5.2. Service Autotest Steps
STEPS
Control
Set program knob at position 3.
Push SW5 button.
Keeping SW5 button pushed,
turn program knob to position 1.
The
After 3 sec, SAU is shown in
Routine
display.
to
Enter
Then press Start/Pause button.
Servis
Machine enters to service
Autotest
autotest.
When knob positioned to
program 2, control steps starts.
Step 2
Dryer check Aquaswitch, if
(Knob
aquaswitch ON go to next step
Position
(pump activation), if aquaswitch
2)
OFF give water tank full error
Step 3
(Knob
Pump is on
Position
3)
Step 4
(Knob
Motor CCW (Tumble CW)-Motor
Position
stops
4)
HP T2touch PANEL
SERVICE MANUAL
Mini
mum
Step
Error
code
Dura
tion*
5 sec -
10sec
E03
5 sec
-
10
-
sec
CUSTOMER
SUPPORT
Led Indication Possible Errors
*Aquaswitch connector
is taken out
*Aquaswitch connector
-
is short circuit
*Styrofoam is borken or
not
Service must pour water
to pump reservoir and
check whether water is
pumped to tank.
-
If water is not pumped
to water tank;
*Pump connector is
taken out
Service must check
whether tumble is
moving to CW. If not;
*Motor connector is
-
taken out
*Motor might be locked
*Motor belt might be
dislocated