KTM META SYSTEM DEF-COM T Manual

KTM META SYSTEM DEF-COM T Manual

Motorcycle alarm

Advertisement

Quick Links

V81548A Is.Uso Def-Com3 KTM
EN

SIGNALS

EN
S
TATUS OF CENTRAL UNIT
Arming by remote control
Arming without internal lift and tilt sensor
Arming with open contact
Testing during the initial immunity phase
Central unit armed
Alarm cycles
Disarming without alarms
Disarming when the motorcycle's battery is flat
Disarming when alarms have been memorised
M
EMORISED ALARMS
Internal movement sensor
Contacts
Ignition sensing
Tampering with cables or battery
If various alarms have been triggered, the memory will signal them in a sequence with 3 second
pauses and will repeat the sequence every 6 seconds.
The memory is reset when the motorcycle is started up or when the alarm system is armed
with the remote control again.
The acoustic signal emitted when the alarm is armed and disarmed fails to comply with the national
norms in Germany and must therefore be disabled.
23-11-2006
16:28
Pagina 10
MotorCycle Alarm
DEF•COM T
LED
Slow flashing
Flashing
On fixed during initial immunity phase
Flashing
Reversed flashing
Reversed flashing
Flashing
Flashing
Switches off
Switches off
Switches off briefly every 6 sec.
10
by
D
I
IRECTION
NDICATORS
S
IREN
1 short flash
1 B
EEP
2 flashes
2 B
EEP
flashes 2 + 1
B
2 + 1
EEP
2 flashes
2 B
-1 B
EEP
OOP
1 B
EEP
lampeggianti
Sounds
1 flash
1 B
EEP
4 B
EEP
1 B
- 1 B
EEP
OOP
LED
SIGNALS
1 flash
2 flashes
3 flashes
4 flashes
BUTTON B
BUTTON A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the META SYSTEM DEF-COM T and is the answer not in the manual?

Questions and answers

Summary of Contents for KTM META SYSTEM DEF-COM T

  • Page 1 V81548A Is.Uso Def-Com3 KTM 23-11-2006 16:28 Pagina 10 MotorCycle Alarm DEF•COM T SIGNALS TATUS OF CENTRAL UNIT IRECTION NDICATORS IREN Passive arming (only if programmed) Slow flashing 1 short flash Arming by remote control Flashing 2 flashes Arming without internal lift and tilt sensor...
  • Page 2 V81548A Is.Uso Def-Com3 KTM 23-11-2006 16:28 Pagina 11 PASSIVE ARMING (only if programmed) The central unit arms automatically in 50 seconds: - After the motorcycle’s key has been turned OFF, or - After the remote control has been pressed to disarm the alarm system, or - After the alarm system has been disarmed using the ‘override’...
  • Page 3 V81548A Is.Uso Def-Com3 KTM 23-11-2006 16:28 Pagina 12 PROTECTION BY THE ALARM SYSTEM The alarm central unit protects the motorcycle against being started and an alarm cycle will be triggered every time: - the ignition key is turned ON - an attempt is made to remove or move any part of the motorcycle which is protected by specific switches (for example if the seat or the storage compartment is opened …...
  • Page 4 V81548A Is.Uso Def-Com3 KTM 23-11-2006 16:28 Pagina 13 SPECIAL FUNCTIONS – CONFIGURATION It is possible to set some alarm functions to adapt the alarm system to the motorcycle and its driver’s needs. To set the functions, which are described in the table below, proceed as follows: 1.
  • Page 5 V81548A Is.Uso Def-Com3 KTM 23-11-2006 16:28 Pagina 14 ‘OVERRIDE’ EMERGENCY CODE If a remote control is lost, stolen or damaged, it is possible to disarm the alarm system with a 5 digit emergency code called the ‘OVERRIDE’ code. The code is found on the label supplied with the remote controls.
  • Page 6 V81548A Is.Uso Def-Com3 KTM 23-11-2006 16:28 Pagina 15 CUSTOMISING THE ‘OVERRIDE’ CODE It is possible to customise the ‘override’ code so that it is easier to remember in case of emergency. Proceed as follows: WITHIN WITHIN WITHIN ‘OVERRIDE’ WITHIN WITHIN...
  • Page 7 V81548A Is.Uso Def-Com3 KTM 23-11-2006 16:28 Pagina 16 RESTORING THE DEFAULT OVERRIDE CODE Should the driver forget or lose the override code for the product, the ‘11111’ default override code can be restored provided he has two remote controls. Follow the procedure below to do this: Disarm the product using the remote control, turn the motorcycle’s ignition key to ON and press button A alternately on both remote...
  • Page 8 V81548A Is.Uso Def-Com3 KTM 23-11-2006 16:28 Pagina 17 SPECIFICATIONS Power supply 12Vcc (10V-15V) Consumption 1,8 mA Consumption in Stop mode 0 mA Operating temperature - 25°C + 85°C Sound level of siren (1 m) 114 dB Self-supply autonomy 5 minutes...

Table of Contents