Viking K-1900-6-IP Product Manual page 13

Table of Contents

Advertisement

14. Relay Mode
Doorstrike Mode: When programmed for Doorstrike Mode the relay is intended for door strike, maglock or gate control.
The relay will momentarily activate for the preprogrammed relay activation time after detecting the correct relay activation
command (one or two digit touch tone) from the called party.
Outbound Call Mode: When programmed for Outbound Call Mode the relay will activate continuously for the duration of
any outbound call from the Entry phone.
Inbound/Outbound Call Mode: When programmed for Inbound/Outbound Call Mode the relay will activate continuously
for the duration of any inbound or outbound call to or from the Entry phone. This mode is useful for turning on IR flood lights,
for VoIP phones with cameras, etc.
Doorbell Mode: When programmed for Doorbell Mode the relay will momentarily activate the relay for the preprogrammed
relay activation time on any outbound call from the Entry phone. This mode is useful for activating a door chime, etc. When
activating door chimes, a 0.5 - 1 second relay activation time is recommended.
Alarm Mode: When programmed in Alarm Mode the relay will activate continuously while the Entry phone is powered and
registered to the SIP server. In the event the unit loses power and/or SIP registration the relay will turn off, which can be used
to signal an alarm device.
Ring Mode: When programmed for Ring Mode the relay will continuously activate when an inbound call is ringing to the
entry phone. This mode is useful for activating a Viking model SL-2 strobe light, etc.
Note: Inbound Call Mode must be set to Ring Low or Ring High.
Ring Flash Mode: When programmed for Ring Flash Mode the relay will momentarily turn on and off in a 400ms on/off
cadence when an inbound call is ringing to the entry phone. This mode is useful for activating a Viking LPL-1 Remote Visual
Indicator, etc.
Note: Inbound Call Mode must be set to Ring Low or Ring High.
15. Relay Activation Command
The one or two digit code stored in the Relay Activation Command is the touch tone command that the person being
called must enter on their phone in order to momentarily activate the relay to control a doorstrike, mag-lock, gate
controller, or other device. The code can contain 0 - 9, # or Q. The code cannot match a relay latching or toggle
command (11, 10, 1#) unless latching commands are disabled. The code must be entered while the remote phone is
communicating with the Entry phone. The Entry phone determines which direction the touch tone is coming from and
only responds to touch tones from the called phone. The factory setting is QQ.
16. Relay Activation Time
The value stored in the Relay Activation Time is the amount of time the relay will be energized after a correct momentary
touch tone command is entered. This number can range from 0.5 to 99 seconds. The factory setting is 5 seconds. THis
also controls the length of relay closure in "Door Bell " Mode.
17. Relay Internal / External
With the relay set to "Internal" the K-1900-6/7-IP will activate its on board relay for door strike / gate control. The relay
should be set to "External" for higher security installations when using a remote Viking model RC-4A relay controller
to activate the door strike / gate controller (see page 6). NOTE: The internal relay will follow the action of the external
relay if used.
18. Relay Latch Commands (Enable / Disable Relay Latching Commands)
When programmed to "Enable" (factory default) the Remote Access Operation Commands to Un-Latch, Latch or toggle
the relay are enabled. The relay mode must be set to doorstrike to use the commands.
When programmed to "Disable" the Remote Access Operation Commands to Un-Latch, Latch or toggle the relay are
disabled. Disabling the Latch commands can be useful in applications where you want to eliminate the possibility of
inadvertently entering a latch command leaving a gate open/closed, etc.