Circuit-test PDC-6205 Operation Manual

Circuit-test dc - dc converter 13.8vdc @ 5a/ 7a/ 12a

Advertisement

Quick Links

CIRCUIT-TEST
DC - DC Converter
OPERATION
MANUAL
PDC-6205
13.8VDC @ 5A
PDC-6207
13.8VDC @ 7A
PDC-6212
13.8VDC @ 12A
1

Advertisement

loading

Summary of Contents for Circuit-test PDC-6205

  • Page 1 CIRCUIT-TEST DC - DC Converter PDC-6205 13.8VDC @ 5A PDC-6207 13.8VDC @ 7A PDC-6212 13.8VDC @ 12A OPERATION MANUAL...
  • Page 2 Over Voltage Protection: When the output voltage reaches the maximum limit, the over voltage protection is activated and the output voltage shuts down. For PDC-6205, internal input fuse will blow and all indicators will turn off. For PDC-6207 & 6212, protection is maintained even though output load is removed.
  • Page 3: Specifications

    Control Panel and Indicators STATUS INDICATOR: GREEN LED indicates unit in Operation. FAULT INDICATOR: RED LED lights indicating overload or short circuit. INPUT TERMINALS OUTPUT TERMINALS Specifications Models PDC-6205 PDC-6207 PDC-6212 Input Voltage Range 18VDC to 38VDC Output Voltage 13.8VDC...
  • Page 4: Installation And Operation

    Crimp the input and output cables with the included quick-connect crimp connectors. Use different colored cables for clear identification of the inputs, outputs & polarities. Note: Recommended wire gauge sizes are at least 18 AWG for PDC-6205, 16 AWG for PDC-6207 and 14 AWG for PDC-6212.