Gigabyte G482-Z54 User Manual

Gigabyte G482-Z54 User Manual

Hpc server - 4u dp 8 x gen4 gpu server
Table of Contents

Advertisement

Quick Links

G482-Z54
HPC Server - 4U DP 8 x Gen4 GPU Server
User Manual
Rev. 1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G482-Z54 and is the answer not in the manual?

Questions and answers

Summary of Contents for Gigabyte G482-Z54

  • Page 1 G482-Z54 HPC Server - 4U DP 8 x Gen4 GPU Server User Manual Rev. 1.0...
  • Page 2 GIGABYTE's prior written permission. Documentation Classifications In order to assist in the use of this product, GIGABYTE provides the following types of documentation:  User Manual: detailed information & steps about the installation, configuration and use of this product (e.g.
  • Page 3 Conventions The following conventions are used in this user's guide: NOTE! Gives bits and pieces of additional information related to the current topic. CAUTION! Gives precautionary measures to avoid possible hardware or software problems. WARNING! Alerts you to any damage that might result from doing or not doing specific actions.
  • Page 4 Server Warnings and Cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING! To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
  • Page 5 Electrostatic Discharge (ESD) CAUTION! ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE, PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT- TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER WHEN HANDLING PARTS.
  • Page 6 CAUTION! Risk of explosion if battery is replaced incorrectly or with an incorrect type. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used bat- teries according to the manufacturer’s instructions.
  • Page 7: Table Of Contents

    Table of Contents Chapter 1 Hardware Installation ................... 11 Installation Precautions .................. 11 Product Specifications ..................12 System Block Diagram ................... 15 Chapter 2 System Appearance ..................17 Front View ...................... 17 Rear View ....................... 18 Front Panel Buttons and LEDs ............... 19 Front System LAN LEDs ................
  • Page 8 5-2-2 PSP Firmware Versions ..................52 5-2-3 Legacy Video Select ....................53 5-2-4 AST2500 Super IO Configuration ................54 5-2-5 S5 RTC Wake Settings ...................57 5-2-6 Serial Port Console Redirection ................58 5-2-7 CPU Configuration ....................62 5-2-8 AMI Graphic Output Protocol Policy ...............63 5-2-9 PCI Subsystem Settings ..................64 5-2-10 USB Configuration ....................66 5-2-11 Network Stack Configuration ..................68...
  • Page 9 5-8-1 UEFI NETWORK Drive BBS Priorities ..............133 ..............134 5-8-2 UEFI Application Boot Priorities Save & Exit Menu ..................135 5-10 ABL POST Codes ..................136 5-10-1 StartProcessorTestPoints ..................136 5-10-2 Memory test points ....................136 5-10-3 PMU Test Points ....................136 5-10-4 Original Post Code ....................137 5-10-5 CPU test points .....................138 5-10-6 Topology test points ....................138 5-10-7 Extended memory test point .................138...
  • Page 10 - 10 -...
  • Page 11: Chapter 1 Hardware Installation

    Chapter 1 Hardware Installation Installation Precautions The motherboard/system contain numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the user manual and follow these procedures: • Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or warranty sticker provided by your dealer.
  • Page 12: Product Specifications

    Product Specifications NOTE: We reserve the right to make any changes to the product specifications and product-related informa- tion without prior notice. AMD EPYC™ 7002 series processor family Š Dual processors, 7nm Š Up to 64-core, 128 threads per processor Š...
  • Page 13 Internal I/O 1 x TPM header Š 1 x Front panel header Š Front I/O 2 x USB 3.0 Š 1 x VGA Š 2 x RJ45 Š 1 x MLAN Š 1 x Power button with LED Š 1 x ID button with LED Š...
  • Page 14 Power Supply 3 x 2200W redundant PSUs Š 80 PLUS Platinum Š AC Input: Š 100 - 127V / 14A, 47 - 63Hz 200 - 240V / 12.6A, 47 - 63Hz DC Output: Š Max 1200W/ 100-127V~ +12.12V/ 95.6A +12Vsb/ 3.5A Max 2200W/ 200-240V +12.12V/ 178.1A +12Vsb/ 3.5A...
  • Page 15: System Block Diagram

    System Block Diagram CFPG012 10/100/1G MLAN PHY(1ch) (front side) ASPEED AST2500 (front side) 2 x 1GbE 2-bay 2.5” U.2 8-bay 2.5” SATA BASE-T LAN Intel I350 (front side) 2 x USB 3.0 USB3.0 x2 (front side) SATAIII x8 CPU0 CPU1 xGMI2 18GT/s AMD ROME AMD ROME...
  • Page 16 This page intentionally left blank Hardware Installation - 16 -...
  • Page 17: Chapter 2 System Appearance

    Chapter 2 System Appearance Front View HDD #0 HDD #2 HDD #4 HDD #6 HDD #8 HDD #3 HDD #5 HDD #7 HDD #9 HDD #1 No. Description Description RAID Card Slot USB 3.0 Port x 2 Front Panel LEDs and Buttons VGA Port GbE LAN Port x 2 2.5-inch HDD Bay x 10 (#0 to #9)
  • Page 18: Rear View

    Rear View PSU3 PSU2 PSU1 No. Description Description PCIe x16 Slot x 8 PCIe x16 Slot x 1 System Appearance - 18 -...
  • Page 19: Front Panel Buttons And Leds

    Front Panel Buttons and LEDs No. Name Color Status Description Reset Button Press this button to reset the system. Indicates locating the HDD. Green Blink Indicates accessing the HDD. HDD Status Amber Indicates HDD error. Green / Blink Indicates HDD rebuilding. Amber Indicates no HDD access or no HDD error.
  • Page 20: Front System Lan Leds

    Front System LAN LEDs Name Color Status Description Yellow 1 Gbps data rate GbE Speed Green 100 Mbps data rate 10 Mbps data rate Link between system and network or no access Green GbE Link / Blink Data transmission or reception is occurring. Activity LED No data transmission or reception is occurring.
  • Page 21: Power Supply Unit (Psu) Led

    Power Supply Unit (PSU) LED PSU LED Color Status Description No AC power to all power supplies Green +12V output ON and OK Blinking Green AC present / Only +12VSB on (PS off) or PSU in Smart Standby Mode 0.5Hz Blinking Green Power supply firmware update...
  • Page 22: Hard Disk Drive Leds

    Hard Disk Drive LEDs LED#1 LED#2 HDD Present RAID SKU Rebuilding LED1 Locate HDD Fault Access (No Access) Disk LED Green ON(*1) BLINK (*2) (LED on Back Panel) Amber No RAID configuration Green ON(*1) (via HBA) Removed HDD Slot (LED on Back Panel) Amber Green BLINK (*2)
  • Page 23: Chapter 3 System Hardware Installation

