Designation
Item
Model No.
CSA 22.2 No.14, CSA 22.2 No.0.8, ANSI/NFPA 79, UL 508,
Applicable standard
EN 60947-5-2 (EMC only)
Sensing method
Thru-beam type photoelectric sensor (2 beam axes)
Supply voltage
12 to 24V DC±10%, Ripple P-P10% or less
Current consumption
100mA or less (Excluding external connection load)
Semiconductor photo MOS relay output × 3
• Maximum load current: 100mA
Output
• Applied voltage: 30V DC or less (between output and +V)
• Residual voltage: 1.5V or less (at 100mA of load current)
Output 1
Output operation
Output 2, 3 : When an object is detected (light is blocked): ON /
Short-circuit protection
100ms or less when an object is detected
Response time
50ms or less when an object is not detected
Protection
IP65 (IEC) TYPE1 (UL 50) (Excluding terminal area)
-25 to +50°C (No dew condensation or icing allowed)
Ambient temperature
Storage: -30 to +70°C
Ambient humidity
Enclosure: Polycarbonate, Polyester resin
Material
Nut: PBT, Mouting packing: Silicone rubber
Connection cable
Up to 20m (cable diameter: 0.2 to under 0.3mm
length
Up to 100m (cable diameter: 0.3 or more to 1.5mm
Weight
8
CAUTIONS
● This product has been developed / produced for industrial use only.
● Confirm the wiring before power is supplied, as wrong wiring will damage the
internal circuit.
● Verify that the supply voltage variation is within the rating.
● If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
● Use a power supply unit conforming to the EMC Directive and the Low Voltage
Directive. (Only for use in Europe)
● Use a power supply unit conforming to CLASS 2. (Only for use in the United States)
● Use a power supply unit with an output holding time of 20ms or more.
● Do not use during the initial transient time (approx. 300ms) after the power
supply is switched ON.
● Make sure to use an isolation transformer for the DC power supply. If an auto-transformer
(single winding transformer) is used, this product or the power supply may get damaged.
● In case a surge is generated in the used power supply, connect a surge ab-
sorber to the source and absorb the surge.
● Make sure that the power is OFF while wiring.
● Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
● In order to reduce noise, make the wiring as short as possible.
● Do not use this product in places having excessive vapor, dust, etc.
● Take care that the product does not come in contact with oil, grease, or or-
ganic solvents such as thinner, etc.
● Do not hit the product by a hammer etc. when mounting, as the product get damaged.
● This product is suitable for indoor use only.
9
INTENDED PRODUCTS FOR CE MARKING
● The models listed under "
SPECIFICATIONS" come with CE Marking.
As for all other models, please contact our office.
● Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
For sales network, please visit our website.
PRINTED IN JAPAN
Countermeasure
Check the wiring of output.
Place the product so that extraneous light
is not received at its sensing surface.
Check that there is no noise around the
product. Also check the environment for
power supply and wiring.
In case the product does not operate normally
after checking the above measures, contact
Panasonic Industrial Devices SUNX Co., Ltd.
2s
Optical touch switch
SW-101
: When an object is detected (light is blocked): OFF /
When an object is not detected (light is received): ON
When an object is not detected (light is received): OFF
Incorporated
30 to 85% RH, Storage: 30 to 85% RH
Approx. 130g