6. Installation debugging

6.1 Unpack and Check

1. Insure the package is not defaced. If it has any damage or water mark, please
contact local agency or carrier.
2. After unpacking, check equipments and accessories according to package list. Any
question, please contact local agency or our company.
3. If you think the equipment has been damaged, please don't electrify to avoid
worse damage. Please contact local agency or our company in time.

6.2 Instruments and Tools

1. An optical power meter;
2. A digital multimeter;
3. A standard optical fiber test jumper (FC/APC or SC/APC);
4. Some absolute alcohol and medical cotton wool.

6.3 Installation Steps

1. Before installing the equipment, please read the <User's manual> carefully and
install the equipment according to the <User's manual>. Note: For the man-made
damage and other all consequence caused by error installation that not according
to the <User's manual>, we will not be responsible and will not supply free
warranty.
2. Take out the device from the box; fix it to the rack and reliably grounding. (The
grounding resistance must be < 4Ω).
3. Use the digital multimeter to check the supply voltage, make sure the supply
voltage comply with the requirements and the switch key is on the "OFF"
position. Then connect the power supply.
4. Input the optical signal according to the display message. Turn the switch key to
the "ON" position and observe the front panel LED status. After the pump
working status indicator turn into green, the device is working normal. Then press
the menu button on the front panel to check the working parameters.
5. Connect the optical power meter to the optical signal output end by the standard
optical fiber test jumper, then measure the optical output power. Affirm the
measured optical output power and the displayed power are the same and have
reached the nominal value. (Affirm the optical power meter is on 1550nm
wavelength test position; the optical fiber test jumper is the matched one and on
the connector surface has no pollution.) Remove the standard optical fiber test
jumper and optical power meter; connect the device to the network. So far, the
device has been completely installed and debugged.
www.questtel.com