    Chapter 3 System Hardware Installation Pre-installation Instructions System components and electronic circuit boards can be damaged by discharges of static electricity. Working on systems that are still connected to a power supply can be extremely dangerous. Follow the simple guidelines below to avoid damage to your system or injury to yourself. •...
  • Page 24: Removing And Installing The Top Rear Cover

    Removing and Installing the Top Rear Cover Before you remove the top rear cover: • Make sure the system is not turned on or connected to AC power. Follow these instructions to remove the top rear cover: Remove the single screw securing the cover. Loosen the two thumbnail screws securing the top rear cover in place.
  • Page 25: Removing And Installing The Air Duct

    Removing and Installing the Air Duct Before you remove the top rear cover: • Make sure the system is not turned on or connected to AC power. Follow these instructions to remove and install the air duct: Lift up to remove the air duct. To install the air duct, align the rear edge of air duct with the GPU module brackets ensuring that the arrows on the air duct face the rear of the system as shown in the image below, and then push down the air duct into chassis until it firmly seats.
  • Page 26: Installing The Gpu Card (Optional)

    Installing the GPU Card (Optional) Before you install the GPU card: • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered down and all power sources have been disconnected from the server prior to installing a GPU card.
  • Page 27 System Hardware Installation - 27 -...
  • Page 28 System Hardware Installation - 28 -...
  • Page 29: Installing The Pcie Card

    Installing the PCIe Card Read the following guidelines before you begin to install the PCIe Card: • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered down and all power sources have been disconnected from the server prior to installing a PCIe card.
  • Page 30 System Hardware Installation - 30 -...
  • Page 31: Removing And Installing The Heat Sink

    Removing and Installing the Heat Sink Read the following guidelines before you begin to install the heat Sink: • Always turn off the computer and unplug the power cord from the power outlet before installing the heat sink to prevent hardware damage. •...
  • Page 32: Removing And Installing The Cpu

    Removing and Installing the CPU Read the following guidelines before you begin to install the CPU: • Make sure that the motherboard supports the CPU. • Always turn off the system and unplug the power cord from the power outlet before installing the CPU to prevent hardware damage.
  • Page 33 • • When installing the heat sink over the CPU, use T20-Lobe driver to tighten the 4 captive nuts in sequential order (1g2g3g4). • • The screw tightening torque: 16.1 ± 1.2 kgf-cm (14.0± 1.0 lbf-in) System Hardware Installation - 33 -...
  • Page 34: Removing And Installing The Memory

    Removing and Installing the Memory Read the following guidelines before you begin to install the memory: • Make sure that the motherboard supports the memory. It is recommended that memory of the same capacity, brand, speed, and chips be used. •...
  • Page 35: Installing The Memory

    3-7-2 Installing the Memory • Before installing a memory module, make sure to turn off the system and unplug the power cord from the power outlet to prevent damage to the memory module. • Be sure to install DDR4 DIMMs on this motherboard. Follow these instructions to install the Memory: Insert the DIMM memory module vertically into the DIMM slot, and push it down.
  • Page 36 RDIMM Maximum Frequency Supported DIMM Frequency (MT/s) DIMMs 1.2V Populated 3200 3200 2933 2933 2933 3DS RDIMM Maximum Frequency Supported DIMM Frequency (MT/s) DIMMs 2S2R Populated 1.2V 2S4R 2933 2666 LRDIMM Maximum Frequency Supported DIMM Frequency (MT/s) DIMMs 2S2R Populated 1.2V 2S4R 3200...
  • Page 37: Removing And Installing The 2.5" Hard Disk Drive

    Slide the hard drive tray into the bay until it locks in place. CAUTION! We strongly recommend using enterprise level hard disk drives in the Gigabyte server system. For more information of recommended HDDs, please visit the Gigabyte website: https://www.gigabyte.com and search for the specific product QVL from Support & Downloads.
  • Page 38: Replacing The System Fan Module

    Replacing the System FAN Module CAUTION! Before you remove or install the system fans follow these steps: • Make sure the system is not turned on or connected to the AC power. • Disconnect all necessary cable connections. Failure to observe these warnings could result in personal injury or damage to the equipment.
  • Page 39: Removing And Installing The Top

    3-10 Removing and Installing the Top Front Cover Skip this section if you are not going to replace the PCIe RAID card. Follow these instructions to remove the top front cover: Remove the three screws securing the cover. Slide the cover towards the rear and remove the cover in the direction indicated. Reverse the previous steps to install the top front cover.
  • Page 40: Removing And Installing The Power Supply

    3-11 Removing and Installing the Power Supply CAUTION! • In order to reduce the risk of injury from electric shock, disconnect AC power from the power supply before removing the power supply from the system. • Please see Section 2-2 "Rear View" for installation sequence. Follow these instructions to replace the power supply: Flip up and then grasp the power supply handle.
  • Page 41: Cable Connections

    3-12 Cable Connections Motherboard to PCIe Board and Front IO Board and HDD Backplane Board System Hardware Installation - 41 -...
  • Page 42 Motherboard to 2.5" HDD Backplane Board System Hardware Installation - 42 -...
  • Page 43: Chapter 4 Motherboard Components

    Chapter 4 Motherboard Components Motherboard Components CPU0 CPU1 Item Description Item Description 2 x 15 Pin HDD Back Plane Board SlimLine Connectors (PCIe Gen4 Signal) Connector SlimLine Connectors (PCIe Gen4 Signal) SlimLine Connectors (PCIe Gen4 Signal) SlimLine Connectors (PCIe Gen4 Signal) SlimLine Connectors (PCIe Gen4 Signal) SlimLine Connectors (PCIe Gen4 Signal) SlimLine Connectors (PCIe Gen4 Signal)
  • Page 44: Jumper Settings

    Jumper Settings Clear CMOS Jumper CLR_CMOS Enable Default CPU0 CPU1 HSMB_SEL BIOS Defined PMBUS_SEL BIOS Defined BIOS_PWD Clear Supervisor Password Normal (Default) BIOS_RCVR BIOS Recovery Mode Normal (Default) ON OFF Clear CMOS Jumper CLR_CMOS Enable Default Motherboard Components - 44 -...
  • Page 45: Chapter 5 Bios Setup

    Chapter 5 BIOS Setup BIOS (Basic Input and Output System) records hardware parameters of the system in the EFI on the motherboard. Its major functions include conducting the Power-On Self-Test (POST) during system startup, saving system parameters, loading the operating system etc. The BIOS includes a BIOS Setup program that allows the user to modify basic system configuration settings or to activate certain system features.
  • Page 46  Main This setup page includes all the items of the standard compatible BIOS.  Advanced This setup page includes all the items of AMI BIOS special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.) ...
  • Page 47: The Main Menu

