User Manual Rechargeable Smart Lithium Ion Battery Reference Part Numbers for Battery Model SE-2030 SE-2030 SE20300NR29 14.4V 5.7AH, 82.08Wh User’s Manual Statement of Confidentiality The information contained within this document is confidential and proprietary to Sealed Energy Systems. This information should not, in whole or in part, be reproduced, disclosed or used except as expressly and duly authorized by Sealed Energy Systems.
Lithium Ion battery SE-2030 by Sealed Energy Systems (SES®). This specification is the interface Certificate of document between SES® and its customers. It is understood that the compliance, EU REACH customer may create their own internal specification. However, this Regulation no.
User Manual In the event of a battery leaking, do not allow the liquid to come in contact with the skin or eyes. If contact has been made, wash the affected area with copious amounts of water and seek medical advice. Keep batteries clean and dry. Secondary batteries need to be charged before use.
User Manual 2.3.4 Disposal universal/hazardous waste regulations further information regarding disposal of spent batteries. If the internal cells are leaking/broken open, consult hazardous Regulations vary for different countries. Dispose of in waste regulations under US Environmental Protection accordance with local regulations. Agency’s Resource Conservation and Recovery Act Intact, spent batteries are not considered to be hazardous ...
User Manual appropriate collection site accordance with government regulations. Japan: Recycling of expended lithium-ion battery packs is regulated by the Wastes Disposal and Public Cleaning Law and the Law for Promotion of Effective Utilization. Brazil: Expended battery packs should recycled accordance to the Natation Solid Waste Policy (PNRS) or 3 REQUIREMENTS CONAMA in compliance with the directives and...
Page 7
User Manual 3.1.4. Discharge -20ºC to +60ºC Discharge Temperature Limits: As shown below, ≤ 80%RH The battery shall be capable of continuous discharge within the Operating Boundary as shown in the graph below. Host devices should be designed for a controlled shutdown following battery notification of termination by the battery sending TERMINATE_DISCHARGE alarm, prior to protection circuit cut-off.
Page 8
User Manual 3.1.5. Charge 0ºC to 45ºC Charge Temperature Limits: As Shown below, ≤80%RH The battery shall be capable of continuous charge at 16.8V, as shown in the graph below. A dedicated level II or level III smart battery charger is required to charge the battery. Using this type of charger, the battery will request appropriate charging Voltage and Current from the smart battery charger.
User Manual 3.1.6. Storage require separate pull-ups to system logic voltage, NOT the battery voltage. Typically, a 10KΩ pull-up resistor is used, but Storage Temperature Limits: -20°C to 60°C, ≤80%RH please refer to the SMBus Specification for additional info. The battery should be stored in an environment with low ...
Page 10
User Manual performance of the battery. It’s primary functions are to provide down the micro- controller and all associated circuitry. If this fuel gauging and software based charge control, and to ensure should happen, the battery will require an initial low current safe operation throughout the life cycle of the battery.
User Manual 3.2.2. DC Specifications The internal pack temperature is measured by an NTC thermistor attached to the cell stack. Temperature readings have a resolution of 0.1°K. The absolute PARAMETER LIMITS REMARKS accuracy is ±3°K over an operating range of -20°C to When a host is detected +80°C.
User Manual 3.3.4. SMBus Host-to-Battery MessageProtocol Data Data Battery Command Battery Wr A Rd A Byte Byte PEC !A The Bus Host communicates with the battery pack using one of three Address Code Address High protocols: Write Word Protocol w/PEC •...
User Manual Data Data Byte Data Data Data Battery Command ≈ Byte Byte count =N Byte 1 Byte 2 Byte N Address Code High Block Read Read Word Protocol w/PEC SMBus Host (Master) Smart Battery (Slave) Battery Address Wr Command Code Battery Address Rd 3.3.4.3.Block Read The Block Read begins with a slave address and a write condition.
User Manual Target Battery Data Byte Data Byte Charger Command Data Byte Data Byte Address Address High Address Code High Battery Critical Message Battery Broadcast Message for the Charger Data Data Data Data Target Battery Charger Command Byte Byte Byte Byte Address Address...
Page 16
User Manual Host-to-Battery Messages Command Default Command Default Function Description Unit Access Function Description Unit Access Code (POR) Code (POR) Manufacturer Returns the battery’s voltage (measured 0x00 Voltage () 0x09 Access() at the cell stack) Remaining 0x01 Remaining Capacity Alarm Threshold Returns the current being supplied (or Capacity Alarm() Current ()
Alarm Warning() message to the Host and/ or Returns a character array that contains Device Name() 0x21 string SE-2030 the battery’s name. Charger. The Battery broadcasts the Alarm Warning() message at 10 Returns a character array that contains second intervals until the critical condition(s) has been corrected.
Page 18
User Manual Battery Critical Messages Action When Battery Status Set When: Cleared When: Set: Command Function Description Unit Access Relative State of Charge() <= Relative State Of Code 0%, Cell Under-Voltage (CUV) Charge() >= 1%, CUV, This message is to the host and/or charger to Alarm Over-Current Discharge OCD or OTD recovery...
Current() =>2.9A*. Then, once the Average Current() <= are non-resettable). 200mA for 70sec, the battery will re-test the over-current condition, and again allow charging. *Note: Current values vary time to time. Check SDS with SES® SEALED ENERGY SYSTEMS ®...
User Manual 3.4.3. Discharge Protection 3.4.4. Short Circuit Protection The primary protection circuit will prohibit the discharge of Under-Voltage: the battery if a short-circuit is placed across the battery+ / - The primary protection circuit will prevent the battery from terminals.
User Manual 3.5. Passive Safety Protection 3.7. Environmental/Safety Specifications 3.5.1. Overview of Operations 3.7.1. EMC and Safety The battery pack is fitted with additional components to protect it The battery complies with the following: • EMC Directive 2004/108/EC against abusive charge and discharge conditions. These are in •...
User Manual 3.8. Reliability 3.8.1. Life Expectancy Given normal storage & usage, user can expect the battery to deliver 4560mAh or more after 1000 charge/discharge cycles where the charge phase is CC/CV C/3, 16.8±0.05V and the discharge is C/3 down to 3.0V/Cell at 25°C.
User Manual 3.8.3. Shelf Life The batteries are shipped from Sealed Energy Systems with between 20% and 30% rated capacity and this provides a minimum of 6 months’ shelf life, when stored at 25°C. If the storage temperature exceeds 25°C over the 6-month period, then the shelf life will be reduced and provisions should be made to recharge the battery periodically.