Charcoal filter (filter version only)
Fig. 16
Charcoal filter - Type 20 LONG LIFE -
Washable activated charcoal filter
The charcoal filter can be washed once every
two months using hot water and a suitable
detergent, or in a dishwasher at 65°C (if
the dishwasher is used, select the full cycle
function and leave dishes out).
Eliminate excess water without damaging
the filter, then remove the mattress located
inside the plastic frame and put it in the oven
for 10 minutes at 100° C to dry completely.
Replace the mattress every 3 years and
when the cloth is damaged.
Type 15 ­ NON­washable activated charcoal
filter
The saturation of the charcoal filter occurs
after more or less prolonged use, depending
on the type of cooking and the regularity of
cleaning of the grease filter. In any case it is
necessary to replace the cartridge at least
every four mounths.
The charcoal filter may NOT be washed or
regenerated.

Replacing lamps

Disconnect the hood from the electricity.
Warning! Prior to touching the light
bulbs ensure they are cooled down.
Remove the damaged light and replace it
with a new one (see the table below):
Lamp
Power (W)
Voltage (V)
220-240
ILCOS D Code
(according IEC 61231)
DRBB/C-3-220-240-E14-35/102
progress 15
Socket
E14
3
Dimension (mm)
35x102
(Diameter x Lenght)

Advertisement