    The Main Menu Once you enter the BIOS Setup program, the Main Menu (as shown below) appears on the screen. Use arrow keys to move among the items and press <Enter> to accept or enter other sub-menu. Main Menu Help The on-screen description of a highlighted setup option is displayed on the bottom line of the Main Menu.
  • Page 48 Parameter Description BIOS Information Project Name Displays the project name information. Project Version Displays version number of the BIOS setup utility. Build Date and Time Displays the date and time when the BIOS setup utility was created. BMC Information BMC Firmware Version Displays BMC firmware version information.
  • Page 49: Advanced Menu

    Advanced Menu The Advanced Menu displays submenu options for configuring the function of various hardware components. Select a submenu item, then press <Enter> to access the related submenu screen. When Boot Mode Select is set to UEFI (Default) - 45 - BIOS Setup...
  • Page 50 When "Boot Mode Select" is set to Legacy in the Boot > Boot Mode Select section Parameter Description Enable/Disable ErP Lot 9 suuport. ErP Mode Options available: Enable/Disable. Default setting is Disable. BIOS Setup - 50 -...
  • Page 51: Trusted Computing

    5-2-1 Trusted Computing Parameter Description Configuration Enable/Disable BIOS support for security device. OS will not show security device. TCG EFI protocol and INT1A interface will not be Security Device Support available. Options available: Enable/Disable. Default setting is Enable. Select Enable to activate TPM support feature. SPI TPM Support Options available: Enabled/Disabled.
  • Page 52: Psp Firmware Versions

    5-2-2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information. Items on this window are non-configurable. BIOS Setup - 52 -...
  • Page 53: Legacy Video Select

    5-2-3 Legacy Video Select Description Parameter Selects between onboard or external VGA support. OnBrd/Ext VGA Select (Note) Options available: Auto, Onboard, External. Default setting is Onboard. This configurable option will be displayed when "Boot Mode Select" is set to Legacy in the (Note) Boot >...
  • Page 54: Ast2500 Super Io Configuration

    5-2-4 AST2500 Super IO Configuration Description Parameter AST2500 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1/2 Press [Enter] for configuration of advanced items. Configuration BIOS Setup - 54 -...
  • Page 55 5-2-4-1 Serial Port 1Configuration Description Parameter Serial Port 1/2 Configuration Enable/Disable the Serial Port (COM). When set to Enabled allows you to configure the Serial port 1/2 settings. When set to Disabled, displays no Serial Port (Note1) configuration for the serial port. Options available: Enabled/Disabled.
  • Page 56 Select an optimal settings for Super IO Device. Options available for Serial Port 1: Auto IO=3F8h; IRQ=4; IO=3F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2E8h;...
  • Page 57: S5 Rtc Wake Settings

    5-2-5 S5 RTC Wake Settings Parameter Description Enable/Disable system wake on alarm event. Options available: Disabled/Fixed Time. When Fixed Time enabled, system Wake System from S5 (Note1) will wake on the hr::min::sec specified. Default setting is Disabled. (Note1) Advanced items prompt when this item is defined. - 45 - BIOS Setup...
  • Page 58: Serial Port Console Redirection

    5-2-6 Serial Port Console Redirection Parameter Description Select whether to enable console redirection for specified device. Console redirection enables the users to manage the system from a remote COM1/Serial Over LAN (Note)) location. Options available: Enabled/Disabled. Default setting is Disabled. Press [Enter] to configure advanced items.
  • Page 59 Parameter Description Parity Š – A parity bit can be sent with the data bits to detect some transmission errors. – Even: parity bit is 0 if the num of 1's in the data bits is even. – Odd: parity bit is 0 if num of 1's in the data bits is odd. –...
  • Page 60 Parameter Description Legacy Console Redirection Press [Enter] to configure advanced items. Redirection COM Port Š – Selects a COM port for Legacy serial redirection. – Options available: COM1/Serial Over LAN, COM2. Default setting is COM1/Serial Over LAN. Resolution Š – Selects the number of rows and columns used in Console Legacy Console Redirection Redirection for legacy OS support.
  • Page 61 Parameter Description Flow Control Š – Flow control can prevent data loss from buffer overflow. When sending data, if the receiving buffers are full, a 'stop' signal can Serial Port for Out-of-Band be sent to stop the data flow. Once the buffers are empty, a 'start' EMS Console Redirection signal can be sent to re-start the flow.
  • Page 62: Cpu Configuration

    5-2-7 CPU Configuration Description Parameter Enable/Disable the CPU Virtualization. SVM Mode Options available: Enabled/Disabled. Default setting is Enabled. Controls the Secure Memory Encryption Enable (SMEE) function. SMEE Options available: Enabled/Disabled. Default setting is Enabled. Press [Enter] to view more information related to CPU. CPU 0/1 Information BIOS Setup - 62 -...
  • Page 63: Ami Graphic Output Protocol Policy

    5-2-8 AMI Graphic Output Protocol Policy Parameter Description ASPEED Graphics PCI Adapter ASPEED Graphics Driver Output Select Press [Enter] to select output interface. - 45 - BIOS Setup...
  • Page 64: Pci Subsystem Settings

    5-2-9 PCI Subsystem Settings BIOS Setup - 64 -...
  • Page 65 Description Parameter Displays the PCI Bus Driver version information. PCI Bus Driver Version Change the PCIe lanes. U2_P0_P# Lanes Configuration (Note1) Options available: Disabled, Auto, x16, x8x8, x8x4x4, x4x4x8, U2_P1_P# Lanes Configuration (Note1) x4x4x4x4. Default setting is Auto. When enabled, this setting will initialize the device expansion ROM U2_P0_P# I/O ROM (Note1) for the related PCI-E slot.
  • Page 66: Usb Configuration

    5-2-10 USB Configuration Parameter Description USB Configuration USB Module Version Displays the USB version. USB Controllers Displays the supported USB controllers. USB Devices Displays the USB devices connected to the system. Enable/disable the Legacy USB support fuction. AUTO option disables legacy support if no USB devices are connected.
  • Page 67 Parameter Description USB mass storage device Start Unit command time-out. Device reset time-out Options available: 10 sec/20 sec/30 sec/40 sec. Default setting is 20 sec. Maximum time the device will take before it properly reports itself to the Host Controller. "Auto" uses default value: for a Root port it is 100 ms, for Device power-up delay a Hub port the delay is taken from Hub descriptor.
  • Page 68: Network Stack Configuration

