5.3 Displayed Parameter description

Name
System Starting
Suspend Page
Main Page
1.Disp
Parameters
www.questtel.com
L-RF-EDFA-18dBm
display
QuestTel
L-RF-EDFA-18dBm
xxxxxxx
In: xx.x out: xx.x
Unit: dBm
1.Disp Parameters
2.Set Parameters
3.Alarm Status
Input Power: xx.x dBm
Output Power: xx.x dBm
Output ATT: x.x dBm
Pump1 Bias: x mA
Pump1 Temper: xx.x° C
Pump1 Tec: x.xx A
Pump2 Bias: x mA
Pump2 Temper: xx.x ° C
Pump2 Tec: x.xx A
+5V Read: x.x V
-5V Read: -x.x V
System Temper: xx.x ° C
Serial NO.: xxxxxxxx
IP Addr: xxx.xxx.xxx.xxx
Mask: xxx.xxx.xxx.xxx
Gateway: xxx.xxx.xxx.xxx Gateway
Mac: xxxxxxxxxxxx
Trap Addr1:
xxx.xxx.xxx.xxx
Trap Addr2:
xxx.xxx.xxx.xxx
Firmware Ver: Vx.xx
- 8 -
EDFA Optical Amplifier User Manual
discription
Display logo.
Display model number.
Start countdown / lock status.
Display the input / output optical power
Entry of parameter display menu
Entry of parameter setting menu
Entry of alarm information menu
Input power, accurate to 0.1 dBm
Output power, accurate to 0.1 dBm
Output power ATT, accurate to 0.1 dBm
Bias current of pump1, accurate to 1mA
Temperature of pump1, accurate to 0.1° C
Cooling current of pump1, accurate to 0.01 A
Bias current of pump2, accurate to 1m A
Temperature of pump2, accurate to 0.1 ° C
Cooling current of pump2, accurate to 0.01 A
+5V power supply voltage , accurate to 0.1 V
-5V power supply voltage , accurate to 0.1 V
Chassis temperature, accurate to 0.1 ° C
Device serial number
IP address
Subnet mask
Physical address
trap1 address
trap2 address
Firmware Version number
sales@questtel.com