1
STATUS INDICATOR: GREEN LED indicates unit in Operation.
2
FAULT INDICATOR: RED LED lights indicating overload or short circuit.
3
INPUT TERMINALS
4
OUTPUT TERMINALS
Input Voltage Range
Output Voltage
Continuous Output Current
Maximum Output Current at 30% Duty
Cycle
No Load Current
Ripple & Noise ( P-P )
Ripple & Noise ( RMS )
Load Regulation
Line Regulation
Efficiency
Protections
Indicators
Input and Output Connection type
Cooling System
Max. Operating Temperature
Dimension ( WxHxD )
Weight
Accessory
Control Panel And Indicators
Specifications
Reverse Polarity, Overload, Short Circuit,
18VDC to 38VDC
13.2VDC
18A
20A
<100mA
<300mV
<25mV
<100mV
<50mV
>90%
OVP (Output Over Voltage Protection),
Overvoltage Protection
Green LED-OPERATE and
Red LED-FAULT
Quick-Connect Terminals
Natural Convection
50°C
162x75x32mm
365g
Mounting Bracket, Quick-connect crimp
connectors, Screws