    5-2-11 Network Stack Configuration Parameter Description Enable/Disable the UEFI network stack. Network Stack Options available: Enabled/Disabled. Default setting is Enabled. Enable/Disable the Ipv4 PXE feature. Ipv4 PXE Support (Note) Options available: Enabled/Disabled. Default setting is Enabled. Enable/Disable the Ipv4 HTTP feature. Ipv4 HTTP Support (Note) Options available: Enabled/Disabled.
  • Page 69: Nvme Configuration

    5-2-12 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system - 45 - BIOS Setup...
  • Page 70: Sata Configuration

    5-2-13 SATA Configuration Parameter Description Displays the installed HDD devices information. System will automatically SATA Configuration detect HDD type. BIOS Setup - 70 -...
  • Page 71: Uefi Post Logo Configuration

    5-2-14 UEFI POST LOGO Configuration Parameter Description UEFI Configuration Select output device type. - 45 - BIOS Setup...
  • Page 72: Tls Auth Configuration

    5-2-15 Tls Auth Configuration Parameter Description Press [Enter] for configuration of advanced items. Enroll Cert Š – Press [Enter] to enroll a certificate • Enroll Cert Using File • Cert GUID Server CA Configuration Input digit character in 1111111-2222-3333-4444-1234567890ab format. –...
  • Page 73: Amd Mem Configuration Status

    5-2-16 AMD Mem Configuration Status Description Parameter Press [Enter] to view the memory configuration status related to CPU 0. CPU0/1 - 45 - BIOS Setup...
  • Page 74: Iscsi Configuration

    5-2-17 iSCSI Configuration Parameter Description Press [Enter] and name iSCSI Initiator. Only IQN format is accecpted. iSCSI Initiator Name Range: from 4 to 223 Add an Attempt Press [Enter] to configure advanced items. Delete Attempts Press [Enter] to configure advanced items. Change Attempt Order Press [Enter] to configure advanced items.
  • Page 75: Intel(R) I350 Gigabit Network Connection

    5-2-18 Intel(R) I350 Gigabit Network Connection - 45 - BIOS Setup...
  • Page 76 Description Parameter Press [Enter] to configure advanced items. Link Speed Š – Allows for automatic link speed adjustment. – Options available: Auto Negotiated, 10 Mbps Half, 10 Mbps Full, 100 Mbps Half, 100 Mbps Full. Default setting is Auto Negotiated. Wake On LAN NIC Configuration Š...
  • Page 77: Vlan Configuration

    5-2-19 VLAN Configuration - 45 - BIOS Setup...
  • Page 78 Parameter Description Press [Enter] to configure advanced items. Create new VLAN Š VLAN ID Š – Sets VLAN ID for a new VLAN or an existing VLAN. – Press the <+> / <-> keys to increase or decrease the desired values. –...
  • Page 79: Mac Ipv4 Network Configuration

    5-2-20 MAC IPv4 Network Configuration Parameter Description Indicates whether network address is configured successfully or not. Configured Options available: Enabled/Disabled. Default setting is Disabled. Options available: Enabled/Disabled. Default setting is Enabled. Enable DHCP (Note) Local IP Address Press [Enter] to configure local IP address. (Note) Press [Enter] to configure local NetMask.
  • Page 80: Mac Ipv6 Network Configuration

    5-2-21 MAC IPv6 Network Configuration Parameter Description Press [Enter] to configure advanced items. Displays the MAC Address information. Š Interface ID Š – The 64 bit alternative interface ID for the device. The string is colon separated. e.g. ff:dd:88:66:cc:1:2:3. DAD Transmit Count Š...
  • Page 81: Amd Cbs Menu

    AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU-related information that the BIOS automatically sets. Select a submenu item, then press [Enter] to access the related submenu screen. - 45 - BIOS Setup...
  • Page 82: Cpu Common Options

    5-3-1 CPU Common Options Parameter Description CPU Common Options Performance Press [Enter] for configuration of advanced items. Prefetcher settings Press [Enter] for configuration of advanced items. Core Watchdog Press [Enter] for configuration of advanced items. From a workaround for GCC/C000005 issue for XV Core on CZ A0, setting MSRC001_1029 Decode Configuration (DE_CFG) bit 14 RedirectForReturnDis [DecfgNoRdrctForReturns] to 1.
  • Page 83 Parameter Description SEV-ES ASID Space Limit Space limit control for SEV-ES ASIDs. Control Options available: Auto/Manual. Default setting is Auto. Enable/Disable the Streaming Stores functionality. Streaming Stores Control Options available: Auto, Enabled, Disabled. Default setting is Auto. Sets the Local APIC Mode. Local APIC Mode Options available: Auto, xAPIC, x2APIC.
  • Page 84 5-3-1-1 Performance Parameter Description Performance Allows you to accept or decline enabling Custom Core Pstates. When Custom Core Pstates accepted, you can disable or customize core pstates. Allows you to accept or decline enabling CCDs, processor cores and threads. When accepted, you can control the number of CCDs to be CCD/Core/Thread Enablement used, the number of cores to be used, and whether to enable or disable Simultaneous Multithreading Technology (SMT) support.
  • Page 85 5-3-1-2 Prefetcher Settings Parameter Description Prefetcher settings Enable/Disable L1 Stream HW Prefetcher. L1 Stream HW Prefetcher Options available: Auto, Enable, Disabled. Default setting is Enable. Enable/Disable L2 Stream HW Prefetcher. L2 Stream HW Prefetcher Options available: Auto, Enable, Disabled. Default setting is Enable. - 45 - BIOS Setup...
  • Page 86 5-3-1-3 Core Watchdog Parameter Description Core Watchdog Enable/Disable CPU Watchdog Timer. Core Watchdog Timer Enable Options available: Auto, Enabled, Disabled. Default setting is Auto. BIOS Setup - 86 -...
  • Page 87: Df Common Options

