1. Remove existing toilet and prepare installa-
tion surface.
• Shut off toilet supply and flush tank completely.
• Disconnect and remove supply line.
• If replacing a toilet remove old toilet and existing wax
ring. Cover/plug floor waste opening.
• Clean any old wax or debris from from installation area.
**NOTE: Installation surface must be clean
and level before new toilet is installed.**
• Confirm that current supply location coincides with
desired toilet location and rough-in dimensions.
Supply relocation may be necessary for proper toilet
installation.
• Position toilet template on finish floor making sure it
aligns with current waste location; tape template se-
curely to floor.
2. Turn toilet on its side (please protect the
ground surface with soft material to prevent
damage to toilet), and press new wax seal firm-
ly around waste flange. Apply a small bead of
silicone sealant around toilet base.
Wax Seal
Sealant
3. Install T-bolts in correct floor position and
fasten closet flange.
Closet Flange
4. Position toilet squarely with wall and align
toilet with closet flange.
Slowly lower toilet down onto closet flange
making sure base mounting holes are aligned
with mounting anchors on finished floor.
5. Press toilet down firmly on wax ring and
flange until toilet is securely seated on floor.
T-Bolt