Sapho BH7001-1 Owner's Manual page 10

Table of Contents

Advertisement

Available languages

Available languages

LEAK TEST
1. Perform a leak test in a well-ventilated area outside.
2. Make sure any open flames or cigarettes are extinguished.
3. Remove the battery.
4. Ensure the burner control knob is in the "OFF" position
5. In a bowl, create a soap solution using 1 part water and 1 part liquid detergent
6. Apply the soapy water solution to all connections.
7. Open LP tank valve.
8. A gas leak will be detected by expanding bubbles originating from the point of the leak.
9. If a leak is found at any connection point or if you smell gas, close the tank valve,
disconnect the tank and do not use the appliance until repairs can be made.
TO LIGHT
TIPS: Before Beginning ●Read and understand the instructions thoroughly.
1. Locate the burner control knob and make sure it is in the "OFF"
position.
2. Connect propane (LP) cylinder. (See above pages).
3. Open LP tank valve slowly.
4. Push in igniter button to create sparks at the electrode and hold.
5. Push and turn burner control knob counterclockwise to the
"PILOT" position. Continue to push the control to light the pilot
flame.
Note: For initial start or after any cylinder change, hold
Control Knob IN for 2 minutes to purge air from gas lines
before proceeding
6. After ignition, release the igniter button. Continue to push the
control knob for 45 seconds.
7. If ignition does NOT immediately take place on pilot burner in
seconds, turn the burner control knob to "OFF", wait 5 minutes
for gas to clear and repeat the lighting procedure. If pilot still will
not light, refer to the Troubleshooting Section.
8. Once the pilot is lit, turn the burner control knob to
"High" and "Low" positions. Main burner will light
immediately. If not, turn the burner control knob to
"OFF", wait 5 minutes for gas to clear and repeat the
lighting procedure. If main burner still will not light,
refer to the Troubleshooting Section.
9. Flame height can be changed by adjusting
the burner control knob between the "High"
and "Low" positions.
10. Always check burner and pilot flames
periodically to ensure proper operation.
Flames should be mostly yellow with some
blue for best performance. (See diagrams)
If the burner does not ignite with the burner control valve open, gas will continue to flow out
of the burner and could accidentally ignite causing injury or property damage.
●Check and make sure that all parts are present.
●For future reference, save this instruction sheet.
.
CAUTION
Note: This appliance is
equipped with a Pilot Light
that allows for safer start-
ups and shutdowns. Pilot
must be lit before Main
Burner can be started.
Main Burner Flame
Pilot Flame
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

67504

Table of Contents