    5-3-2 DF Common Options Parameter Description DF Common Options Scrubber Press [Enter] for configuration of advanced items. Memory Addrssing Press [Enter] for configuration of advanced items. ACPI Press [Enter] for configuration of advanced items. Link Press [Enter] for configuration of advanced items. Enable/Disable SyncFlood to UMC &...
  • Page 88 5-3-2-1 Scrubber Parameter Description Scrubber Provide a value that is the number of hours to scrub memory. DRAM scrub time Options available: Auto, Disabled, 1 hour, 4 hours, 8 hours, 16 hours, 24 hours, 48 hours. Default setting is Auto. Enable/Disable the Poison scrubber control feature.
  • Page 89 5-3-2-2 Memory Addressing Parameter Description Memory Addressing Specifies the number of desired NUMA nodes per socket. NUMA nodes per socket Options available: Auto, NPS0, NPS1, NPS2, NPS4. Default setting is Auto. Enable/Disable the Memory interleaving feature. Memory inerleaving Options available: Auto/Disabled. Default setting is Auto. Controls the memory interleaving size.
  • Page 90 5-3-2-3 ACPI Parameter Description ACPI ACPI SRAT L3 Cache As Enable/Disable the ACPI SRAT L3 Cache As NUMA Domain function. Options available: Auto, Enabled, Disabled. Default setting is Auto. NUMA Domain Determines how the SLIT distances are declared. ACPI SLIT Distance Control Options available: Auto/Manual.
  • Page 91 5-3-2-4 Link Parameter Description Link Enable/Disable GMI link encryption. GMI encryption control Options available: Auto, Enabled, Disabled. Default setting is Auto. Enable/Disable xGMI link encryption. xGMI encryption control Options available: Auto, Enabled, Disabled. Default setting is Auto. CAKE CRC perf bounds Options available: Auto/Manual.
  • Page 92: Umc Common Options

    5-3-3 UMC Common Options Parameter Description UMC Common Options DDR4 Common Options Press [Enter] for configuration of advanced items. DRAM Memory Mapping Press [Enter] for configuration of advanced items. NVDIMM Press [Enter] for configuration of advanced items. Memory MBIST Press [Enter] for configuration of advanced items. BIOS Setup - 92 -...
  • Page 93 5-3-3-1 DDR4 Common Options Parameter Description DDR4 Common Options Press [Enter] to configure the Plan of Record (POR) to enable / disable restrictions for DDR4 frequency and voltage programming. Memory speeds will be capped at AMD guidelines. Enforce POR Note: To enable 2 DIMMs per Channel at 3200MHz function, select [Accept] at warning message, change Overclock from [Auto] to [Enabled], and then set memory speed to 3200MHz.
  • Page 94 5-3-3-1-1 DRAM Controller Configuration Parameter Description DRAM Controller Configuration Press [Enter] to configure DRAM Power OptionsMa. Power Down Enable Š DRAM Power Options – Enable/Disable DDR power down mode. – Options available: Auto, Enabled, Disabled. Default setting is Auto. Selects the Cmd2T mode on ADDR/CMD. Cmd2T Options available: Auto, 1T, 2T.
  • Page 95 5-3-3-1-2 CAD Bus Configuration Parameter Description CAD Bus Configuration Setup time on CAD bus signals to Auto or Manual. CAD Bus Timing User Controls Options available: Auto/Manual. Default setting is Auto. CAD Bus Drive Strength User Drive Strength on CAD bus signals to Auto or Manual. Controls Options available: Auto/Manual.
  • Page 96 5-3-3-1-3 Data Bus Configuration Parameter Description Data Bus Configuration Data Bus Configuration User Specifies the mode for drive strength to Auto or Manual. Options available: Auto/Manual. Default setting is Auto. Controls BIOS Setup - 96 -...
  • Page 97 5-3-3-1-4 Common RAS Parameter Description Common RAS Enable/Disable the Data Poisoning function. Data Poisoning Options available: Auto, Enabled, Disabled. Default setting is Auto. Enable/Disable the DRAM Post Package Repair function. DRAM Post Package Repair Options available: Enabled/Disabled. Default setting is Auto. Enable/Disable the RCD Parity function.
  • Page 98 Parameter Description Disable Memory Error Injection Options available: False/True. Default setting is True. Press [Enter] to configure advanced items. DRAM ECC Symbol Size Š – Configures the DRAM ECC Symbol Size. – Options available: Auto, x4, x8, x16. Default setting is Auto. DRAM ECC Enable Š...
  • Page 99 5-3-3-1-5 Security Parameter Description Security Enable/Disable Transparent SME. TSME Options available: Auto, Enabled, Disabled. Default setting is Auto. Enable/Disable Data Scrambling. Data Scramble Options available: Auto, Enabled, Disabled. Default setting is Auto. - 45 - BIOS Setup...
  • Page 100 5-3-3-2 DRAM Memory Mapping Parameter Description DRAM Memory Mapping Interleave memory blocks across the DRAM chip selects for CPU 0. Chipselect Interleaving Options available: Auto/Disabled. Default setting is Auto. Configures the BankGroupSwap. BankGroupSwap (BGS) is a new memory mapping option in AGESA that alters how applications get assigned to BankGroupSwap physical locations within the memory modules.
  • Page 101 5-3-3-3 NVDIMM Parameter Description Disable NVDIMM-N feature for memory margin tool. NVDIMM Options available: No, Yes. Default setting is No. - 45 - BIOS Setup...
  • Page 102 5-3-3-4 Memory MBIST Parameter Description Memory MBIST Enable/Disable the Memory MBIST function. MBIST Enable Options available: Enabled/Disabled. Default setting is Disabled. Selects MBIST Test Mode. Interface Mode: Tests Single and Multiple CS transactions and Basic Connectivity. MBIST Test Mode (Note) Data Eye Mode: Measures Voltage vs.
  • Page 103 5-3-3-4-1 Data Eye Parameter Description Data Eye Pattern Select Options available: PRBS, SSO, Both. Default setting is PRBS. Pattern Length Determines the pattern length. The possible options are N=3..12. This item helps read the aggressors channels. Aggressor Channel Options available: Disabled, 1 Aggressor Channel, 3 Aggressor Channels, 7 Aggressor Channels.
  • Page 104 Parameter Description Target Static Lane Select This item is configurable when Target Static Lane Control is set to Upper 32 bits Enabled. Target Static Lane Select This item is configurable when Target Static Lane Control is set to Lower 32 bits Enabled.
  • Page 105: Nbio Common Options

