Dip Switch Features - Calimet CM3-DCFP Instruction Manual

Table of Contents

Advertisement

Features

DIP Switch Features

There are 6 dip switches located at the bottom of the circuit board. Each switch has a
different feature.
1. CL-DELAY: Gate Closing delay, switch to ON position, turn timer to 1- 6 seconds.
2.TIMER: 1-60 Timer: Auto activated to close gate upon set time ( 1~ 60 seconds).
3. OSC: Remote control priority. Allow remote control to direct gate movement whenever gate is
moving in any direction. Use first signal to stop gate, use second signal to move gate to opposite
direction.
4. 1 PASS: Anti-tailgating system - When ON, after a vehicle has cleared the safety loop, the gate will
start to close immediately. If a second vehicle crosses the loop while the gate is closing, the gate
will stop. The second vehicle must get off the loop before the gate closes completely.
5. SLAVE: Secondary operator activation
6. OPEN L/R: Choose gate open direction Left or Right.
Figure 17 DIP switch
16