Nozzle Ring Compression Pd; Table 39 Permitted Nozzle Ring Com - ABB HT563462 Operation Manual

Table of Contents

Advertisement

Operation Manual / 4 Product description / A130-M.. - A145-M..
8
Dismantling and fitting
8.12

Nozzle ring compression PD

For the nozzle ring (56001) to be fixed during operation, it must be clamped between the heat
shield (42400) and the turbine casing (51000).
Figure 42: Nozzle ring compression PD
Product
A130
A135
A140
A145
Table 39: Permitted nozzle ring compression PD
42001
Bearing casing
42400
Heat shield
1. Measure dimensions A, B, and S on cleaned surfaces.
2. Calculate compression (PD).
If the calculated value (PD) lies outside the specified range, contact an ABB Turbocharging
Service Station.
© Copyright 2016 ABB. All rights reserved.
Compression PD [mm]
51000
Turbine casing
56001
Nozzle ring
HZTL4031_EN
Page 90 / 117
-0.15 ... 0.15
-0.16 ... 0.16
-0.16 ... 0.16
-0.16 ... 0.16
Revision D
June 2016