    5-3-4 NBIO Common Options Parameter Description NBIO Common Options Enable/Disable the IOMMU function. IOMMU Options available: Enabled/Disabled. Default setting is Disabled. Enable/Disable Alternative Routng-ID Interpretation. PCIe ARI Support Options available: Auto, Enabled, Disabled. Default setting is Auto. Enable/Disable PCIe ten bit tags for supported devices. (Auto=Disabled) PCIe Ten Bit Tag Support Options available: Auto, Enabled, Disabled.
  • Page 106 Parameter Description Controls the Hot Plug Handling mode. Options available: Auto, A0 Mode, OS First (No Error Handling), Hot Plug Handling mode OS First (Error Handling-Not Implemented), Firmware First (Not Implemented). Default setting is Auto. Presence Detect Select Controls the Presence Detect Select mode. Options available: Auto, OR, AND.
  • Page 107 5-3-4-1 SMU Common Options Parameter Description SMU Common Options Power Policy Quick Options available: Standard, Best Performance, Energy Efficient. Setting Default setting is Standard. Selects use the fused Determinism or set customized Determinism. Determinism Control Options available: Auto/Manual. Default setting is Auto. Selects use the fused TDP or set customized TDP.
  • Page 108 Parameter Description Enable/Disable DF C-states. DF Cstates Options available: Auto, Enabled, Disabled. Default setting is Auto. Enable/Disable the CPPC feature. CPPC Options available: Auto, Enabled, Disabled. Default setting is Auto. Select HSMP support enable or disable. HSMP Support Options available: Auto, Enabled, Disabled. Default setting is Auto. Select Diagnostic Mode enable or disable.
  • Page 109 5-3-4-2 NBIO RAS Common Options Parameter Description NBIO RAS Common Options NBIO RAS Global Control Options available: Auto/Manual. Default setting is Auto. Options available: Disabled, MCA, Legacy. Default setting is MCA. NBIO RAS Control Configures the Egress Poison High Serverity. Each bit set to 1 enables Egress Poison Serverity High High serverity on the associated IOHC egress port.
  • Page 110 Parameter Description Uncorrected Converted to Enables mask for masking of uncorrectable parity errors on internal Poison Enabke Mask High arrays. Uncorrected Converted to Enables mask for masking of uncorrectable parity errors on internal Poison Enabke Mask Low arrays. System Hub Watchdog Timer Specifies the timer interval of the SYSHUB Watchdog timer in miliseconds. This item specifies whether SLINK read response errors are converted to SLINK Read Response OK an Okay response.
  • Page 111: Fch Common Options

    5-3-5 FCH Common Options Parameter Description FCH Common Options AC Power Loss Options Press [Enter] for configuration of advanced items. FCH RAS Options Press [Enter] for configuration of advanced items. - 45 - BIOS Setup...
  • Page 112 5-3-5-1 AC Power Loss Options Parameter Description AC Power Loss Options Selects the AC Loss Control Method. AC Loss Control Options available: Power Off, Power On, Last State. Default setting is Last State. BIOS Setup - 112 -...
  • Page 113 5-3-5-2 FCH RAS Options Parameter Description FCH RAS Options Enable/Disable the ALink RAS Support. ALink RAS Support Options available: Auto, Enabled, Disabled. Default setting is Auto. Enables AB to forward downstream sync-flood message to system Reset after sync flood controller. Options available: Auto, Enabled, Disabled.
  • Page 114: Ntb Common Options

    5-3-6 NTB Common Options Parameter Description NTB Common Options NTB Enable Options available: Auto/Enabled. Default setting is Auto. BIOS Setup - 114 -...
  • Page 115: Soc Miscellaneous Control

    5-3-7 SOC Miscellaneous Control Parameter Description SOC Miscellaneous Control Enable/Disable the ConsoleOut function for ABL. ABL Console Out Control Options available: Auto, Enabled, Disabled. Default setting is Auto. ABL PMU message To Control the total number of PMU debug messages. Options available: Auto, Enabled, Disabled.
  • Page 116: Amd Pbs Menu

    AMD PBS Menu AMD PBS Option menu displays submenu options for configuring the function of AMD PBS. Select a submenu item, then press [Enter] to access the related submenu screen. Parameter Description Press [Enter] for configuration of advanced items. Enable/Disable SPI Locking for protect ROM part. SPI Locking Options available: Enabled/Disabled.
  • Page 117: Ras

    5-4-1 RAS Parameter Description Enable/Disable the Periodic SMI for polling [MCA Threshold] error. RAS Periodic SMI Control Options available: Enabled/Disabled. Default setting is Enabled. SMI Threshold Configures the SMI Threshold value. SMI Scale Configures the SMI Scale value. Defines the unit of time scale. SMI Scale Unit Options available: millisecond, second, minute.
  • Page 118 Parameter Description PCIe Root Port UnCorr Err Initialize the PCIe AER Uncorrected Error Mask register of Root Port. Mask Reg PCIe Root Port UnCorr Err Initialize the PCIe AER Uncorrected Error Serverity register of Root Port. Sev Reg PCIe Device Corr Err Mask Initialize the PCIe AER Corrected Error Mask register of PCIe device.
  • Page 119: Chipset Setup Menu

    Chipset Setup Menu Chipset Setup menu displays submenu options for configuring the function of the North Bridge. Select a submenu item, then press <Enter> to access the related submenu screen. Parameter Description Configures the PCIe Link training in 1 or 2 steps. PCIe Link Training Type Options available: 1 Step/2Step.
  • Page 120: North Bridge

    5-5-1 North Bridge Parameter Description North Bridge Configuration Memory Information Total Memory Displays the total memory information. CPU0 Information Press [Enter] to view information related to CPU 0. BIOS Setup - 120 -...
  • Page 121: Fabric Resource

    5-5-2 Fabric Resource Parameter Description Fabric Resource Socket 0/1 NBIO_# PCIe Bus Change Socket 0/1 NBIO_# PCIe Bus Number. Number - 45 - BIOS Setup...
  • Page 122: Server Management Menu

    Server Management Menu Parameter Description Enable/Disable FRB-2 timer (POST timer). FRB-2 Timer Options available: Enabled/Disabled. Default setting is Enabled. Configures the FRB2 Timer timeout. FRB-2 Timer Options available: 3 minutes, 4 minutes, 5 minutes, 6 minutes. Default setting is 6 timeout minutes.
  • Page 123 Parameter Description System Event Log Press [Enter] to configure advanced items. View FRU Press [Enter] to view the FRU information. Information BMC network Press [Enter] to configure advanced items. configuration IPv6 BMC Network Press [Enter] to configure advanced items. Configuration - 45 - BIOS Setup...
  • Page 124: System Event Log

    5-6-1 System Event Log Parameter Description Enabling / Disabling Options Change this item to enable or disable all features of System Event SEL Components Logging during boot. Options available: Enabled/Disabled. Default setting is Enabled. Erasing Settings Choose options for erasing SEL. Erase SEL Options available: No/Yes, On next reset/Yes, On every reset.
  • Page 125: View Fru Information

    5-6-2 View FRU Information The FRU page is a simple display page for basic system ID information, as well as System product information. Items on this window are non-configurable. (Note) The model name will vary depends on the product you purchased - 45 - BIOS Setup...
  • Page 126: Bmc Network Configuration

    5-6-3 BMC Network Configuration Parameter Description BMC network configuration Lan Channel 1 Selects to configure LAN channel parameters statically or dynamically (DHCP). Do nothing option will not modify any BMC network parameters Configuration Address source during BIOS phase. Options available: Unspecified, Static, DynamicBmcDhcp. Default setting is DynamicBmcDhcp.
  • Page 127: Ipv6 Bmc Network Configuration

