Problem
Possible Causes
Icemaker is not
Demand exceeds ice storage
making enough
capacity.
ice.
House water supply is not
connected, valve is not turned
on fully, or valve is clogged.
Water filter has been
exhausted.
Low house water supply
pressure.
Reverse Osmosis filtration
system is used.
Tubing connecting fridge to
house supply valve is kinked.
TROUBLESHOOTiNg
Solutions
The icemaker will produce approximately 50~80
cubes in a 24 hour period.
Connect the fridge to a cold water supply with
adequate pressure and turn the water shutoff
valve fully open.
If the problem persists, it may be necessary to
contact a plumber.
It is recommended that you replace the water
filter:
Approximately every six months.
When the water filter indicator turns on.
When the water dispenser output decreases.
When the ice cubes are smaller than normal.
The water pressure must be between 20 and 120
psi on models without a water filter and between
40 and 120 psi on models with a water filter.
If the problem persists, it may be necessary to
contact a plumber or install a booster pump to
compensate for the low pressure.
Reverse osmosis filtration systems can reduce
the water pressure below the minimum amount
and result in icemaker issues.
(Refer to Water Pressure section.)
The tubing can kink when the fridge is moved
during installation or cleaning resulting in reduced
water flow. Straighten or repair the water supply
line and arrange it to prevent future kinks.