Wiring Diagram - Panasonic PSCFV11VH2 Installation Instructions Manual

Ventilating fan
Table of Contents

Advertisement

GENERAL SAFETY INFORMATION CONTINUED
WARNING:
To reduce the risk of fire, electric shock or injury to persons, observe the following:
A.
Use this unit only in the manner intended by the manufacturer. If you have any questions, please contact
the manufacturer.
B.
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction. Neither unauthorized modification, repair nor
disassembly is allowed.
C.
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel
buming equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and
safety standards such as those published by the National Fire Protection Association (NFPA), and the
American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
D.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
E.
Ducted fans must always be vented to the outdoors.
F.
Solid state controls may cause harmonic distortion which can cause motor humming noise. To reduce the
risk of fire or electric shock, do not use this unit with any solid-state control device.
G.
Before servicing or cleaning unit, switch power off at service panel and lock panel cabinet to prevent
power from being switched on accidentally. If the panel cabinet cannot be locked, securely fasten a
clearly visible warning label to the service panel.
H.
Never place a switch where it can be reached from a tub or shower.
I.
Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for
installation in Canada only.)
J.
Use only on 20 ampere branch circuit.

WIRING DIAGRAM

Circulating fan unit
Black
Black
Red
Motor(C)
PCB
White
White
Ventilating fan unit
Red
Capacitor
White
Motor(V)
Black
Junction box
Green
Earth ground
Power Supply
AC120V 60Hz
Fuse
Thermal cut-off
o
o
(20A)
(230 F (110 C))
Heater
(1400W)
Thermostat
o
o
(140 F (60C))
Power Supply
AC120V 60Hz
Circulating fan unit
Black
Black
Red
PCB
Motor(C)
White
White
Ventilating fan unit
Red
Capacitor
White
Motor(V)
Black
Junction box
Green
Earth ground
Power Supply
Power Supply
AC120V 60Hz
AC120V 60Hz
Lighting unit
Fuse
Thermal cut-off
Fluorescent lamp
o
o
(20A)
(230 F (110 C))
Heater
(1400W)
Thermostat
o
o
(140 F (60 C))
Electronic
ballast
Night lamp
Power Supply
AC120V 60Hz

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fv-11vhl2Fv-11vh2Pscfv11vhl2

Table of Contents