5.
Maintenance
WarninG! Disconnect wrench
from air supply before changing
accessories, servicing or
performing maintenance.
replace or repair damaged parts.
Use genuine parts only.
Unauthorised parts may be
dangerous and will invalidate the
warranty.
5.1
if the air system does not have an
oiler lubricate the air wrench daily
with a few drops of Sealey air tool
oil dripped into the air inlet.
5.2
Check and top up the gearbox by
removing grub screw located under
the impact head.
5.3
Clean the wrench after use.
Do not use worn, or damaged sockets.
5.4
loss of power or erratic action may be due to the following:
a) Excessive drain on the air line. Moisture or restriction in the air pipe. incorrect size or
type of hose connectors. to remedy check the air supply and follow instructions in
chapter 3.
b) Grit or gum deposits in the wrench may also reduce performance. if your model has an
air strainer (located in the area of the air inlet), remove the strainer and clean it. Flush
the wrench out with gum solvent oil or an equal mixture of SAE no 10 oil and paraffin.
Allow to dry before use.
5.5
For a full service contact your local Sealey service agent.
5.6
When not in use, disconnect from air supply, clean wrench and store in a safe, dry,
childproof location.
the Gsa6002 Air impact Wrench, when operated in accordance with these instructions and tested in accordance with
En 28662-2: 1994 results in the following vibration emission declared in accordance with BS En12096: 1996.
Gsa6002 Measured vibration emission value: ..... 6.7m/s
these values are suitable for comparison with emission levels of other tools that have been subject to the same test.
this tool may cause hand-arm vibration syndrome if its use is inadequately managed.
recommended Measures to reduce risk of hand-arm vibration syndrome:
this tool should not be used by an individual regularly for more than 136 minutes in any 8 hour period.
this duration of use should be reduced if the individual is exposed to hand-arm vibration from other sources.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
iMPortant: no liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
inforMation: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
risk of Hand arm Vibration injury
2
sole uK Distributor, sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
iP32 7Ar
Original Language Version
uncertainty: ............................................. 2.7m/s
01284 757500
01284 703534
2
www.sealey.co.uk
Web
sales@sealey.co.uk
email
GSA6002 issue: 3 - 14/12/11

Advertisement

loading