    5-6-4 IPv6 BMC Network Configuration Parameter Description IPv6 BMC network configuration IPv6 BMC Lan Channel 1 Enable/Disable IPv6 BMC LAN channel function. When this item is disabled, the system will not modify any BMC network during BIOS IPv6 BMC Lan Option phase.
  • Page 128: Security Menu

    Security Menu The Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. There are two types of passwords that you can set: • Administrator Password Entering this password will allow the user to access and change all settings in the Setup Utility. •...
  • Page 129: Secure Boot

    5-7-1 Secure Boot The Secure Boot submenu is applicable when your device is installed the Windows 8 (or above) operating ® system. Parameter Description System Mode Displays if the system is in User mode or Setup mode. Enable/ Disable the Secure Boot function. Secure Boot Options avaiable:Enabled/Disabled.
  • Page 130 Parameter Description Press [Enter] to configure advanced items. Please note that this item is configurable when Secure Boot Mode is set to Custom. Factory Key Provision Š – Allows to provision factory default Secure Boot keys when system is in Setup Mode.
  • Page 131: Boot Menu

    Boot Menu The Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. Parameter Description Boot Configuration Number of seconds to wait for setup activation key. 65535 (0xFFFF) Setup Prompt Timeout means indefinite waiting.
  • Page 132 Parameter Description FIXED BOOT ORDER Priorities Press [Enter] to configure the boot priority. By default, the server searches for boot devices in the following sequence: Hard drive. Boot Option #1 / #2 / #3 / #4 / #5 CD-COM/DVD drive. USB device.
  • Page 133: Uefi Network Drive Bbs Priorities

    5-8-1 UEFI NETWORK Drive BBS Priorities The UEFI network drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI network drives during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable.
  • Page 134: Uefi Application Boot Priorities

    5-8-2 UEFI Application Boot Priorities The UEFI application boot priorities submenu allows you to specify the boot device priority from the available UEFI applications during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. BIOS Setup - 134 -...
  • Page 135: Save & Exit Menu

    Save & Exit Menu The Save & Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press <Enter>. Parameter Description Save Options Saves changes made and closes the BIOS setup. Save Changes and Exit Options available: Yes/No.
  • Page 136: Abl Post Codes

    5-10 ABL POST Codes 5-10-1 StartProcessorTestPoints Entry used for range testing for @b Processor related TPs 0xE000 5-10-2 Memory test points Memory structure initialization (Public interface) 0xE001 SPD Data processing (Public interface) 0xE002 Memory configuration (Public interface) Phase 1 0xE003 DRAM initialization 0xE004 ProcMemSPDChecking...
  • Page 137: Original Post Code

    ABL Mem - PMU Stage Training Wr 2D 0xE023 ABL Mem - PMU Queue Empty 0xE024 ABL Mem - PMU US message Start 0xE025 ABL Mem - PMU US message End 0xE026 ABL Mem - PMU Complete 0xE027 ABL Mem - PMU - After PMU Training 0xE028 ABL Mem - PMU - Before Disable PMU 0xE029...
  • Page 138: Cpu Test Points

    ABL Mem - Before OtherTiming 0xE04A ABL Mem - Before UMAMemTyping 0xE04B ABL Mem - Before SetDqsEccTmgs 0xE04C ABL Mem - Before MemClr 0xE04D ABL Mem - Before On DIMM Thermal 0xE04E ABL Mem - Before DMI 0xE04F ABL MEM - End of phase 3 memory code 0xE050 5-10-5 CPU test points Entry point CPU init after training...
  • Page 139: Gnb Earlier Init

    5-10-8 Gnb Earlier init TP0x90 0xE090 GNB earlier interface 0xE091 GNB internal debug code 0xE092 GNB internal debug code 0xE093 GNB internal debug code 0xE094 GNB internal debug code 0xE095 GNB internal debug code 0xE096 GNB internal debug code 0xE097 GNB internal debug code 0xE098 GNB internal debug code...
  • Page 140 ABL 2 Begin 0xE0B8 ABL 2 Initialization 0xE0B9 ABL 2 After Training 0xE0BA ABL 2 Debug Synchronization 0xE0BB ABL 2 Error detected 0xE0BC ABL 2 Global memory error detected 0xE0BD ABL 2 End 0xE0BE ABL 3 Begin 0xE0BF ABL 3 Initialziation 0xE0C0 ABL 3 GMI/xGMI Initialization Stage 1 0xB1C0...
  • Page 141 ABL 4 APOB Initialzation - cold boot 0xE0CA ABL 4 Finalize memory settings - cold boot 0xE0CB ABL 4 CPU Initialize Optimized Boot - cold boot 0xE0CC ABL 4 Gmi Pcie Training - cold boot 0xE0CD ABL 4 Cold boot End 0xE0CE ABL 4 Initialization - Resume boot 0xE0CF...
  • Page 142: Pmu Test Points

    Before the memory code calls out to locate a buffer 0xE0F3 After the memory code calls out to locate a buffer 0xE0F4 Before the memory code calls out to locate a buffer 0xE0F5 After the memory code calls out to locate a buffer 0xE0F6 Before the memory code calls out to locate a buffer 0xE0F7...
  • Page 143 ABL Error for Soc Scan No Die error 0xE2AC ABL Error for Nb Tech Heap Aloc error 0xE2AD ABL Error for No Nb Constructor error 0xE2AE ABL Error for No Tech Constructor error 0xE2AE ABL Error for ABL1b Auto Alocation error 0xE2B0 ABL Error for ABL1b No NB Constructor error 0xE2B1...
  • Page 144 ABL Error over clock Mem Init Error 0xE2D5 ABL Error over clock Mem Other Error 0xE2D6 ABL Error for ABL6 General Error 0xE2D7 ABL Error Event Log Error 0xE2D8 ABL Error FATAL ABL1 Log Error 0xE2D9 ABL Error FATAL ABL2 Log Error 0xE2DA ABL Error FATAL ABL3 Log Error 0xE2DB...
  • Page 145 ABL Error ABL 2 Mem Init Error 0xE302 ABL Error ABL 4 Mem Init Error 0xE303 ABL Error ABL 6 Mem Init Error 0xE304 ABL Error ABL 1 error repor Error 0xE305 ABL Error ABL 2 error repor Error 0xE306 ABL Error ABL 3 error repor Error 0xE307 ABL Error ABL 4 error repor Error...
  • Page 146: Agesa Post Codes

    5-11 Agesa POST Codes 5-11-1 Universal Post Code Universal ACPI entry 0xA001 Universal ACPI exit 0xA002 Universal ACPI abort 0xA003 Universal SMBIOS entry 0xA004 Universal SMBIOS exit 0xA005 Universal SMBIOS abort 0xA006 5-11-2 [0xA1XX] For CZ only memory Postcodes Memory structure initialization (Public interface) 0xA101 SPD Data processing (Public interface) 0xA102...
  • Page 147 Calculate MaxRdLatency per channel 0xA120 TpProcMemReceiveDqsTraining 0xA121 Set Write Data delay 0xA122 Write test pattern 0xA123 Start read sweep 0xA124 Set Receive DQS delay 0xA125 Read Test pattern 0xA126 Compare Test pattern 0xA127 Update results 0xA128 Start Find passing window 0xA129 TpProcMemTransmitDqsTraining 0xA12A...
  • Page 148 Before InitMCT 0xA149 Before OtherTiming 0xA14A Before UMAMemTyping 0xA14B Before SetDqsEccTmgs 0xA14C Before MemClr 0xA14D Before On DIMM Thermal 0xA14E Before DMI 0xA14F End of memory code 0xA150 Entry point S3Init 0xA151 Sending MRS2 0xA180 Sedding MRS3 0xA181 Sending MRS1 0xA182 Sending MRS0 0xA183...
  • Page 149: S3 Interface Post Code

    BR Init Mid end 0xA19E BR Init Late entry 0xA19F BR Init Late install protocol 0xA1A0 BR Init Late end 0xA1A1 BR DXE install complete protocol 0xA1A2 UNB install complete PPI 0xA1A3 UNB AfterApLaunch callback entry 0xA1A4 UNB AfterApLaunch callback end 0xA1A5 5-11-3 S3 Interface Post Code Before the S3 save code calls out to allocate a buffer...
  • Page 150 PspSmmV1 SwSmiCallBack exit, build the S3 save area for resume 0xA511 PspSmmV1 BspSmmResumeVector entry 0xA512 PspSmmV1 BspSmmResumeVector exit 0xA513 PspSmmV1 ApSmmResumeVector entry 0xA514 PspSmmV1 ApSmmResumeVector exit 0xA515 PspP2CmboxV1 entry 0xA516 PspP2CmboxV1 exit 0xA517 // PSP V2 Modules PspPeiV2 entry 0xA521 PspPeiV2 exit 0xA522 PspDxeV2 entry...
  • Page 151 PspP2Cmbox Command SpiSetAttrib Handling entry 0xA592 PspP2Cmbox Command SpiGetBlockSize Handling entry 0xA593 PspP2Cmbox Command SpiReadFV Handling entry 0xA594 PspP2Cmbox Command SpiWriteFV Handling entry 0xA595 PspP2Cmbox Command SpiEraseFV Handling entry 0xA596 PspP2Cmbox Command Handling exit 0xA59E PspP2Cmbox Command Handling Fail exit 0xA59F // C2P mailbox Handling PSP C2P mailbox entry base [0xA5BX | Cmd]...
  • Page 152: 0Xa9Xx, 0Xaaxx] Assigned For Agesa Nbio Module

    5-11-6 [0xA9XX, 0xAAXX] assigned for AGESA NBIO Module // NbioBase AmdNbioBase PEIM driver entry 0xA900 AmdNbioBase PEIM driver exit 0xA901 AmdNbioBase DXE driver entry 0xA902 AmdNbioBase DXE driver exit 0xA903 // PCIe AmdNbioPcie PEIM driver entry 0xA904 AmdNbioPcie PEIM driver exit 0xA905 AmdNbioPcie DXE driver entry 0xA906...
  • Page 153 // APCB SMM APCB SMM Entry 0xA924 APCB SMM Exit 0xA925 // [0xA950, 0xA99F] NBIO PPI/PROTOCOL Callback NbioTopologyConfigureCallback entry 0xA950 NbioTopologyConfigureCallback exit 0xA951 MemoryConfigDoneCallbackPpi entry 0xA952 MemoryConfigDoneCallbackPpi exit 0xA953 DxioInitializationCallbackPpi entry 0xA954 DxioInitializationCallbackPpi exit 0xA955 DispatchSmuV9Callback entry 0xA956 DispatchSmuV9Callback exit 0xA957 DispatchSmuV10Callback entry 0xA958...
  • Page 154: 0Xacxx] Assigned For Agesa Ccx Module

    GfxConfigEnvInterface entry 0xA984 GfxConfigEnvInterface exit 0xA985 GfxEnvInterfaceCZ entry 0xA986 GfxEnvInterfaceCZ exit 0xA987 GfxMidInterfaceCZ entry 0xA988 GfxMidInterfaceCZ exit 0xA989 GfxIntInfoTableInterfaceCZ entry 0xA98A GfxIntInfoTableInterfaceCZ exit 0xA98B PcieMidInterfaceCZ entry 0xA98C PcieMidInterfaceCZ exit 0xA98D GnbMidInterfaceCZ entry 0xA98E GnbMidInterfaceCZ exit 0xA98F GnbSmuMidInterfaceCZ entry 0xA990 GnbSmuMidInterfaceCZ exit 0xA991 InvokeAmdInitLate entry 0xA992...
  • Page 155: 0Xadxx] Assigned For Agesa Df Module

    5-11-8 [0xADXX] assigned for AGESA DF Module DF PEI entry 0xAD50 DF DXE entry 0xAD55 DF Ready to Boot entry 0xAD56 DF PEI exit 0xADE0 DF DXE exit 0xADE5 DF Ready to Boot exit 0xADE6 5-11-9 [0xAFXX] assigned for AGESA FCH Module FCH InitReset dispatch point 0xAF01 FCH InitEnv dispatch point...
  • Page 156 FCH InitEnv AB Link 0xAF51 FCH InitEnv LPC 0xAF52 FCH InitEnv SPI 0xAF53 FCH InitEnv eSPI 0xAF54 FCH InitEnv SD 0xAF55 FCH InitEnv eMMC 0xAF56 FCH InitEnv SATA 0xAF57 FCH InitEnv USB 0xAF58 FCH InitEnv xGbE 0xAF59 FCH InitEnv HwAcpiP 0xAF5F FCH InitMid HwAcpi 0xAF60...
  • Page 157: Bios Post Beep Code (Ami Standard)

    5-12 BIOS POST Beep code (AMI standard) 5-12-1 PEI Beep Codes # of Beeps Description Memory not Installed. Memory was installed twice (InstallPeiMemory routine in PEI Core called twice) Recovery started DXEIPL was not found DXE Core Firmware Volume was not found Recovery failed S3 Resume failed Reset PPI is not available...
  • Page 158 This page intentionally left blank BIOS Setup - 158 -...

Table of Contents